Bosch Appliances DVA-16K installation manual Cooling Modules, PSU Module

Page 16

16 en Introduction

RAID Subsystem DVA-16K Installation Manual

 

 

 

Fig. 2.11 PSU Module

 

For the PSU specifications, please refer to Section 7 Appendix: Specifications.

2.5.8

Cooling Modules

 

The RAID subsystem is equipped with two (2) 1U, dual-fan, redundant, hot-swappable cooling

 

modules. They are installed in the cooling module slots located in the lower section of the

PSU modules (see Figure 2.12.) The two (2) 9.7cm fans housed in each cooling module pro- vide two (2) fan speeds. When the subsystem is running in normal ambient temperature, the fans operate at the lower speed. When the temperature reaches the temperature threshold, the fans automatically change to high speed to generate more cooling air from the front to the rear of the subsystem to extract the heat generated by the hard drives.

Cooling module specifications are listed in Section 7 Appendix: Specifications.

Fig. 2.12 Cooling Module

F.01U.027.799 V2 2008.08

Bosch Security System

Image 16 Contents
RAID Subsystem DVA-16K Page Table of Contents 01U.027.799 V2 Bosch Security System Bosch Security System 01U.027.799 V2 Safety Precautions Precautions and InstructionsESD Precautions 1Warning3Certifications FCC Class B Radio Frequency Interference StatementIntroduction Product Overview2Management Controller Module Rear PanelBest Practices Enclosure ChassisPhysical Dimensions Front Panel Overview Rear Panel Overview 4Hard Drive Numbering 6Backplane Board LCD Panel Subsystem ComponentsDrive Trays RAID Controller Module Controller Module InterfacesPower Supply Units 6Battery Backup Unit BBUDimm Module Cooling Modules 11 PSU ModuleLED Indicators Audible AlarmsSubsystem Monitoring I2C busHot-swappable Components Hot-swap CapabilitiesComponents Normalized AirflowInstallation Prerequisites Hardware InstallationIntroduction Precautions and Instructions Static-free InstallationGeneral Installation Procedure Installation Procedure FlowchartStep Installation Procedure Done Unpacking the SubsystemRack/Cabinet Installation 7Drive Tray InstallationInstalling a Drive Tray Subsystem Monitoring Subsystem Monitoring OverviewStatus Indicating LEDs Brief Overview of the LEDsPower Name Color StatusPower Status 3Drive Tray LEDsController Module LEDs Name Color Status Drive BusyLED 5LAN Port LEDs BBU Module LEDPSU LEDs Name Color Status Online StatusCooling Module LEDs Color Status Flashing GreenStatic Green Static RedDefault Threshold Values Audible AlarmFailed Devices 4Monitoring Subsystem Connection and Operation Scsi Connection OverviewScsi Cables Scsi Port on the Controller Rear PanelScsi Termination Host Connection Topology Single HostDual Hosts Dual ServerBosch Security System 01U.027.799 V2 Daisy Chain Daisy Chain ProceduresDaisy Chain Topology Power On Procedure Power OnCheck List Power On Status Check 4LCD ScreenPower Off Procedure Modem Not ConfigInitializing… Please Wait 256MB RAM, Wait…Subsystem Maintenance About Subsystem MaintenanceGeneral Notes on Component Replacement OverviewReplacing Controller Module Components Controller Module Maintenance OverviewRemoving the Controller Module Levers 3Replacing the Controller ModuleInstalling the Controller Module Screws Dimm Module Replacement Procedure Dimm Module ReplacementDimm Module Considerations Installing the Dimm Module BBU Warnings and Precautions Replacing a Faulty BBU Module2Procedure Installing the BBU Module PSU Module Overview Replacing a Faulty PSU Module2Replacing the PSU Module PSUHandle 15 Installing the new PSU Module Cooling Module Overview Cooling Module MaintenanceReplacing a Cooling Module Page Hard Drive Maintenance Overview 7Replacing a Failed Hard DriveReplacing a Hard Drive 20 Drive Tray Key-lock RotationInstall the new hard drive Appendix Specifications Technical SpecificationsEnvironmental Specifications Power RequirementsShock Safety RequirementsVibration Controller Specifications SpecificationsDrive Tray Specifications Power Supply SpecificationsCooling Module Specifications RAID ManagementFault Tolerance Management Appendix Spare Parts and Accessories AccessoriesSpare Parts Model Name DescriptionVhdci Scsi Port Pin Outs Appendix Pin OutsPin Name CN1 Pin Number Pin Name 2DB9 Audio Jack Pin OutsCN2 Pin Number Pin Name Null Modem DB9 Audio Jack UPS Cable Pin OutsUse this cable to connect the COM2 serial port to UPS Ethernet Port Pin Outs Main PowerPin Pin Name 10Index En Index RAID Subsystem DVA-16K Installation Manual Page Bosch Security System