First Alert 1 66702959, Features, General Information, Function section for detailed information

Page 3

6<67(0￿29(59,(:￿

Features

General Information

This system offers you three forms of protection: burglary, fire, and emergency, depending on the configuration of your system. The system consists of a master keypad for controlling system operation, various wireless sensors that provide perimeter and interior burglary protection, and optional smoke or combustion detectors to provide early fire warning. In addition, optional wireless keypads may have been installed to allow you to control the system away from the master keypad. The system may also be controlled from a remote telephone and can be used as a speaker phone.

The system uses microcomputer technology to monitor all protection zones and system status, display appropriate information on the keypad display, and initiate appropriate alarms. Your system may also have been programmed to automatically send alarm or status messages over the phone lines to a central alarm monitoring station, and may also be capable of two-way voice communication with the central station.

The user features of this security system are listed below. Ask your installer which features have been programmed for your system.

STAY and AWAY arming modes:By using these modes you can protect either the perimeter only, or the entire premises.

3 panic key functions: Designated keys allow you to manually activate fire, personal emergency, or

silent alarms. Refer to the

PANIC KEYS

section for detailed information.

Paging feature: Alerts you to certain system conditions by displaying code numbers that indicate the type of condition that has occurred. In addition, pressing the AUX key can send a predefined message to

your pager, if programmed to do so (see AUX key function below). Refer to the

PAGING FEATURE

section for detailed information.

 

Real-time clock: Keypad displays current time. Refer to the CLOCK/CALENDAR section for procedures for setting the time.

Voice announcement of system status: The master keypad’s built-in speaker announces system status at

the press of a key. Refer to the

CHECKING SYSTEM STATUS

section for detailed information.

Message center: The system allows recording and play back of brief messages. Refer to the

RECORDING/PLAYBACK MESSAGES

section for procedures.

Device activation: Designated keys allow you to turn lights and/or other devices on and off. In addition, some devices (e.g., a light) may be programmed to activate automatically as a result of a system event

such as an alarm or trouble condition. Refer to the USING POWERLINE CARRIER DEVICE COMMANDS section for detailed information.

AUX key function: Designated key lets you activate a predefined series of keystrokes with a single press

of the

AUX

key plus user code, if programmed to do so (see Paging feature above). Refer to the AUX

FUNCTION section for detailed information.

Scheduling feature: Allows you to schedule the automatic activation or deactivation of X-10 devices or program events (e.g. alarm clock, reminder, and latch key).

– 3 –

Image 3
Contents 5HDG\*XDUG51 $%/2&217176 Function section for detailed information Features66702959 General InformationSecurity Codes General Operation Announced, the siren sounds Two-Way Voice FeatureOFF or until alarm bell timeout Memory of alarm displayMessage Center Volume Adjustment48,&.9,2667081&7,216 Security FunctionsTo set scheduling To remotely activate X-10 devicesTo remotely bypass a zone To remotely activate forced bypassGeneral About the Master KeypadBe repeated from its beginning Master Keypad DefinitionsKeys KEYKeys About the Display and Indicators Press Checking System StatusPress the Status Key System Can Be ArmedArming in Stay Mode Arming In Away ModeArming the System Arm Arming the System With No DelayTo arm with no Delay Quick ArmingExit Alarms Entry/Exit DelaysExit Delay Entry DelayPolice from a nearby safe location Memory of AlarmTo disarm the system and silence burglary alarms Disarming the SystemDisplaying Bypassed Zones Bypassing Protection ZonesBypassing Individual Zones Forced BypassPanic Keys / Chime Mode Chime ModePanic Keys Manual Paging Paging FeatureAutomatic Paging Code FormatTo activate X-10 devices 7 Device DescriptionsTo activate X-10 devices To deactivate X-10 devicesMessage Playback Message Recording/Playback/Volume ControlAdjusting the Volume Recording a MessagePerforming the AUX function Defining the AUX FunctionAM/PM Clock/CalendarScheduling User Interface Event Identifier Begin Time hourBegin Time am/pm End Time am/pm Begin Time minuteBegin Day End Time hourEntry Event Event Identifier EntriesEntry Day Day of Week EntriesRemote Phone Control Feature Using Remote Phone Control FeatureEnter To remotely deactivate X-10 devices To remotely arm in Stay modeTo remotely arm in Away or Stay mode with no delay To remotely disarm systemSpeaker phone will be aborted if Speaker Phone FeatureUsing the Speaker Phone Feature System will not enter speaker phone mode ifCase of Fire $/$506670If InstalledSilencing a Fire Alarm General InformationBasement $/$506670Emergency Evacuation Determine two means of escape from each room. One pathEscape quickly dont panic Add a user code 667081&7,216Security Codes To Add/Delete a User or Change a Users CodeWhen testing is completed, exit the Test mode by entering Testing the System to be conducted weeklyEntering Test Mode Exit Test ModeLOW BAT Trouble MessagesTypical Trouble Condition Displays Routine CareMaintaining your system Low Battery Conditions in Wireless SensorsChanging the ReadyGuard-REN System Battery To silence Low Battery Warning Tones at the KeypadSystem Low Battery Zones BypassedChime Event of Telephone Operational Problems Radio Frequency EmissionsTELEPHONE/MODEM Interface Notifies Insert B = Burglary, F = Fire TestingGeneral Information First Alert Professionals ReadyGuard-REN Other1st Floor Windows Owners Insurance Premium Credit RequestFurnace Room Kitchen Basement Front Door12, 38 Away ModeMaster User Rechargeable, Nickel-Metal Hydride BatteryEver Or otAre not put in proper DeathServicing Information Your security equipment or the Seller for product repair ONE Year Limited Warranty

1, K596-1 9 specifications

The First Alert K596-1 9,1 is a state-of-the-art smoke and carbon monoxide (CO) detector designed to enhance home safety. This innovative device combines advanced features and cutting-edge technology to provide reliable protection against two of the leading causes of accidental deaths in the home.

One of the standout features of the K596-1 is its **photoelectric smoke sensing technology**. This technology is particularly effective at detecting slow-smoldering fires, which typically produce larger particles of smoke. By using a light source and a sensor, the device can identify these particles quickly, thus reducing the likelihood of false alarms that are common with traditional ionization detectors.

In addition to smoke detection, the K596-1 also features a **carbon monoxide sensor**. CO is a colorless, odorless gas that can be fatal in high concentrations. The detector continuously monitors for this dangerous gas, providing peace of mind for families. If elevated levels are detected, the alarm will sound, alerting occupants to the potential danger.

The First Alert K596-1 is designed with **user-friendly features** in mind. An easy-to-read LED display provides real-time information on battery status and system functionality. The unit also includes a voice alert feature that announces the type of danger detected, whether smoke or carbon monoxide, making it easier for occupants to respond appropriately.

Battery life is another important characteristic of the K596-1. It utilizes a long-life battery that can last for several years, reducing the frequency of battery changes and ensuring that the device remains operational without constant maintenance. The easy-access battery compartment allows for a straightforward replacement when necessary.

Installation is simple, too, making the K596-1 accessible to users of all skill levels. The device can be mounted on walls or ceilings, and its compact design ensures that it blends seamlessly into any home environment.

In summary, the First Alert K596-1 9,1 is a crucial safety device that combines advanced detection capabilities with user-friendly features. Its photoelectric sensing technology and carbon monoxide detection work in tandem to provide comprehensive coverage against fire and gas hazards. With its easy installation and reliable performance, the K596-1 is a wise investment for anyone looking to enhance their home safety.