Bosch Appliances DVA-16K 4Hard Drive Numbering, Rear Panel Overview, 6Backplane Board

Page 12

12 en IntroductionRAID Subsystem DVA-16K Installation Manual

2.4.4Hard Drive Numbering

The front panel of the RAID subsystem enclosure houses sixteen (16) hard drives in a 4x4 con- figuration as shown in Figure 2.5. When viewed from the front, the drive bays (slots) are num- bered 1 to 16 from left to right, from top to bottom.

 

Fig. 2.5 Hard Drive Numbering

2.4.5

Rear Panel Overview

 

The rear section of RAID subsystem is accessed through the rear panel and is reserved for a

 

single RAID controller module, one (1) BBU, two (2) power supply units (PSUs) and two (2)

 

cooling modules.

 

The rear panel of the RAID subsystem described in this manual is shown in Figure 2.6. A

 

description of each rear panel component is given below:

Fig. 2.6 RAID subsystem Rear View

The rear panel shown in Figure 2.6 accommodates the following components:

RAID controller module: A controller board and a DDR RAM DIMM module are housed in the controller module to provide the system RAID functionalities. (See Section 2.5.3 The RAID Controller Module)

BBU: A BBU sustains cache memory during a power shortage to prevent data loss. (See Section 2.5.6 Battery Backup Unit (BBU))

PSUs: The hot-swappable PSUs provide power to the subsystem. A power switch is located on the right of each PSU to turn the system on and off. (See Section 2.5.7 Power Supply Units)

Cooling modules: The redundant cooling modules ventilate the subsystem to reduce the temperature within the subsystem. (See Section 2.5.8 Cooling Modules)

Dummy plate: This device is a single controller subsystem. The only controller module is installed in the upper controller bay. A dummy plate covers the lower controller bay at the rear of the subsystem.

2.4.6Backplane Board

Internal backplane boards separate the front and rear sections of the RAID subsystem. The PCB board provide logic level signals and low voltage power paths. They contain no user-ser- viceable components.

F.01U.027.799 V2 2008.08

Bosch Security System

Image 12
Contents RAID Subsystem DVA-16K Page Table of Contents 01U.027.799 V2 Bosch Security System Bosch Security System 01U.027.799 V2 Safety Precautions Precautions and InstructionsESD Precautions 1Warning3Certifications FCC Class B Radio Frequency Interference StatementIntroduction Product Overview2Management Controller Module Rear PanelBest Practices Enclosure ChassisPhysical Dimensions Front Panel Overview4Hard Drive Numbering Rear Panel Overview6Backplane Board Subsystem Components LCD PanelDrive Trays RAID Controller Module Controller Module Interfaces6Battery Backup Unit BBU Power Supply UnitsDimm Module Cooling Modules 11 PSU ModuleLED Indicators Audible AlarmsSubsystem Monitoring I2C busHot-swappable Components Hot-swap CapabilitiesComponents Normalized AirflowHardware Installation Installation PrerequisitesIntroduction Precautions and Instructions Static-free InstallationGeneral Installation Procedure Installation Procedure FlowchartStep Installation Procedure Done Unpacking the SubsystemRack/Cabinet Installation 7Drive Tray InstallationInstalling a Drive Tray Subsystem Monitoring Subsystem Monitoring OverviewStatus Indicating LEDs Brief Overview of the LEDsPower Name Color StatusPower Status 3Drive Tray LEDsController Module LEDs Name Color Status Drive BusyLED 5LAN Port LEDs BBU Module LEDPSU LEDs Name Color Status Online StatusCooling Module LEDs Color Status Flashing GreenStatic Green Static RedAudible Alarm Default Threshold ValuesFailed Devices 4Monitoring Subsystem Connection and Operation Scsi Connection OverviewScsi Cables Scsi Port on the Controller Rear PanelScsi Termination Host Connection Topology Single HostDual Hosts Dual ServerBosch Security System 01U.027.799 V2 Daisy Chain Procedures Daisy ChainDaisy Chain Topology Power On Power On ProcedureCheck List Power On Status Check 4LCD ScreenPower Off Procedure Modem Not ConfigInitializing… Please Wait 256MB RAM, Wait…Subsystem Maintenance About Subsystem MaintenanceGeneral Notes on Component Replacement OverviewController Module Maintenance Overview Replacing Controller Module ComponentsRemoving the Controller Module Levers 3Replacing the Controller ModuleInstalling the Controller Module Screws Dimm Module Replacement Dimm Module Replacement ProcedureDimm Module Considerations Installing the Dimm Module Replacing a Faulty BBU Module BBU Warnings and Precautions2Procedure Installing the BBU Module Replacing a Faulty PSU Module PSU Module Overview2Replacing the PSU Module PSUHandle 15 Installing the new PSU Module Cooling Module Maintenance Cooling Module OverviewReplacing a Cooling Module Page Hard Drive Maintenance Overview 7Replacing a Failed Hard DriveReplacing a Hard Drive 20 Drive Tray Key-lock RotationInstall the new hard drive Appendix Specifications Technical SpecificationsEnvironmental Specifications Power RequirementsSafety Requirements ShockVibration Controller Specifications SpecificationsDrive Tray Specifications Power Supply SpecificationsCooling Module Specifications RAID ManagementFault Tolerance Management Appendix Spare Parts and Accessories AccessoriesSpare Parts Model Name DescriptionAppendix Pin Outs Vhdci Scsi Port Pin OutsPin Name 2DB9 Audio Jack Pin Outs CN1 Pin Number Pin NameCN2 Pin Number Pin Name DB9 Audio Jack UPS Cable Pin Outs Null ModemUse this cable to connect the COM2 serial port to UPS Main Power Ethernet Port Pin OutsPin Pin Name 10Index En Index RAID Subsystem DVA-16K Installation Manual Page Bosch Security System

DVA-16K specifications

The Bosch Appliances DVA-16K is an exceptional range hood designed to enhance the cooking experience while providing effective ventilation in the kitchen. Known for its sleek and modern design, the DVA-16K integrates seamlessly with various kitchen decors while offering top-tier functionality.

One of its main features is the powerful 600 CFM blower that efficiently removes smoke, steam, and odors from the kitchen. This makes it an excellent choice for avid cooks who need a dependable ventilation solution during heavy-duty cooking sessions. The two-speed fan control allows users to easily adjust the ventilation power according to their cooking needs, ensuring optimal air quality without being overly loud.

The DVA-16K is also equipped with advanced ducted and ductless installation options, giving users flexibility based on their kitchen layout. The ducted installation ensures efficient venting to the outside, while the ductless option involves a recirculating system with charcoal filters to keep the air fresh. This versatility accommodates various kitchen designs and personal preferences.

The appliance features a stainless steel construction that not only adds a contemporary aesthetic but also ensures durability and easy maintenance. The surface is designed to resist fingerprints and smudges, making it easier to keep clean.

Another noteworthy characteristic of the Bosch DVA-16K is its integrated lighting system. The range hood comes with halogen lights that illuminate the cooking area effectively. This feature not only enhances visibility while cooking but also adds a touch of elegance to the kitchen environment.

In terms of noise levels, the Bosch DVA-16K operates quietly, which is a significant advantage when engaging in conversations or enjoying a peaceful cooking experience. Users can appreciate the balance of powerful airflow and reduced noise, making it a practical choice for modern kitchens.

Additionally, the DVA-16K is designed with easy-to-use controls, making the operation straightforward and convenient. The removable filters are dishwasher-safe, making cleaning a breeze and ensuring that the appliance continues to perform optimally over time.

Overall, the Bosch Appliances DVA-16K range hood is an outstanding combination of style, performance, and practicality. With its powerful ventilation capabilities, elegant design, and user-friendly features, it stands out as a top choice for homeowners seeking to elevate their kitchen experience.