Bosch Appliances DVA-16K installation manual Name Color Status, Power

Page 26

26 en Subsystem Monitoring

RAID Subsystem DVA-16K Installation Manual

 

 

i

Three (3) LEDs monitor the status of the system. The definitions of these LEDs are given below.

Fig. 4.1

LCD Panel

 

 

 

 

 

Name

Color

Status

 

 

 

 

PWR

 

Blue

ON indicates that power is being supplied to the

(Power)

 

subsystem.

 

 

 

OFF indicates that no power is being supplied to the

 

 

 

subsystem.

 

 

 

 

BUSY

 

White

FLASHING indicates that there is activity on the

 

 

 

host/drive channels.

 

 

 

OFF indicates that there is no actively on the host/

 

 

 

drive channels.

 

 

 

 

ATTEN

 

Red

ON indicates that a component failure/status event

(Attention)

 

has occurred.

 

 

 

OFF indicates that the subsystem and all its compo-

 

 

 

nents are operating correctly.

 

 

 

 

Table 4.2

LCD Panel LED Definitions

 

NOTICE!

During the power up process, the LCD panel ATTEN LED will be turned on. If the subsystem boots up correctly, then the ATTEN LED will be turned off after the boot-up procedure is com- plete.

F.01U.027.799 V2 2008.08

Bosch Security System

Image 26
Contents RAID Subsystem DVA-16K Page Table of Contents 01U.027.799 V2 Bosch Security System Bosch Security System 01U.027.799 V2 ESD Precautions Safety PrecautionsPrecautions and Instructions 1Warning3Certifications FCC Class B Radio Frequency Interference StatementIntroduction Product Overview2Management Controller Module Rear PanelBest Practices Enclosure ChassisPhysical Dimensions Front Panel Overview6Backplane Board 4Hard Drive NumberingRear Panel Overview Drive Trays Subsystem ComponentsLCD Panel RAID Controller Module Controller Module InterfacesDimm Module 6Battery Backup Unit BBUPower Supply Units Cooling Modules 11 PSU ModuleSubsystem Monitoring LED IndicatorsAudible Alarms I2C busComponents Hot-swappable ComponentsHot-swap Capabilities Normalized AirflowIntroduction Hardware InstallationInstallation Prerequisites Precautions and Instructions Static-free InstallationStep Installation Procedure Done General Installation ProcedureInstallation Procedure Flowchart Unpacking the SubsystemRack/Cabinet Installation 7Drive Tray InstallationInstalling a Drive Tray Subsystem Monitoring Subsystem Monitoring OverviewStatus Indicating LEDs Brief Overview of the LEDsPower Name Color StatusController Module LEDs Power Status3Drive Tray LEDs Name Color Status Drive BusyLED PSU LEDs 5LAN Port LEDsBBU Module LED Name Color Status Online StatusStatic Green Cooling Module LEDsColor Status Flashing Green Static RedFailed Devices Audible AlarmDefault Threshold Values 4Monitoring Scsi Cables Subsystem Connection and OperationScsi Connection Overview Scsi Port on the Controller Rear PanelScsi Termination Host Connection Topology Single HostDual Hosts Dual ServerBosch Security System 01U.027.799 V2 Daisy Chain Topology Daisy Chain ProceduresDaisy Chain Check List Power OnPower On Procedure Power On Status Check 4LCD ScreenInitializing… Please Wait Power Off ProcedureModem Not Config 256MB RAM, Wait…General Notes on Component Replacement Subsystem MaintenanceAbout Subsystem Maintenance OverviewRemoving the Controller Module Controller Module Maintenance OverviewReplacing Controller Module Components Levers 3Replacing the Controller ModuleInstalling the Controller Module Screws Dimm Module Considerations Dimm Module ReplacementDimm Module Replacement Procedure Installing the Dimm Module 2Procedure Replacing a Faulty BBU ModuleBBU Warnings and Precautions Installing the BBU Module 2Replacing the PSU Module Replacing a Faulty PSU ModulePSU Module Overview PSUHandle 15 Installing the new PSU Module Replacing a Cooling Module Cooling Module MaintenanceCooling Module Overview Page Hard Drive Maintenance Overview 7Replacing a Failed Hard DriveReplacing a Hard Drive 20 Drive Tray Key-lock RotationInstall the new hard drive Environmental Specifications Appendix SpecificationsTechnical Specifications Power RequirementsVibration Safety RequirementsShock Controller Specifications SpecificationsDrive Tray Specifications Power Supply SpecificationsCooling Module Specifications RAID ManagementFault Tolerance Management Spare Parts Appendix Spare Parts and AccessoriesAccessories Model Name DescriptionPin Name Appendix Pin OutsVhdci Scsi Port Pin Outs CN2 Pin Number Pin Name 2DB9 Audio Jack Pin OutsCN1 Pin Number Pin Name Use this cable to connect the COM2 serial port to UPS DB9 Audio Jack UPS Cable Pin OutsNull Modem Pin Pin Name Main PowerEthernet Port Pin Outs 10Index En Index RAID Subsystem DVA-16K Installation Manual Page Bosch Security System

DVA-16K specifications

The Bosch Appliances DVA-16K is an exceptional range hood designed to enhance the cooking experience while providing effective ventilation in the kitchen. Known for its sleek and modern design, the DVA-16K integrates seamlessly with various kitchen decors while offering top-tier functionality.

One of its main features is the powerful 600 CFM blower that efficiently removes smoke, steam, and odors from the kitchen. This makes it an excellent choice for avid cooks who need a dependable ventilation solution during heavy-duty cooking sessions. The two-speed fan control allows users to easily adjust the ventilation power according to their cooking needs, ensuring optimal air quality without being overly loud.

The DVA-16K is also equipped with advanced ducted and ductless installation options, giving users flexibility based on their kitchen layout. The ducted installation ensures efficient venting to the outside, while the ductless option involves a recirculating system with charcoal filters to keep the air fresh. This versatility accommodates various kitchen designs and personal preferences.

The appliance features a stainless steel construction that not only adds a contemporary aesthetic but also ensures durability and easy maintenance. The surface is designed to resist fingerprints and smudges, making it easier to keep clean.

Another noteworthy characteristic of the Bosch DVA-16K is its integrated lighting system. The range hood comes with halogen lights that illuminate the cooking area effectively. This feature not only enhances visibility while cooking but also adds a touch of elegance to the kitchen environment.

In terms of noise levels, the Bosch DVA-16K operates quietly, which is a significant advantage when engaging in conversations or enjoying a peaceful cooking experience. Users can appreciate the balance of powerful airflow and reduced noise, making it a practical choice for modern kitchens.

Additionally, the DVA-16K is designed with easy-to-use controls, making the operation straightforward and convenient. The removable filters are dishwasher-safe, making cleaning a breeze and ensuring that the appliance continues to perform optimally over time.

Overall, the Bosch Appliances DVA-16K range hood is an outstanding combination of style, performance, and practicality. With its powerful ventilation capabilities, elegant design, and user-friendly features, it stands out as a top choice for homeowners seeking to elevate their kitchen experience.