6.7Replacing a Failed Hard Drive

Hard drives for the subsystem can be purchased separately. When purchasing the hard drives, the following factors should be considered:

Capacity (MB/GB): Use drives with the same capacity. RAID arrays use a “least-common- denominator” approach. The maximum capacity of each drive used in the array is the maxi- mum capacity of the smallest drive. Choose big drives with the same storage capacity. Profile: The drive trays and bays of the system are designed for 3.5-inch wide x 1-inch-high hard drives. It is highly recommended that you do not try to use drives of any other size. Drive type: The RAID subsystem described in this manual can use SATA-I or SATA-II hard drives. Please ensure that you purchase the correct hard drives.

CAUTION!

The hard drives and drive trays should only be installed into the subsystem after the subsys- tem has been mounted into a rack cabinet. If the hard drives are installed first, the subsystem will be too heavy to lift and the possible impact during installation may damage your drives.

CAUTION!

Handle hard drives with extreme care. Hard drives are very delicate. Dropping a drive onto a hard surface (even from a short distance) and hitting or touching the circuits on the drives with your tools may cause damage to the drives.

Observe all ESD prevention methods when installing drives.

Only use screws supplied with the drive canisters. Longer screws may damage the drive.

6.7.1

Hard Drive Maintenance Overview

Hot-swappable drive trays: The drive trays are all hot-swappable. If a hard drive fails, it can be replaced while the subsystem is still running.

Handles: If the failed hard drive is behind either the left or right front handle, unfold the handles to open the front access to the drive trays. (See Figure 6.19)

Fig. 6.19 Open the Front Handles

Open flap: Once the flap on the drive tray has been opened, the drive tray must be removed from the subsystem. Failure to remove the drive tray from the subsystem after the flap has been opened may cause data errors.

Remove drives slowly: When removing a drive tray from the RAID subsystem, pull the drive tray out only about one inch and then wait for at least 30 seconds for the hard drive motor to spin down before taking it out completely. Any impact to the hard drive while the drive motor is spinning can damage the drive.

Keep a replacement on hand: If a hard drive has failed, make sure you have a replacement hard drive readily available before removing the failed drive from the subsystem. Do not leave the drive tray slot open for an extended period of time or the normalized airflow will be disrupted and subsystem components will overheat and may become permanently damaged.

Bosch Security System

F.01U.027.799 V2 2008.08

Image 55
Contents RAID Subsystem DVA-16K Page Table of Contents 01U.027.799 V2 Bosch Security System Bosch Security System 01U.027.799 V2 1Warning Safety PrecautionsPrecautions and Instructions ESD PrecautionsFCC Class B Radio Frequency Interference Statement 3CertificationsProduct Overview IntroductionController Module Rear Panel 2ManagementEnclosure Chassis Best PracticesFront Panel Overview Physical DimensionsRear Panel Overview 4Hard Drive Numbering6Backplane Board LCD Panel Subsystem ComponentsDrive Trays Controller Module Interfaces RAID Controller ModulePower Supply Units 6Battery Backup Unit BBUDimm Module 11 PSU Module Cooling ModulesI2C bus LED IndicatorsAudible Alarms Subsystem MonitoringNormalized Airflow Hot-swappable ComponentsHot-swap Capabilities ComponentsInstallation Prerequisites Hardware InstallationIntroduction Static-free Installation Precautions and InstructionsUnpacking the Subsystem General Installation ProcedureInstallation Procedure Flowchart Step Installation Procedure Done7Drive Tray Installation Rack/Cabinet InstallationInstalling a Drive Tray Subsystem Monitoring Overview Subsystem MonitoringBrief Overview of the LEDs Status Indicating LEDsName Color Status PowerName Color Status Drive Busy Power Status3Drive Tray LEDs Controller Module LEDsLED Name Color Status Online Status 5LAN Port LEDsBBU Module LED PSU LEDsStatic Red Cooling Module LEDsColor Status Flashing Green Static GreenDefault Threshold Values Audible AlarmFailed Devices 4Monitoring Scsi Port on the Controller Rear Panel Subsystem Connection and OperationScsi Connection Overview Scsi CablesScsi Termination Single Host Host Connection TopologyDual Server Dual HostsBosch Security System 01U.027.799 V2 Daisy Chain Daisy Chain ProceduresDaisy Chain Topology Power On Procedure Power OnCheck List 4LCD Screen Power On Status Check256MB RAM, Wait… Power Off ProcedureModem Not Config Initializing… Please WaitOverview Subsystem MaintenanceAbout Subsystem Maintenance General Notes on Component ReplacementReplacing Controller Module Components Controller Module Maintenance OverviewRemoving the Controller Module 3Replacing the Controller Module LeversInstalling the Controller Module Screws Dimm Module Replacement Procedure Dimm Module ReplacementDimm Module Considerations Installing the Dimm Module BBU Warnings and Precautions Replacing a Faulty BBU Module2Procedure Installing the BBU Module PSU Module Overview Replacing a Faulty PSU Module2Replacing the PSU Module PSUHandle 15 Installing the new PSU Module Cooling Module Overview Cooling Module MaintenanceReplacing a Cooling Module Page 7Replacing a Failed Hard Drive Hard Drive Maintenance Overview20 Drive Tray Key-lock Rotation Replacing a Hard DriveInstall the new hard drive Power Requirements Appendix SpecificationsTechnical Specifications Environmental SpecificationsShock Safety RequirementsVibration Specifications Controller SpecificationsPower Supply Specifications Drive Tray SpecificationsRAID Management Cooling Module SpecificationsFault Tolerance Management Model Name Description Appendix Spare Parts and AccessoriesAccessories Spare PartsVhdci Scsi Port Pin Outs Appendix Pin OutsPin Name CN1 Pin Number Pin Name 2DB9 Audio Jack Pin OutsCN2 Pin Number Pin Name Null Modem DB9 Audio Jack UPS Cable Pin OutsUse this cable to connect the COM2 serial port to UPS Ethernet Port Pin Outs Main PowerPin Pin Name 10Index En Index RAID Subsystem DVA-16K Installation Manual Page Bosch Security System

DVA-16K specifications

The Bosch Appliances DVA-16K is an exceptional range hood designed to enhance the cooking experience while providing effective ventilation in the kitchen. Known for its sleek and modern design, the DVA-16K integrates seamlessly with various kitchen decors while offering top-tier functionality.

One of its main features is the powerful 600 CFM blower that efficiently removes smoke, steam, and odors from the kitchen. This makes it an excellent choice for avid cooks who need a dependable ventilation solution during heavy-duty cooking sessions. The two-speed fan control allows users to easily adjust the ventilation power according to their cooking needs, ensuring optimal air quality without being overly loud.

The DVA-16K is also equipped with advanced ducted and ductless installation options, giving users flexibility based on their kitchen layout. The ducted installation ensures efficient venting to the outside, while the ductless option involves a recirculating system with charcoal filters to keep the air fresh. This versatility accommodates various kitchen designs and personal preferences.

The appliance features a stainless steel construction that not only adds a contemporary aesthetic but also ensures durability and easy maintenance. The surface is designed to resist fingerprints and smudges, making it easier to keep clean.

Another noteworthy characteristic of the Bosch DVA-16K is its integrated lighting system. The range hood comes with halogen lights that illuminate the cooking area effectively. This feature not only enhances visibility while cooking but also adds a touch of elegance to the kitchen environment.

In terms of noise levels, the Bosch DVA-16K operates quietly, which is a significant advantage when engaging in conversations or enjoying a peaceful cooking experience. Users can appreciate the balance of powerful airflow and reduced noise, making it a practical choice for modern kitchens.

Additionally, the DVA-16K is designed with easy-to-use controls, making the operation straightforward and convenient. The removable filters are dishwasher-safe, making cleaning a breeze and ensuring that the appliance continues to perform optimally over time.

Overall, the Bosch Appliances DVA-16K range hood is an outstanding combination of style, performance, and practicality. With its powerful ventilation capabilities, elegant design, and user-friendly features, it stands out as a top choice for homeowners seeking to elevate their kitchen experience.