Bosch Appliances DVA-16K 5LAN Port LEDs, BBU Module LED, PSU LEDs, LAN Activity

Page 29

RAID Subsystem DVA-16K Installation ManualSubsystem Monitoring en 29

4.2.5LAN Port LEDs

A shielded Ethernet cable must be used to connect the RJ-45 Ethernet port to a hub on a net- work after you assign a permanent IP to the RAID subsystem. This enables you to manage your subsystem via the web. Two (2) LEDs located on the Ethernet port indicate the Ethernet con- nection status. See Figure 4.4 for the locations of the two (2) LED indicators. Refer to

Table 4.5 for the LED definitions.

Fig. 4.4 LAN Indicators

 

Name

Color

Status

 

 

 

 

 

Online Status

Green

ON indicates currently connected to a LAN

 

 

 

 

 

LAN Activity

Green

BLINKING indicates active transmission

 

 

 

 

 

Table 4.5 LAN Port LEDs Definitions

 

4.2.6

BBU Module LED

 

 

 

The BBU has an LED on the right side of the rear panel. (See Figure 4.5) The function is the

 

same as the fifth LED on the controller module. The LED is off when the BBU is functioning

normally and is able to sustain the cache memory. The LED flashes to indicate the BBU is charging. If the LED is illuminating amber, please re-charge the BBU or contact your system vendor to verify the problem.

 

Fig. 4.5 BBU Module LED

4.2.7

PSU LEDs

 

Each PSU comes with a single LED at the back (see Figure 4.6), located just above the power

 

switch that turns on the subsystem. This LED indicates the operational status of the PSU mod-

 

ule. Please refer to the PSU LED definitions shown in Table 4.6.

Fig. 4.6 PSU Module LED

Bosch Security System

F.01U.027.799 V2 2008.08

Image 29
Contents RAID Subsystem DVA-16K Page Table of Contents 01U.027.799 V2 Bosch Security System Bosch Security System 01U.027.799 V2 Precautions and Instructions Safety PrecautionsESD Precautions 1WarningFCC Class B Radio Frequency Interference Statement 3CertificationsProduct Overview IntroductionController Module Rear Panel 2ManagementEnclosure Chassis Best PracticesFront Panel Overview Physical Dimensions6Backplane Board 4Hard Drive NumberingRear Panel Overview Drive Trays Subsystem ComponentsLCD Panel Controller Module Interfaces RAID Controller ModuleDimm Module 6Battery Backup Unit BBUPower Supply Units 11 PSU Module Cooling ModulesAudible Alarms LED IndicatorsSubsystem Monitoring I2C busHot-swap Capabilities Hot-swappable ComponentsComponents Normalized AirflowIntroduction Hardware InstallationInstallation Prerequisites Static-free Installation Precautions and InstructionsInstallation Procedure Flowchart General Installation ProcedureStep Installation Procedure Done Unpacking the Subsystem7Drive Tray Installation Rack/Cabinet InstallationInstalling a Drive Tray Subsystem Monitoring Overview Subsystem MonitoringBrief Overview of the LEDs Status Indicating LEDsName Color Status Power3Drive Tray LEDs Power StatusController Module LEDs Name Color Status Drive BusyLED BBU Module LED 5LAN Port LEDsPSU LEDs Name Color Status Online StatusColor Status Flashing Green Cooling Module LEDsStatic Green Static RedFailed Devices Audible AlarmDefault Threshold Values 4Monitoring Scsi Connection Overview Subsystem Connection and OperationScsi Cables Scsi Port on the Controller Rear PanelScsi Termination Single Host Host Connection TopologyDual Server Dual HostsBosch Security System 01U.027.799 V2 Daisy Chain Topology Daisy Chain ProceduresDaisy Chain Check List Power OnPower On Procedure 4LCD Screen Power On Status CheckModem Not Config Power Off ProcedureInitializing… Please Wait 256MB RAM, Wait…About Subsystem Maintenance Subsystem MaintenanceGeneral Notes on Component Replacement OverviewRemoving the Controller Module Controller Module Maintenance OverviewReplacing Controller Module Components 3Replacing the Controller Module LeversInstalling the Controller Module Screws Dimm Module Considerations Dimm Module ReplacementDimm Module Replacement Procedure Installing the Dimm Module 2Procedure Replacing a Faulty BBU ModuleBBU Warnings and Precautions Installing the BBU Module 2Replacing the PSU Module Replacing a Faulty PSU ModulePSU Module Overview PSUHandle 15 Installing the new PSU Module Replacing a Cooling Module Cooling Module MaintenanceCooling Module Overview Page 7Replacing a Failed Hard Drive Hard Drive Maintenance Overview20 Drive Tray Key-lock Rotation Replacing a Hard DriveInstall the new hard drive Technical Specifications Appendix SpecificationsEnvironmental Specifications Power RequirementsVibration Safety RequirementsShock Specifications Controller SpecificationsPower Supply Specifications Drive Tray SpecificationsRAID Management Cooling Module SpecificationsFault Tolerance Management Accessories Appendix Spare Parts and AccessoriesSpare Parts Model Name DescriptionPin Name Appendix Pin OutsVhdci Scsi Port Pin Outs CN2 Pin Number Pin Name 2DB9 Audio Jack Pin OutsCN1 Pin Number Pin Name Use this cable to connect the COM2 serial port to UPS DB9 Audio Jack UPS Cable Pin OutsNull Modem Pin Pin Name Main PowerEthernet Port Pin Outs 10Index En Index RAID Subsystem DVA-16K Installation Manual Page Bosch Security System

DVA-16K specifications

The Bosch Appliances DVA-16K is an exceptional range hood designed to enhance the cooking experience while providing effective ventilation in the kitchen. Known for its sleek and modern design, the DVA-16K integrates seamlessly with various kitchen decors while offering top-tier functionality.

One of its main features is the powerful 600 CFM blower that efficiently removes smoke, steam, and odors from the kitchen. This makes it an excellent choice for avid cooks who need a dependable ventilation solution during heavy-duty cooking sessions. The two-speed fan control allows users to easily adjust the ventilation power according to their cooking needs, ensuring optimal air quality without being overly loud.

The DVA-16K is also equipped with advanced ducted and ductless installation options, giving users flexibility based on their kitchen layout. The ducted installation ensures efficient venting to the outside, while the ductless option involves a recirculating system with charcoal filters to keep the air fresh. This versatility accommodates various kitchen designs and personal preferences.

The appliance features a stainless steel construction that not only adds a contemporary aesthetic but also ensures durability and easy maintenance. The surface is designed to resist fingerprints and smudges, making it easier to keep clean.

Another noteworthy characteristic of the Bosch DVA-16K is its integrated lighting system. The range hood comes with halogen lights that illuminate the cooking area effectively. This feature not only enhances visibility while cooking but also adds a touch of elegance to the kitchen environment.

In terms of noise levels, the Bosch DVA-16K operates quietly, which is a significant advantage when engaging in conversations or enjoying a peaceful cooking experience. Users can appreciate the balance of powerful airflow and reduced noise, making it a practical choice for modern kitchens.

Additionally, the DVA-16K is designed with easy-to-use controls, making the operation straightforward and convenient. The removable filters are dishwasher-safe, making cleaning a breeze and ensuring that the appliance continues to perform optimally over time.

Overall, the Bosch Appliances DVA-16K range hood is an outstanding combination of style, performance, and practicality. With its powerful ventilation capabilities, elegant design, and user-friendly features, it stands out as a top choice for homeowners seeking to elevate their kitchen experience.