Bosch Appliances DVA-16K Dimm Module, 6Battery Backup Unit BBU, Power Supply Units

Page 15

RAID Subsystem DVA-16K Installation ManualIntroduction en 15

2.5.5

DIMM Module

 

The controller module comes with a pre-installed 256MB capacity or above DDR RAM DIMM

 

module and can support capacities up to 1GB. The DIMM module is placed in an easily

 

accessed location on the controller board. However, when the DIMM module is being

 

changed, the controller module must be removed from the subsystem chassis.

2.5.6Battery Backup Unit (BBU)

The Li-ION battery backup unit (BBU) (see Figure 2.11) sustains cache memory after a power failure. It is installed on the upper left side of the controller module in the rear subsystem chassis.

 

Fig. 2.10 BBU Module

 

In accordance with international transportation regulations, the BBU is only charged to

 

between 35% and 45% of its total capacity when shipped. Therefore, after powering on the

 

subsystem (see Section 5.4 Power On) the BBU must be charged to its full capacity. It normally

 

requires approximately twelve (12) hours for the battery to be fully charged. If the battery is

 

not fully charged after twelve (12) hours, there is a problem with the BBU and you should con-

 

tact your subsystem vendor immediately. While the battery is being charged, the LED on the

 

BBU rear panel and the fifth LED on the rear panel of the controller module will flash slowly.

 

(See Section 4.2.6 BBU Module LED for details on the LED indicators.) You can check the sta-

 

tus of the battery’s charge via Bosch RAIDWatch or the firmware.

2.5.7

Power Supply Units

 

The RAID subsystem is equipped with two (2) redundant, hot-swappable, 460W PSUs, which

are located at the rear of the enclosure. (See Figure 2.6) The PSU is permanently mounted into a 2U (dual-level) bracket especially designed to house both the PSU and a cooling mod- ule, which is mounted in the lower part of the 2U bracket. Hot-swapping the PSU requires the removal of the cooling module.

As shown in Figure 2.11, each PSU comes with a single power socket for power cord plug-in, and a power switch on the right to turn the subsystem on and off. Two (2) embedded cooling fans provide sufficient airflow to keep the PSU cool. A single LED indicates the PSU status.

When any power supply failure occurs, such as over-voltage or fan failure, the LED shines red. A handle at the back of the PSU has been especially designed to enable you to remove the PSU from the subsystem while the subsystem is online. This should only be done if the PSU has failed and needs to be replaced.

A retention screw at the top of the PSU module secures the PSU to the enclosure. To remove the PSU, the retention screw must be removed first. When installing a new PSU module, make sure that the retention screw has been firmly secured.

Bosch Security System

F.01U.027.799 V2 2008.08

Image 15
Contents RAID Subsystem DVA-16K Page Table of Contents 01U.027.799 V2 Bosch Security System Bosch Security System 01U.027.799 V2 1Warning Safety PrecautionsPrecautions and Instructions ESD PrecautionsFCC Class B Radio Frequency Interference Statement 3CertificationsProduct Overview IntroductionController Module Rear Panel 2ManagementEnclosure Chassis Best PracticesFront Panel Overview Physical Dimensions4Hard Drive Numbering Rear Panel Overview6Backplane Board Subsystem Components LCD PanelDrive Trays Controller Module Interfaces RAID Controller Module6Battery Backup Unit BBU Power Supply UnitsDimm Module 11 PSU Module Cooling ModulesI2C bus LED IndicatorsAudible Alarms Subsystem MonitoringNormalized Airflow Hot-swappable ComponentsHot-swap Capabilities ComponentsHardware Installation Installation PrerequisitesIntroduction Static-free Installation Precautions and InstructionsUnpacking the Subsystem General Installation ProcedureInstallation Procedure Flowchart Step Installation Procedure Done7Drive Tray Installation Rack/Cabinet InstallationInstalling a Drive Tray Subsystem Monitoring Overview Subsystem MonitoringBrief Overview of the LEDs Status Indicating LEDsName Color Status PowerName Color Status Drive Busy Power Status3Drive Tray LEDs Controller Module LEDsLED Name Color Status Online Status 5LAN Port LEDsBBU Module LED PSU LEDsStatic Red Cooling Module LEDsColor Status Flashing Green Static GreenAudible Alarm Default Threshold ValuesFailed Devices 4Monitoring Scsi Port on the Controller Rear Panel Subsystem Connection and OperationScsi Connection Overview Scsi CablesScsi Termination Single Host Host Connection TopologyDual Server Dual HostsBosch Security System 01U.027.799 V2 Daisy Chain Procedures Daisy ChainDaisy Chain Topology Power On Power On ProcedureCheck List 4LCD Screen Power On Status Check256MB RAM, Wait… Power Off ProcedureModem Not Config Initializing… Please WaitOverview Subsystem MaintenanceAbout Subsystem Maintenance General Notes on Component ReplacementController Module Maintenance Overview Replacing Controller Module ComponentsRemoving the Controller Module 3Replacing the Controller Module LeversInstalling the Controller Module Screws Dimm Module Replacement Dimm Module Replacement ProcedureDimm Module Considerations Installing the Dimm Module Replacing a Faulty BBU Module BBU Warnings and Precautions2Procedure Installing the BBU Module Replacing a Faulty PSU Module PSU Module Overview2Replacing the PSU Module PSUHandle 15 Installing the new PSU Module Cooling Module Maintenance Cooling Module OverviewReplacing a Cooling Module Page 7Replacing a Failed Hard Drive Hard Drive Maintenance Overview20 Drive Tray Key-lock Rotation Replacing a Hard DriveInstall the new hard drive Power Requirements Appendix SpecificationsTechnical Specifications Environmental SpecificationsSafety Requirements ShockVibration Specifications Controller SpecificationsPower Supply Specifications Drive Tray SpecificationsRAID Management Cooling Module SpecificationsFault Tolerance Management Model Name Description Appendix Spare Parts and AccessoriesAccessories Spare PartsAppendix Pin Outs Vhdci Scsi Port Pin OutsPin Name 2DB9 Audio Jack Pin Outs CN1 Pin Number Pin NameCN2 Pin Number Pin Name DB9 Audio Jack UPS Cable Pin Outs Null ModemUse this cable to connect the COM2 serial port to UPS Main Power Ethernet Port Pin OutsPin Pin Name 10Index En Index RAID Subsystem DVA-16K Installation Manual Page Bosch Security System

DVA-16K specifications

The Bosch Appliances DVA-16K is an exceptional range hood designed to enhance the cooking experience while providing effective ventilation in the kitchen. Known for its sleek and modern design, the DVA-16K integrates seamlessly with various kitchen decors while offering top-tier functionality.

One of its main features is the powerful 600 CFM blower that efficiently removes smoke, steam, and odors from the kitchen. This makes it an excellent choice for avid cooks who need a dependable ventilation solution during heavy-duty cooking sessions. The two-speed fan control allows users to easily adjust the ventilation power according to their cooking needs, ensuring optimal air quality without being overly loud.

The DVA-16K is also equipped with advanced ducted and ductless installation options, giving users flexibility based on their kitchen layout. The ducted installation ensures efficient venting to the outside, while the ductless option involves a recirculating system with charcoal filters to keep the air fresh. This versatility accommodates various kitchen designs and personal preferences.

The appliance features a stainless steel construction that not only adds a contemporary aesthetic but also ensures durability and easy maintenance. The surface is designed to resist fingerprints and smudges, making it easier to keep clean.

Another noteworthy characteristic of the Bosch DVA-16K is its integrated lighting system. The range hood comes with halogen lights that illuminate the cooking area effectively. This feature not only enhances visibility while cooking but also adds a touch of elegance to the kitchen environment.

In terms of noise levels, the Bosch DVA-16K operates quietly, which is a significant advantage when engaging in conversations or enjoying a peaceful cooking experience. Users can appreciate the balance of powerful airflow and reduced noise, making it a practical choice for modern kitchens.

Additionally, the DVA-16K is designed with easy-to-use controls, making the operation straightforward and convenient. The removable filters are dishwasher-safe, making cleaning a breeze and ensuring that the appliance continues to perform optimally over time.

Overall, the Bosch Appliances DVA-16K range hood is an outstanding combination of style, performance, and practicality. With its powerful ventilation capabilities, elegant design, and user-friendly features, it stands out as a top choice for homeowners seeking to elevate their kitchen experience.