Bosch Appliances DVA-16K Hot-swappable Components, Hot-swap Capabilities, Normalized Airflow

Page 18

18 en IntroductionRAID Subsystem DVA-16K Installation Manual

2.7

Hot-swappable Components

2.7.1

Hot-swap Capabilities

 

The RAID subsystem comes with a number of hot-swappable components. A hot-swap compo-

 

nent is one that can be exchanged while the subsystem is still online without affecting the

 

operational integrity of the subsystem. These components should only be removed from the

 

subsystem when they are being replaced. At no other time should these components be

 

removed from the subsystem.

2.7.2

Components

 

The following components are hot-swappable:

 

Power supply units (PSUs)

 

Cooling modules

 

BBU

 

Hard drives

2.7.3

Normalized Airflow

 

Proper subsystem cooling is referred to as “normalized” airflow. Normalized airflow ensures

the sufficient cooling of the subsystem and is only attained when all components are properly installed. Therefore, a failed component should only be hot-swapped when a replacement is available. If a failed component is removed but not replaced, permanent damage to the sub- system can result.

F.01U.027.799 V2 2008.08

Bosch Security System

Image 18
Contents RAID Subsystem DVA-16K Page Table of Contents 01U.027.799 V2 Bosch Security System Bosch Security System 01U.027.799 V2 ESD Precautions Safety PrecautionsPrecautions and Instructions 1Warning3Certifications FCC Class B Radio Frequency Interference StatementIntroduction Product Overview2Management Controller Module Rear PanelBest Practices Enclosure ChassisPhysical Dimensions Front Panel Overview4Hard Drive Numbering Rear Panel Overview6Backplane Board Subsystem Components LCD PanelDrive Trays RAID Controller Module Controller Module Interfaces6Battery Backup Unit BBU Power Supply UnitsDimm Module Cooling Modules 11 PSU ModuleSubsystem Monitoring LED IndicatorsAudible Alarms I2C busComponents Hot-swappable ComponentsHot-swap Capabilities Normalized AirflowHardware Installation Installation PrerequisitesIntroduction Precautions and Instructions Static-free InstallationStep Installation Procedure Done General Installation ProcedureInstallation Procedure Flowchart Unpacking the SubsystemRack/Cabinet Installation 7Drive Tray InstallationInstalling a Drive Tray Subsystem Monitoring Subsystem Monitoring OverviewStatus Indicating LEDs Brief Overview of the LEDsPower Name Color StatusController Module LEDs Power Status3Drive Tray LEDs Name Color Status Drive BusyLED PSU LEDs 5LAN Port LEDsBBU Module LED Name Color Status Online StatusStatic Green Cooling Module LEDsColor Status Flashing Green Static RedAudible Alarm Default Threshold ValuesFailed Devices 4Monitoring Scsi Cables Subsystem Connection and OperationScsi Connection Overview Scsi Port on the Controller Rear PanelScsi Termination Host Connection Topology Single HostDual Hosts Dual ServerBosch Security System 01U.027.799 V2 Daisy Chain Procedures Daisy ChainDaisy Chain Topology Power On Power On ProcedureCheck List Power On Status Check 4LCD ScreenInitializing… Please Wait Power Off ProcedureModem Not Config 256MB RAM, Wait…General Notes on Component Replacement Subsystem MaintenanceAbout Subsystem Maintenance OverviewController Module Maintenance Overview Replacing Controller Module ComponentsRemoving the Controller Module Levers 3Replacing the Controller ModuleInstalling the Controller Module Screws Dimm Module Replacement Dimm Module Replacement ProcedureDimm Module Considerations Installing the Dimm Module Replacing a Faulty BBU Module BBU Warnings and Precautions2Procedure Installing the BBU Module Replacing a Faulty PSU Module PSU Module Overview2Replacing the PSU Module PSUHandle 15 Installing the new PSU Module Cooling Module Maintenance Cooling Module OverviewReplacing a Cooling Module Page Hard Drive Maintenance Overview 7Replacing a Failed Hard DriveReplacing a Hard Drive 20 Drive Tray Key-lock RotationInstall the new hard drive Environmental Specifications Appendix SpecificationsTechnical Specifications Power RequirementsSafety Requirements ShockVibration Controller Specifications SpecificationsDrive Tray Specifications Power Supply SpecificationsCooling Module Specifications RAID ManagementFault Tolerance Management Spare Parts Appendix Spare Parts and AccessoriesAccessories Model Name DescriptionAppendix Pin Outs Vhdci Scsi Port Pin OutsPin Name 2DB9 Audio Jack Pin Outs CN1 Pin Number Pin NameCN2 Pin Number Pin Name DB9 Audio Jack UPS Cable Pin Outs Null ModemUse this cable to connect the COM2 serial port to UPS Main Power Ethernet Port Pin OutsPin Pin Name 10Index En Index RAID Subsystem DVA-16K Installation Manual Page Bosch Security System

DVA-16K specifications

The Bosch Appliances DVA-16K is an exceptional range hood designed to enhance the cooking experience while providing effective ventilation in the kitchen. Known for its sleek and modern design, the DVA-16K integrates seamlessly with various kitchen decors while offering top-tier functionality.

One of its main features is the powerful 600 CFM blower that efficiently removes smoke, steam, and odors from the kitchen. This makes it an excellent choice for avid cooks who need a dependable ventilation solution during heavy-duty cooking sessions. The two-speed fan control allows users to easily adjust the ventilation power according to their cooking needs, ensuring optimal air quality without being overly loud.

The DVA-16K is also equipped with advanced ducted and ductless installation options, giving users flexibility based on their kitchen layout. The ducted installation ensures efficient venting to the outside, while the ductless option involves a recirculating system with charcoal filters to keep the air fresh. This versatility accommodates various kitchen designs and personal preferences.

The appliance features a stainless steel construction that not only adds a contemporary aesthetic but also ensures durability and easy maintenance. The surface is designed to resist fingerprints and smudges, making it easier to keep clean.

Another noteworthy characteristic of the Bosch DVA-16K is its integrated lighting system. The range hood comes with halogen lights that illuminate the cooking area effectively. This feature not only enhances visibility while cooking but also adds a touch of elegance to the kitchen environment.

In terms of noise levels, the Bosch DVA-16K operates quietly, which is a significant advantage when engaging in conversations or enjoying a peaceful cooking experience. Users can appreciate the balance of powerful airflow and reduced noise, making it a practical choice for modern kitchens.

Additionally, the DVA-16K is designed with easy-to-use controls, making the operation straightforward and convenient. The removable filters are dishwasher-safe, making cleaning a breeze and ensuring that the appliance continues to perform optimally over time.

Overall, the Bosch Appliances DVA-16K range hood is an outstanding combination of style, performance, and practicality. With its powerful ventilation capabilities, elegant design, and user-friendly features, it stands out as a top choice for homeowners seeking to elevate their kitchen experience.