First Alert K596-1 9 manual Checking System Status, Press the Status Key, System Can Be Armed

Page 13

6(&85,1*￿7+(￿35(0,6(6￿

Checking System Status

General Information

Before arming your system, all protected doors, windows, and other protection zones must be closed or

bypassed (see the

BYPASSING PROTECTION

section). Pressing the

STATUS

key will announce all zones

that are faulted, as well as any other abnormal system condition, making it easier for you to secure any open zones.

READY LIGHT:The green READY indicator on the keypad will be lit if the system is ready to be armed. If blinking, the system is not ready.

Press the STATUS

Key

Press the

STATUS

key once to announce the general status of the system. Depending on the current state of

the system the following phrases may be heard:

disarmed, ready to arm [message] [check system] disarmed, [not ready to arm], [message]

armed [away] [stay] [instant] [check system] [message]

NOTE: The phrases shown in brackets are variable, and are announced only if appropriate in the current state of the system.

Press the

STATUS

key a second time

to announce specific system status. Depending on the current state

of the system the following phrases may be heard:

fire alarm [zone voice descriptors] alarm [zone voice descriptors] fire fault [zone voice descriptors] fault [zone voice descriptors]

low battery [zone voice descriptor] system low battery

check system AC loss zones bypassed

chime

(second depression must be made within 10 seconds of the first)

VOLUME LEVEL:

The volume level of system announcements can be increased or decreased. Refer to the

MESSAGE RECORDING/PLAYBACK

section for the procedure.

 

 

System Can Be Armed

The READY LED will be lit once all protection zones have been closed or bypassed. You may now arm the system as usual.

– 13 –

Image 13
Contents 5HDG\*XDUG51 $%/2&217176 66702959 FeaturesGeneral Information Function section for detailed informationSecurity Codes General Operation OFF or until alarm bell timeout Two-Way Voice FeatureMemory of alarm display Announced, the siren sounds48,&.9,2667081&7,216 Volume AdjustmentSecurity Functions Message CenterTo remotely bypass a zone To remotely activate X-10 devicesTo remotely activate forced bypass To set schedulingGeneral About the Master KeypadBe repeated from its beginning Master Keypad DefinitionsKEY KeysKeys About the Display and Indicators Press the Status Key Checking System StatusSystem Can Be Armed PressArming In Away Mode Arming in Stay ModeArming the System To arm with no Delay Arming the System With No DelayQuick Arming ArmExit Delay Entry/Exit DelaysEntry Delay Exit AlarmsTo disarm the system and silence burglary alarms Memory of AlarmDisarming the System Police from a nearby safe locationBypassing Individual Zones Bypassing Protection ZonesForced Bypass Displaying Bypassed ZonesChime Mode Panic Keys / Chime ModePanic Keys Automatic Paging Paging FeatureCode Format Manual PagingTo activate X-10 devices Device DescriptionsTo deactivate X-10 devices To activate X-10 devices 7Adjusting the Volume Message Recording/Playback/Volume ControlRecording a Message Message PlaybackPerforming the AUX function Defining the AUX FunctionAM/PM Clock/CalendarScheduling User Interface Begin Time hour Event IdentifierBegin Time am/pm Begin Day Begin Time minuteEnd Time hour End Time am/pmEntry Event Event Identifier EntriesEntry Day Day of Week EntriesUsing Remote Phone Control Feature Remote Phone Control FeatureEnter To remotely arm in Away or Stay mode with no delay To remotely arm in Stay modeTo remotely disarm system To remotely deactivate X-10 devicesUsing the Speaker Phone Feature Speaker Phone FeatureSystem will not enter speaker phone mode if Speaker phone will be aborted ifSilencing a Fire Alarm $/$506670If InstalledGeneral Information Case of FireBasement $/$506670Determine two means of escape from each room. One path Emergency EvacuationEscape quickly dont panic Security Codes 667081&7,216To Add/Delete a User or Change a Users Code Add a user codeEntering Test Mode Testing the System to be conducted weeklyExit Test Mode When testing is completed, exit the Test mode by enteringTypical Trouble Condition Displays Trouble MessagesRoutine Care LOW BATChanging the ReadyGuard-REN System Battery Low Battery Conditions in Wireless SensorsTo silence Low Battery Warning Tones at the Keypad Maintaining your systemZones Bypassed System Low BatteryChime Radio Frequency Emissions Event of Telephone Operational ProblemsTELEPHONE/MODEM Interface General Information TestingFirst Alert Professionals ReadyGuard-REN Other Notifies Insert B = Burglary, F = FireFurnace Room Kitchen Basement Owners Insurance Premium Credit RequestFront Door 1st Floor Windows12, 38 Away ModeMaster User Rechargeable, Nickel-Metal Hydride BatteryAre not put in proper Or otDeath EverServicing Information Your security equipment or the Seller for product repair ONE Year Limited Warranty

1, K596-1 9 specifications

The First Alert K596-1 9,1 is a state-of-the-art smoke and carbon monoxide (CO) detector designed to enhance home safety. This innovative device combines advanced features and cutting-edge technology to provide reliable protection against two of the leading causes of accidental deaths in the home.

One of the standout features of the K596-1 is its **photoelectric smoke sensing technology**. This technology is particularly effective at detecting slow-smoldering fires, which typically produce larger particles of smoke. By using a light source and a sensor, the device can identify these particles quickly, thus reducing the likelihood of false alarms that are common with traditional ionization detectors.

In addition to smoke detection, the K596-1 also features a **carbon monoxide sensor**. CO is a colorless, odorless gas that can be fatal in high concentrations. The detector continuously monitors for this dangerous gas, providing peace of mind for families. If elevated levels are detected, the alarm will sound, alerting occupants to the potential danger.

The First Alert K596-1 is designed with **user-friendly features** in mind. An easy-to-read LED display provides real-time information on battery status and system functionality. The unit also includes a voice alert feature that announces the type of danger detected, whether smoke or carbon monoxide, making it easier for occupants to respond appropriately.

Battery life is another important characteristic of the K596-1. It utilizes a long-life battery that can last for several years, reducing the frequency of battery changes and ensuring that the device remains operational without constant maintenance. The easy-access battery compartment allows for a straightforward replacement when necessary.

Installation is simple, too, making the K596-1 accessible to users of all skill levels. The device can be mounted on walls or ceilings, and its compact design ensures that it blends seamlessly into any home environment.

In summary, the First Alert K596-1 9,1 is a crucial safety device that combines advanced detection capabilities with user-friendly features. Its photoelectric sensing technology and carbon monoxide detection work in tandem to provide comprehensive coverage against fire and gas hazards. With its easy installation and reliable performance, the K596-1 is a wise investment for anyone looking to enhance their home safety.