First Alert K596-1 9 manual General Operation

Page 5

￿

6<67(0￿29(59,(:￿

General Operation

Zones

Your system's sensing devices have been assigned to various "zones." For example, the sensing device on your entry/exit door may have been assigned to zone 01, sensing devices on windows in the master bedroom

to zone 02, and so on. These numbers appear on the display when an alarm or trouble condition occurs.

8/￿

ReadyGuard-REN is not intended for UL985 Household Fire applications unless a 24-hour

backup battery (P/N LYNXRCHKIT-HC) is installed.

 

Fire Protection

 

 

The fire protection portion of your security system (if used) is always active and

will sound an alarm if a

fire condition is detected. Refer to the

FIRE ALARM SYSTEM

section for important information concerning

fire protection, smoke detectors and planning emergency exit routes from the premises.

Burglary Protection

Your system provides two modes of burglary protection: STAY and AWAY. STAY mode protects the perimeter only, allowing you to freely move within inside the premises. AWAY mode protects the entire system. Both modes provide an entry delay time that allows you to reenter the premises without setting off an alarm. For additional security, you can turn the entry delay off when arming the system by using the

NO DELAY

key in combination with the desired arming key. The system also allows you to bypass selected

zones before arming the system,

if desired. Refer

to the

BYPASSING

PROTECTION ZONES

section. The

system also provides a CHIME mode, for alerting

users to

the opening of protected doors

and windows

 

while the system is disarmed.

 

 

 

 

 

You must turn on ("arm") the

burglary protection portion of your system before it will sense burglary

 

alarms. To arm the system, enter your user code then press the desired arming key (AWAY or STAY).

 

Refer to the

ARMING THE SYSTEM

 

section for detailed procedures and information.

 

Security Codes

At the time of installation, you were assigned a personal 4-digit security or “master user” code. You must enter the user code when arming and disarming the system, and when performing other system functions. As

an additional security feature, other users who

do not need to know your code can be assigned up to 6

different security codes. Refer to the

SECURITY CODES

section for procedures on adding security codes to

the system.

 

 

Alarms

When an alarm occurs, the keypad and external sounders will sound for about 15-seconds, and the keypad

will display the zone(s) causing the alarm. After 15-seconds, the siren stops temporarily and voice

– 5 –

Image 5
Contents 5HDG\*XDUG51 $%/2&217176 66702959 FeaturesGeneral Information Function section for detailed informationSecurity Codes General Operation OFF or until alarm bell timeout Two-Way Voice FeatureMemory of alarm display Announced, the siren sounds48,&.9,2667081&7,216 Volume AdjustmentSecurity Functions Message CenterTo remotely bypass a zone To remotely activate X-10 devicesTo remotely activate forced bypass To set schedulingGeneral About the Master KeypadBe repeated from its beginning Master Keypad DefinitionsKeys KeysKEY About the Display and Indicators Press the Status Key Checking System StatusSystem Can Be Armed PressArming the System Arming in Stay ModeArming In Away Mode To arm with no Delay Arming the System With No DelayQuick Arming ArmExit Delay Entry/Exit DelaysEntry Delay Exit AlarmsTo disarm the system and silence burglary alarms Memory of AlarmDisarming the System Police from a nearby safe locationBypassing Individual Zones Bypassing Protection ZonesForced Bypass Displaying Bypassed ZonesPanic Keys Panic Keys / Chime ModeChime Mode Automatic Paging Paging FeatureCode Format Manual PagingTo activate X-10 devices Device DescriptionsTo deactivate X-10 devices To activate X-10 devices 7Adjusting the Volume Message Recording/Playback/Volume ControlRecording a Message Message PlaybackPerforming the AUX function Defining the AUX FunctionAM/PM Clock/CalendarScheduling User Interface Begin Time am/pm Event IdentifierBegin Time hour Begin Day Begin Time minuteEnd Time hour End Time am/pmEntry Event Event Identifier EntriesEntry Day Day of Week EntriesEnter Remote Phone Control FeatureUsing Remote Phone Control Feature To remotely arm in Away or Stay mode with no delay To remotely arm in Stay modeTo remotely disarm system To remotely deactivate X-10 devicesUsing the Speaker Phone Feature Speaker Phone FeatureSystem will not enter speaker phone mode if Speaker phone will be aborted ifSilencing a Fire Alarm $/$506670If InstalledGeneral Information Case of FireBasement $/$506670Escape quickly dont panic Emergency EvacuationDetermine two means of escape from each room. One path Security Codes 667081&7,216To Add/Delete a User or Change a Users Code Add a user codeEntering Test Mode Testing the System to be conducted weeklyExit Test Mode When testing is completed, exit the Test mode by enteringTypical Trouble Condition Displays Trouble MessagesRoutine Care LOW BATChanging the ReadyGuard-REN System Battery Low Battery Conditions in Wireless SensorsTo silence Low Battery Warning Tones at the Keypad Maintaining your systemChime System Low BatteryZones Bypassed TELEPHONE/MODEM Interface Event of Telephone Operational ProblemsRadio Frequency Emissions General Information TestingFirst Alert Professionals ReadyGuard-REN Other Notifies Insert B = Burglary, F = FireFurnace Room Kitchen Basement Owners Insurance Premium Credit RequestFront Door 1st Floor Windows12, 38 Away ModeMaster User Rechargeable, Nickel-Metal Hydride BatteryAre not put in proper Or otDeath EverServicing Information Your security equipment or the Seller for product repair ONE Year Limited Warranty

1, K596-1 9 specifications

The First Alert K596-1 9,1 is a state-of-the-art smoke and carbon monoxide (CO) detector designed to enhance home safety. This innovative device combines advanced features and cutting-edge technology to provide reliable protection against two of the leading causes of accidental deaths in the home.

One of the standout features of the K596-1 is its **photoelectric smoke sensing technology**. This technology is particularly effective at detecting slow-smoldering fires, which typically produce larger particles of smoke. By using a light source and a sensor, the device can identify these particles quickly, thus reducing the likelihood of false alarms that are common with traditional ionization detectors.

In addition to smoke detection, the K596-1 also features a **carbon monoxide sensor**. CO is a colorless, odorless gas that can be fatal in high concentrations. The detector continuously monitors for this dangerous gas, providing peace of mind for families. If elevated levels are detected, the alarm will sound, alerting occupants to the potential danger.

The First Alert K596-1 is designed with **user-friendly features** in mind. An easy-to-read LED display provides real-time information on battery status and system functionality. The unit also includes a voice alert feature that announces the type of danger detected, whether smoke or carbon monoxide, making it easier for occupants to respond appropriately.

Battery life is another important characteristic of the K596-1. It utilizes a long-life battery that can last for several years, reducing the frequency of battery changes and ensuring that the device remains operational without constant maintenance. The easy-access battery compartment allows for a straightforward replacement when necessary.

Installation is simple, too, making the K596-1 accessible to users of all skill levels. The device can be mounted on walls or ceilings, and its compact design ensures that it blends seamlessly into any home environment.

In summary, the First Alert K596-1 9,1 is a crucial safety device that combines advanced detection capabilities with user-friendly features. Its photoelectric sensing technology and carbon monoxide detection work in tandem to provide comprehensive coverage against fire and gas hazards. With its easy installation and reliable performance, the K596-1 is a wise investment for anyone looking to enhance their home safety.