First Alert K596-1 9 manual Event Identifier Entries, Entry Event

Page 28

86(5￿)81&7,216￿

Scheduling User Interface

Event Identifier Entries

Entry

Event

 

 

Comment

 

 

0

Empty

No

event scheduled (or schedule is temporarily disabled)

 

 

 

 

 

1

X-10 Device

Turn an X-10 device, either on or off at begin/end times. (will

 

 

 

have a start and end time to program)

 

(time driven)

 

 

 

NOTE:

SH10A siren cannot be used.

 

 

 

 

 

 

 

2

Latch Key Report

Send a special pager report (7110000) indicating system not

 

 

 

 

yet disarmed. (will have a start/end time to send the report)

 

 

 

(window driven), (reports only to pager)

 

 

 

 

 

NOTE:

Option *49 must be programmed to be 6 or higher.

 

 

 

 

Make sure unit is armed prior to start of window time.

 

 

 

 

In addition a secondary phone number must be

 

 

 

 

 

programmed in Option *42.

 

 

 

 

 

 

 

 

3

Automatic Stay Arming

Will arm the system automatically, and bypass any open

 

 

 

 

 

zones, at a given time. It will send a report to the pager and

 

 

 

central station, indicating system has been auto armed stay,

 

 

 

plus all bypass reports. (will have only a start time to send the

 

 

 

report)

(time driven)

 

 

 

 

 

NOTES:

(1) Prior executing auto stay arming, force bypass

 

 

 

 

will be executed - if option *23 was enabled.

 

 

 

 

(2) If pager report is required, Option *49 must be

 

 

 

 

programmed to be 6 or higher.

 

 

 

 

 

 

 

 

4

Reminder Announcements

Will beep three times and then announce custom words 72,

 

 

 

 

 

73 and 74. This will be repeated every minute until a key is

 

 

 

depressed, or a button type zone does an arm or disarm.

 

 

 

NOTE:

Make sure installer programmed custom words 72-74

 

 

 

 

at the time of installation.

 

 

 

 

 

 

 

5

Alarm Clock

Will start a trouble tone (beep) on the speaker, which will

 

 

 

 

continue until a key is depressed.

 

 

 

 

 

 

 

 

The beeping sounds will be terminated when any key is pressed during a remote phone control session.

Figure 1.

– 28 –

Image 28
Contents 5HDG\*XDUG51 $%/2&217176 Features 66702959General Information Function section for detailed informationSecurity Codes General Operation Two-Way Voice Feature OFF or until alarm bell timeoutMemory of alarm display Announced, the siren soundsVolume Adjustment 48,&.9,2667081&7,216Security Functions Message CenterTo remotely activate X-10 devices To remotely bypass a zoneTo remotely activate forced bypass To set schedulingAbout the Master Keypad GeneralMaster Keypad Definitions Be repeated from its beginningKEY KeysKeys About the Display and Indicators Checking System Status Press the Status KeySystem Can Be Armed PressArming In Away Mode Arming in Stay ModeArming the System Arming the System With No Delay To arm with no DelayQuick Arming ArmEntry/Exit Delays Exit DelayEntry Delay Exit AlarmsMemory of Alarm To disarm the system and silence burglary alarmsDisarming the System Police from a nearby safe locationBypassing Protection Zones Bypassing Individual ZonesForced Bypass Displaying Bypassed ZonesChime Mode Panic Keys / Chime ModePanic Keys Paging Feature Automatic PagingCode Format Manual PagingDevice Descriptions To activate X-10 devicesTo deactivate X-10 devices To activate X-10 devices 7Message Recording/Playback/Volume Control Adjusting the VolumeRecording a Message Message PlaybackDefining the AUX Function Performing the AUX functionClock/Calendar AM/PMScheduling User Interface Begin Time hour Event IdentifierBegin Time am/pm Begin Time minute Begin DayEnd Time hour End Time am/pmEvent Identifier Entries Entry EventDay of Week Entries Entry DayUsing Remote Phone Control Feature Remote Phone Control FeatureEnter To remotely arm in Stay mode To remotely arm in Away or Stay mode with no delayTo remotely disarm system To remotely deactivate X-10 devicesSpeaker Phone Feature Using the Speaker Phone FeatureSystem will not enter speaker phone mode if Speaker phone will be aborted if$/$506670If Installed Silencing a Fire AlarmGeneral Information Case of Fire$/$506670 BasementDetermine two means of escape from each room. One path Emergency EvacuationEscape quickly dont panic 667081&7,216 Security CodesTo Add/Delete a User or Change a Users Code Add a user codeTesting the System to be conducted weekly Entering Test ModeExit Test Mode When testing is completed, exit the Test mode by enteringTrouble Messages Typical Trouble Condition DisplaysRoutine Care LOW BATLow Battery Conditions in Wireless Sensors Changing the ReadyGuard-REN System BatteryTo silence Low Battery Warning Tones at the Keypad Maintaining your systemZones Bypassed System Low BatteryChime Radio Frequency Emissions Event of Telephone Operational ProblemsTELEPHONE/MODEM Interface Testing General InformationFirst Alert Professionals ReadyGuard-REN Other Notifies Insert B = Burglary, F = FireOwners Insurance Premium Credit Request Furnace Room Kitchen BasementFront Door 1st Floor WindowsAway Mode 12, 38Rechargeable, Nickel-Metal Hydride Battery Master UserOr ot Are not put in properDeath EverServicing Information ONE Year Limited Warranty Your security equipment or the Seller for product repair

1, K596-1 9 specifications

The First Alert K596-1 9,1 is a state-of-the-art smoke and carbon monoxide (CO) detector designed to enhance home safety. This innovative device combines advanced features and cutting-edge technology to provide reliable protection against two of the leading causes of accidental deaths in the home.

One of the standout features of the K596-1 is its **photoelectric smoke sensing technology**. This technology is particularly effective at detecting slow-smoldering fires, which typically produce larger particles of smoke. By using a light source and a sensor, the device can identify these particles quickly, thus reducing the likelihood of false alarms that are common with traditional ionization detectors.

In addition to smoke detection, the K596-1 also features a **carbon monoxide sensor**. CO is a colorless, odorless gas that can be fatal in high concentrations. The detector continuously monitors for this dangerous gas, providing peace of mind for families. If elevated levels are detected, the alarm will sound, alerting occupants to the potential danger.

The First Alert K596-1 is designed with **user-friendly features** in mind. An easy-to-read LED display provides real-time information on battery status and system functionality. The unit also includes a voice alert feature that announces the type of danger detected, whether smoke or carbon monoxide, making it easier for occupants to respond appropriately.

Battery life is another important characteristic of the K596-1. It utilizes a long-life battery that can last for several years, reducing the frequency of battery changes and ensuring that the device remains operational without constant maintenance. The easy-access battery compartment allows for a straightforward replacement when necessary.

Installation is simple, too, making the K596-1 accessible to users of all skill levels. The device can be mounted on walls or ceilings, and its compact design ensures that it blends seamlessly into any home environment.

In summary, the First Alert K596-1 9,1 is a crucial safety device that combines advanced detection capabilities with user-friendly features. Its photoelectric sensing technology and carbon monoxide detection work in tandem to provide comprehensive coverage against fire and gas hazards. With its easy installation and reliable performance, the K596-1 is a wise investment for anyone looking to enhance their home safety.