Bosch Appliances DVA-16K 1Warning, Safety Precautions, Precautions and Instructions

Page 6

6 en Warnings and CertificationsRAID Subsystem DVA-16K Installation Manual

1

Warnings and Certifications

1.1Warning

A shielded power cord is required in order to meet FCC emission limits and also to pre- vent interference with nearby radio and television reception.

Use only shielded cables to connect I/O devices to this equipment. You are cautioned that changes or modifications not expressly approved by the party responsible for com- pliance could void your authority to operate the equipment.

1.2

Safety Precautions

 

Precautions and Instructions

Prior to powering on the subsystem, ensure that the correct power range is being used. The subsystem comes with 16 drive bays. Leaving any of these drive bays empty will greatly affect the efficiency of the airflow within the enclosure, and will consequently lead to the system overheating, which can cause irreparable damage.

If a module fails, leave it in place until you have a replacement unit and you are ready to replace it.

Airflow Consideration: The subsystem requires an airflow clearance, especially at the front and rear.

Handle subsystem modules using the retention screws, eject levers, and the metal frames/face plates. Avoid touching PCB boards and connector pins.

To comply with safety, emission, or thermal requirements, none of the covers or replace- able modules should be removed. Make sure that all enclosure modules and covers are securely in place during operation.

Be sure that the rack cabinet into which the subsystem chassis will be installed provides sufficient ventilation channels and airflow circulation around the subsystem.

Provide a soft, clean surface to place your subsystem on before working on it. Servicing on a rough surface may damage the exterior of the chassis.

If it is necessary to transport the subsystem, repackage all drives and replaceable mod- ules separately.

Dual redundant controller models come with two controller modules that must be installed into the subsystem. Single controller modules come with a single controller module and a metal sheet is placed over the lower controller bay at the rear of the sub- system. Since single controller modules cannot be upgraded, this metal sheet should NEVER be removed.

ESD Precautions

Observe all conventional anti-ESD methods while handling system modules. The use of a grounded wrist strap and an anti-static work pad are recommended. Avoid dust and debris in your work area.

F.01U.027.799 V2 2008.08

Bosch Security System

Image 6
Contents RAID Subsystem DVA-16K Page Table of Contents 01U.027.799 V2 Bosch Security System Bosch Security System 01U.027.799 V2 ESD Precautions Safety PrecautionsPrecautions and Instructions 1Warning3Certifications FCC Class B Radio Frequency Interference StatementIntroduction Product Overview2Management Controller Module Rear PanelBest Practices Enclosure ChassisPhysical Dimensions Front Panel Overview4Hard Drive Numbering Rear Panel Overview6Backplane Board Subsystem Components LCD PanelDrive Trays RAID Controller Module Controller Module Interfaces6Battery Backup Unit BBU Power Supply UnitsDimm Module Cooling Modules 11 PSU ModuleSubsystem Monitoring LED IndicatorsAudible Alarms I2C busComponents Hot-swappable ComponentsHot-swap Capabilities Normalized AirflowHardware Installation Installation PrerequisitesIntroduction Precautions and Instructions Static-free InstallationStep Installation Procedure Done General Installation ProcedureInstallation Procedure Flowchart Unpacking the SubsystemRack/Cabinet Installation 7Drive Tray InstallationInstalling a Drive Tray Subsystem Monitoring Subsystem Monitoring OverviewStatus Indicating LEDs Brief Overview of the LEDsPower Name Color StatusController Module LEDs Power Status3Drive Tray LEDs Name Color Status Drive BusyLED PSU LEDs 5LAN Port LEDsBBU Module LED Name Color Status Online StatusStatic Green Cooling Module LEDsColor Status Flashing Green Static RedAudible Alarm Default Threshold ValuesFailed Devices 4Monitoring Scsi Cables Subsystem Connection and OperationScsi Connection Overview Scsi Port on the Controller Rear PanelScsi Termination Host Connection Topology Single HostDual Hosts Dual ServerBosch Security System 01U.027.799 V2 Daisy Chain Procedures Daisy ChainDaisy Chain Topology Power On Power On ProcedureCheck List Power On Status Check 4LCD ScreenInitializing… Please Wait Power Off ProcedureModem Not Config 256MB RAM, Wait…General Notes on Component Replacement Subsystem MaintenanceAbout Subsystem Maintenance OverviewController Module Maintenance Overview Replacing Controller Module ComponentsRemoving the Controller Module Levers 3Replacing the Controller ModuleInstalling the Controller Module Screws Dimm Module Replacement Dimm Module Replacement ProcedureDimm Module Considerations Installing the Dimm Module Replacing a Faulty BBU Module BBU Warnings and Precautions2Procedure Installing the BBU Module Replacing a Faulty PSU Module PSU Module Overview2Replacing the PSU Module PSUHandle 15 Installing the new PSU Module Cooling Module Maintenance Cooling Module OverviewReplacing a Cooling Module Page Hard Drive Maintenance Overview 7Replacing a Failed Hard DriveReplacing a Hard Drive 20 Drive Tray Key-lock RotationInstall the new hard drive Environmental Specifications Appendix SpecificationsTechnical Specifications Power RequirementsSafety Requirements ShockVibration Controller Specifications SpecificationsDrive Tray Specifications Power Supply SpecificationsCooling Module Specifications RAID ManagementFault Tolerance Management Spare Parts Appendix Spare Parts and AccessoriesAccessories Model Name DescriptionAppendix Pin Outs Vhdci Scsi Port Pin OutsPin Name 2DB9 Audio Jack Pin Outs CN1 Pin Number Pin NameCN2 Pin Number Pin Name DB9 Audio Jack UPS Cable Pin Outs Null ModemUse this cable to connect the COM2 serial port to UPS Main Power Ethernet Port Pin OutsPin Pin Name 10Index En Index RAID Subsystem DVA-16K Installation Manual Page Bosch Security System

DVA-16K specifications

The Bosch Appliances DVA-16K is an exceptional range hood designed to enhance the cooking experience while providing effective ventilation in the kitchen. Known for its sleek and modern design, the DVA-16K integrates seamlessly with various kitchen decors while offering top-tier functionality.

One of its main features is the powerful 600 CFM blower that efficiently removes smoke, steam, and odors from the kitchen. This makes it an excellent choice for avid cooks who need a dependable ventilation solution during heavy-duty cooking sessions. The two-speed fan control allows users to easily adjust the ventilation power according to their cooking needs, ensuring optimal air quality without being overly loud.

The DVA-16K is also equipped with advanced ducted and ductless installation options, giving users flexibility based on their kitchen layout. The ducted installation ensures efficient venting to the outside, while the ductless option involves a recirculating system with charcoal filters to keep the air fresh. This versatility accommodates various kitchen designs and personal preferences.

The appliance features a stainless steel construction that not only adds a contemporary aesthetic but also ensures durability and easy maintenance. The surface is designed to resist fingerprints and smudges, making it easier to keep clean.

Another noteworthy characteristic of the Bosch DVA-16K is its integrated lighting system. The range hood comes with halogen lights that illuminate the cooking area effectively. This feature not only enhances visibility while cooking but also adds a touch of elegance to the kitchen environment.

In terms of noise levels, the Bosch DVA-16K operates quietly, which is a significant advantage when engaging in conversations or enjoying a peaceful cooking experience. Users can appreciate the balance of powerful airflow and reduced noise, making it a practical choice for modern kitchens.

Additionally, the DVA-16K is designed with easy-to-use controls, making the operation straightforward and convenient. The removable filters are dishwasher-safe, making cleaning a breeze and ensuring that the appliance continues to perform optimally over time.

Overall, the Bosch Appliances DVA-16K range hood is an outstanding combination of style, performance, and practicality. With its powerful ventilation capabilities, elegant design, and user-friendly features, it stands out as a top choice for homeowners seeking to elevate their kitchen experience.