Honeywell LYNXR-2 manual To remotely activate X10 devices 07, To remotely bypass a zone

Page 10

QUICK VIEW OF SYSTEM FUNCTIONS

REMOTE PHONE CONTROL OPERATION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

To remotely disarm: ---------------------------------

 

 

 

 

 

 

 

 

+ [1]

 

 

 

 

 

 

 

 

 

 

To remotely arm in AWAY mode: --------------

 

 

 

 

 

 

 

 

+ [2]

 

 

 

 

 

 

 

 

 

 

To remotely arm in STAY mode: ---------------

 

 

 

 

 

 

 

 

+ [3]

 

 

 

 

 

 

 

 

 

 

To remotely arm in AWAY or STAY mode with NO DELAY:

 

 

 

 

 

 

 

 

 

 

 

 

+ [2] or [3] + [0]

To remotely activate X10 devices 01-06: ----

 

[#] + [4] + (2-digit) device no.

 

 

 

To remotely activate X10 devices 07 & 08:-

 

 

 

 

 

 

+ [#] + [4] + (2-digit) device no.

To remotely deactivate X10 devices 01-06: [#] + [7] + (2-digit) device no.

 

 

 

To remotely deactivate X10 devices 07 & 08:

 

 

 

 

 

 

 

+ [#] + [7] + (2-digit) device no.

To remotely bypass a zone: ----------------------

 

 

 

 

 

 

 

 

 

+ [6] + zone no.

 

 

 

To remotely activate forced bypass: ---------

 

 

 

 

 

 

 

+ [6] + [#]*

 

 

 

 

 

To remotely check system status: -------------

[*]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

To hang up: ----------------------------------------------

 

 

 

 

 

 

 

 

+ [9]

 

 

 

 

 

 

 

 

 

 

*If forced bypass was enabled by your installer.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OTHER FUNCTIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

To set the time and date:

 

 

 

 

 

 

 

 

 

+

 

 

 

 

 

 

 

 

 

 

 

+ [63]

 

 

 

 

 

 

 

 

 

 

FUNCTION

 

To set scheduling:

 

 

 

 

 

 

 

 

 

+

 

 

 

 

 

 

 

 

 

 

+ [64]

 

 

 

 

 

 

 

 

 

 

FUNCTION

 

To activate X10 devices 01-06:

 

 

 

 

 

 

 

 

 

+

 

 

 

 

 

 

 

 

 

+ (2-digit) dev. no.

 

 

FUNCTION

LIGHTS ON

 

To activate X10 devices 07 & 08:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+

FUNCTION

+

 

LIGHTS ON

+ (2-digit) dev. no.

To deactivate X10 devices 01-06:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FUNCTION

+

LIGHTS OFF

+ (2-digit) dev. no.

To deactivate X10 devices 07 & 08:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+

FUNCTION

 

+

LIGHTS OFF

+ (2-digit) dev. no.

To add a user code:

** +

 

 

 

+ user no. (02-08)+ user code

 

 

 

 

CODE

 

 

 

 

To delete a user code (except Master Code):

 

 

 

 

 

 

 

 

 

** +

 

 

 

 

+ user number (02-08)

 

 

 

 

 

 

 

 

 

CODE

To turn Test mode on:

 

 

 

 

 

 

 

 

 

+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TEST

 

 

 

 

To turn Test mode off:

 

 

 

 

 

 

 

 

 

+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

 

 

 

 

To use the defined AUX function: - Press and hold

 

 

 

key 2 seconds (4 beeps) +

 

AUX

 

To send message to pager:

Press and hold

 

 

key 2 seconds (4 beeps)

 

 

 

 

AUX

 

 

 

 

To program “Follow Me” reminder phone no:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+

FUNCTION

+ [65] + Enter up to 24

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

digits

To delete “Follow Me” reminder phone no:

** Only the master code can be used to add or delete another user code.

+ FUNCTION + [65]

– 10 –

Image 10
Contents LYNXR-2 Series Security System Page Table of Contents Page Features System OverviewLYNXR-2SIA False Alarm Prevention Features General Operation Two-Way Voice Feature Quick View of System Functions To remotely activate X10 devices To turn Test mode onTo turn Test mode off To remotely activate X10 devices 07About the Master Keypad GeneralMaster Keypad Definitions 2ARMED 3READYLights on / Lights OFF Keys Turns About the Display and Indicators LED MeaningsSecuring the Premises Checking System StatusRestarting Exit Delay While System Armed Arming in Stay ModeArming In Away Mode Exit Delay Restart/ResetTo arm with no Delay if Quick Arm is active Auto Stay FeatureArming the System with No Delay Quick ArmingEntry Delay Entry/Exit DelaysExit Delay LYNXR-2SIA Exit/Entry Delay TimesTo disarm the system and silence burglary alarms Memory of AlarmDisarming the System Forced Bypass Bypassing Protection ZonesBypassing Individual Zones Displaying Bypassed ZonesChime Mode Panic Keys / Chime ModePanic Keys Automatic Paging Paging FeatureUser Functions Code FormatSystem Announcements Follow Me Announcement FeatureFollow Me Reminder and System Announcements Reminder AnnouncementsTo program Follow Me reminder telephone number To delete Follow Me reminder telephone numberDevice Descriptions To deactivate X10 devices 07Message Playback Message Recording/Playback/Volume ControlRecording a Message Deleting MessagesTo adjust message playback/system announcement volume Adjusting the VolumeTo restore announcement sounding Function + Defining the AUX Function AUX FunctionPerforming the AUX function Minute Clock/CalendarHour MonthDay YearScheduling User Interface = the value that was last stored in the memory Schedule numberEnd Time minute Event Identifier Entries Entry Event CommentDay of Week Entries Entry DayUsing Remote Phone Control Feature Remote Phone Control FeatureEnter To remotely arm in Away mode Remote Phone Control Commands To remotely disarm systemTo remotely Bypass zones Speaker Phone Feature Using the Speaker Phone FeatureEntering # + Remote Services General Information Silencing a Fire AlarmCase of Fire Fire Alarm System Living Room BedroomEmergency Evacuation Security Codes System FunctionsTo Add/Delete a User or Change a Users Code Entering Test Mode Testing the System to be conducted weeklyExit Test Mode Typical Trouble Condition Displays Trouble MessagesRoutine Care Changing the LYNXR-2 Series System Battery Low Battery Conditions in Wireless SensorsMaintaining your system Summary of Audible Notification Sound Cause Display AnnouncementAdditional Announcements Federal Communications Commission FCC Part 15 Statement Industry CanadaFederal Communications Commission FCC Part Ringer Equivalence Number NoticeEvent of Telephone Operational Problems Servicing Information Page Owners Insurance Premium Credit Request Notifies Insert B = Burglary, F = FireOwners Insurance Premium Credit Request Limitations of this Alarm System Page Page Page Index No delay Pager ONE Year Limited Warranty ÊK15012yŠ

LYNXR-2 specifications

The Honeywell LYNXR-2 is an advanced wireless security system designed for residential and light commercial applications. Recognized for its user-friendly interface, the LYNXR-2 combines cutting-edge technology with essential security features, making it a popular choice among homeowners seeking peace of mind.

One of the primary characteristics of the LYNXR-2 is its sleek, modern design, which includes a large, easy-to-read touchscreen display. This intuitive interface allows users to manage their security system with minimal effort. From arming and disarming the system to viewing alerts, the touchscreen simplifies the interaction for users of all ages.

The LYNXR-2 employs Honeywell’s innovative technology, which integrates both security and home automation functionalities. This powerful system supports a wide range of wireless sensors, including door/window contacts, motion detectors, and smoke detectors. The flexibility of wireless technology means users can easily expand their security coverage without the need for complicated wiring.

Another notable feature of the LYNXR-2 is its built-in Z-Wave technology. This allows for seamless integration with smart home devices, enabling users to control lights, locks, and thermostats through the same interface. Home automation capabilities enhance security further by allowing users to program their system to perform specific actions, such as turning on lights when entering a home.

The LYNXR-2 system also offers robust communication features. It comes equipped with a cellular backup, ensuring that users remain connected to monitoring services even during power outages or if the phone line is cut. Additionally, the system supports both IP and cellular connectivity, providing flexibility in how users choose to connect their systems to monitoring services.

For those looking for added functionality, the LYNXR-2 can be easily integrated with Honeywell’s Total Connect Remote Services. This allows users to monitor and control their security system remotely through a smartphone or tablet, providing real-time notifications and updates on system status.

In summary, the Honeywell LYNXR-2 stands out for its combination of user-friendly features, advanced technologies, and extensive security and automation capabilities. It is an ideal solution for individuals seeking a reliable, scalable, and easy-to-use security system for their homes or light commercial properties. With its comprehensive features and seamless integration, the LYNXR-2 is poised to meet the security needs of modern living.