First Alert K596-1 9 manual Scheduling User Interface

Page 25

86(5￿)81&7,216￿

Scheduling User Interface

To access the Scheduling User Interface enter:

Master user code or

Installer Code

+

FUNCTION

+[64]

The following entries will be sequentially prompted to the user. Note that all inputs are checked for validity

upon entry and all invalid entries are rejected. Hitting a [*] will allow the entries to be accepted and advance to the next field. Hitting a [#] will reject the entry and back up one field. Hitting the [#] in the “Schedule Number” screen will exit the schedule programming.

NOTES:

1.

During the schedule programming, if three minutes passes and no key was entered, the programming

 

 

will be terminated and no values will be saved. Furthermore, if a zone is troubled while in schedule

 

 

programming, the system will abort the programming mode and show the troubled zone, and any

 

 

uncompleted program event will not be saved.

 

2.

It is not possible to enter the schedule programming mode from a wireless keypad (i.e. Ademco 5827)

 

3.

It is not possible to enter the schedule programming mode when either FC or CA is displayed on the

 

 

display.

Because the keypad display does not show prompt titles, you must refer to these instructions while programming the system. The prompts are indicated by a number/letter combination.

The prompts for option #64 are as follows:

 

 

 

 

n

 

 

 

 

 

 

 

 

 

 

 

 

 

i

d

 

 

 

 

 

 

 

 

 

 

 

 

:

A

b

 

 

 

 

 

 

 

 

 

 

 

b

:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b

d

 

 

 

 

 

 

 

 

 

 

 

 

:

A

E

 

 

 

 

 

 

 

 

 

 

 

E

:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E

d

 

 

 

 

 

Schedule number-------------

for selecting a schedule number (1-8)

Event identifier---------------

for selecting a schedule action (0-5)

Begin time (hrs, am/pm)----

for selecting a schedule begin time (hour, am/pm)

 

entry (00-12)

Begin time (min)-------------

for selecting a schedule begin time (minute)

 

entry (00-59)

Begin day---------------------

for selecting a schedule begin day (01-17)

End time (hrs, am/pm)------

for selecting a schedule end time (hour, am/pm)

 

entry (00-12)

End time (min)---------------

for selecting a schedule end time (minute)

 

entry (00-59)

End day------------------------

for selecting a schedule end day (01-17)

d

n

Device number---------------

for selecting a X-10 device number (1-8)

– 25 –

Image 25
Contents 5HDG\*XDUG51 $%/2&217176 66702959 FeaturesGeneral Information Function section for detailed informationSecurity Codes General Operation OFF or until alarm bell timeout Two-Way Voice FeatureMemory of alarm display Announced, the siren sounds48,&.9,2667081&7,216 Volume AdjustmentSecurity Functions Message CenterTo remotely bypass a zone To remotely activate X-10 devicesTo remotely activate forced bypass To set schedulingGeneral About the Master KeypadBe repeated from its beginning Master Keypad DefinitionsKEY KeysKeys About the Display and Indicators Press the Status Key Checking System StatusSystem Can Be Armed PressArming In Away Mode Arming in Stay ModeArming the System To arm with no Delay Arming the System With No DelayQuick Arming ArmExit Delay Entry/Exit DelaysEntry Delay Exit AlarmsTo disarm the system and silence burglary alarms Memory of AlarmDisarming the System Police from a nearby safe locationBypassing Individual Zones Bypassing Protection ZonesForced Bypass Displaying Bypassed ZonesChime Mode Panic Keys / Chime ModePanic Keys Automatic Paging Paging FeatureCode Format Manual PagingTo activate X-10 devices Device DescriptionsTo deactivate X-10 devices To activate X-10 devices 7Adjusting the Volume Message Recording/Playback/Volume ControlRecording a Message Message PlaybackPerforming the AUX function Defining the AUX FunctionAM/PM Clock/CalendarScheduling User Interface Begin Time hour Event IdentifierBegin Time am/pm Begin Day Begin Time minuteEnd Time hour End Time am/pmEntry Event Event Identifier EntriesEntry Day Day of Week EntriesUsing Remote Phone Control Feature Remote Phone Control FeatureEnter To remotely arm in Away or Stay mode with no delay To remotely arm in Stay modeTo remotely disarm system To remotely deactivate X-10 devicesUsing the Speaker Phone Feature Speaker Phone FeatureSystem will not enter speaker phone mode if Speaker phone will be aborted ifSilencing a Fire Alarm $/$506670If InstalledGeneral Information Case of FireBasement $/$506670Determine two means of escape from each room. One path Emergency EvacuationEscape quickly dont panic Security Codes 667081&7,216To Add/Delete a User or Change a Users Code Add a user codeEntering Test Mode Testing the System to be conducted weeklyExit Test Mode When testing is completed, exit the Test mode by enteringTypical Trouble Condition Displays Trouble MessagesRoutine Care LOW BATChanging the ReadyGuard-REN System Battery Low Battery Conditions in Wireless SensorsTo silence Low Battery Warning Tones at the Keypad Maintaining your systemZones Bypassed System Low BatteryChime Radio Frequency Emissions Event of Telephone Operational ProblemsTELEPHONE/MODEM Interface General Information TestingFirst Alert Professionals ReadyGuard-REN Other Notifies Insert B = Burglary, F = FireFurnace Room Kitchen Basement Owners Insurance Premium Credit RequestFront Door 1st Floor Windows12, 38 Away ModeMaster User Rechargeable, Nickel-Metal Hydride BatteryAre not put in proper Or otDeath EverServicing Information Your security equipment or the Seller for product repair ONE Year Limited Warranty

1, K596-1 9 specifications

The First Alert K596-1 9,1 is a state-of-the-art smoke and carbon monoxide (CO) detector designed to enhance home safety. This innovative device combines advanced features and cutting-edge technology to provide reliable protection against two of the leading causes of accidental deaths in the home.

One of the standout features of the K596-1 is its **photoelectric smoke sensing technology**. This technology is particularly effective at detecting slow-smoldering fires, which typically produce larger particles of smoke. By using a light source and a sensor, the device can identify these particles quickly, thus reducing the likelihood of false alarms that are common with traditional ionization detectors.

In addition to smoke detection, the K596-1 also features a **carbon monoxide sensor**. CO is a colorless, odorless gas that can be fatal in high concentrations. The detector continuously monitors for this dangerous gas, providing peace of mind for families. If elevated levels are detected, the alarm will sound, alerting occupants to the potential danger.

The First Alert K596-1 is designed with **user-friendly features** in mind. An easy-to-read LED display provides real-time information on battery status and system functionality. The unit also includes a voice alert feature that announces the type of danger detected, whether smoke or carbon monoxide, making it easier for occupants to respond appropriately.

Battery life is another important characteristic of the K596-1. It utilizes a long-life battery that can last for several years, reducing the frequency of battery changes and ensuring that the device remains operational without constant maintenance. The easy-access battery compartment allows for a straightforward replacement when necessary.

Installation is simple, too, making the K596-1 accessible to users of all skill levels. The device can be mounted on walls or ceilings, and its compact design ensures that it blends seamlessly into any home environment.

In summary, the First Alert K596-1 9,1 is a crucial safety device that combines advanced detection capabilities with user-friendly features. Its photoelectric sensing technology and carbon monoxide detection work in tandem to provide comprehensive coverage against fire and gas hazards. With its easy installation and reliable performance, the K596-1 is a wise investment for anyone looking to enhance their home safety.