First Alert K596-1 9 manual Zones Bypassed, System Low Battery, Chime

Page 40

6XPPDU\￿2I￿$XGLEOH￿1RWLILFDWLRQ￿

*UPPER CASE indicates announcements after pressing

STATUS

once. Lower case indicates announcements after pressing

STATUS

twice.

SOUND

 

CAUSE

 

DISPLAY

 

 

 

 

 

 

ANNOUNCEMENT*

 

INTERRUPTED

 

FIRE ALARM

 

 

FIRE ALARM

 

is displayed; zone number in

 

fire alarm + zone voice descriptor

 

Speaker and external

 

 

 

 

alarm displayed.

 

 

 

 

(Voice descriptor is interlaced

 

piezo and bell

 

 

 

 

 

 

 

 

 

 

 

with the siren and sounds every

 

 

 

 

 

 

 

 

 

 

 

 

 

 

45 seconds)

 

CONTINUOUS

 

 

BURGLARY/AUDIBLE

 

 

ALARM

is displayed; zone number in

 

alarm + zone voice descriptor

 

Speaker and external

EMERGENCY ALARM

 

 

alarm displayed.

 

 

 

 

(Voice descriptor is interlaced

 

piezo and bell

 

 

 

 

 

 

 

 

 

 

 

with the siren and sounds every

 

 

 

 

 

 

 

 

 

 

 

 

 

 

45 seconds)

 

ONE SHORT BEEP

a.

SYSTEM DISARM

 

 

a. Green LED on steady

 

 

 

a. DISARMED–READY TO ARM

 

(not repeated)

 

 

b.

SYSTEM ARMING

 

 

b. The number of the open protection zone

 

b. DISARMED–NOT READY TO

 

Speaker and external

 

ATTEMPT WITH AN OPEN

 

 

is displayed after pressing

STATUS

.

ARM

 

piezo

 

 

 

ZONE.

 

 

 

 

 

 

 

 

 

 

 

 

 

c.

BYPASS VERIFY

 

 

c. Numbers of the bypassed protection

 

c. zones bypassed

 

 

 

 

 

 

 

 

zones are displayed (One beep is heard

 

 

 

 

 

 

 

 

 

 

for each zone displayed).

 

 

 

 

ONE SHORT BEEP

a.

SYSTEM IS IN TEST MODE

 

 

a. Opened zone identifications will appear.

 

a. No announcement

 

(once every 45 secs)

b. LOW BATTERY AT A

 

 

b. LOW BAT

 

displayed with zone number

 

b. low battery + zone voice

 

Speaker and external

 

TRANSMITTER

 

 

of transmitter.

 

 

 

descriptor

 

piezo

 

 

c.

SYSTEM LOW BATTERY

 

 

c.LOW BAT

 

displayed with no zone no.

 

c. system low battery

 

 

 

 

d.

FAIL TO COMMUNICATE

 

 

d. FC displayed with no zone no.

 

 

d. check system

 

TWO SHORT BEEPS

ARM AWAY OR MAXIMUM

 

 

AWAY or AWAY + INSTANT

 

is displayed.

ARMED AWAY [INSTANT] –

 

Speaker and ext. piezo

 

 

 

 

Red ARMED indicator is lit.

 

 

EXIT NOW

 

THREE SHORT

 

 

a.

ARM STAY OR INSTANT

 

 

a. STAY

or

STAY + INSTANT

is displayed.

a. ARMED STAY [INSTANT] –

 

BEEPS

 

 

 

 

 

 

Red ARMED indicator is lit.

 

 

EXIT NOW

 

Speaker and external

b.

ZONE OPENED WHILE

 

 

b. CHIME

displayed, number of open

 

b. zone voice descriptor

 

piezo

 

 

 

SYSTEM IS IN CHIME

 

 

protection zone will be displayed if the

 

 

 

 

 

 

 

MODE.

 

 

Status key is pressed.

 

 

 

 

 

RAPID BEEPING

a. TROUBLE

 

 

a. FAULT

displayed.

Number of troubled

 

a. fault + zone voice descriptor

 

Speaker and external

 

 

 

 

protection zone is displayed.

 

 

 

 

piezo

 

 

b.

MEMORY OF ALARM

 

 

b. FIRE ALARM

or

ALARM

is displayed;

b. fire alarm or alarm + zone

 

 

 

 

 

 

 

 

zone number in alarm is displayed.

 

 

voice descriptor

 

SLOW BEEPING

 

a.

ENTRY DELAY WARNING

 

 

a. Exceeding the delay time without

 

 

a. DISARM SYSTEM NOW

 

Speaker and external

 

 

 

 

disarming causes alarm.

 

 

 

 

 

piezo

 

 

b. EXIT DELAY WARNING

 

 

b. AWAY

or

AWAY + INSTANT

 

is

b. ARMED [AWAY] [INSTANT] –

 

 

 

 

 

 

 

 

displayed

 

 

 

 

 

EXIT NOW

 

Additional Announcements:

 

 

 

 

 

 

 

 

 

 

 

 

Pressing STATUS key once will announce the following primary messages, depending on the system’s status at the time:

 

Disarmed–Ready to Arm [check system]

 

 

 

 

 

 

 

 

 

 

 

Disarmed [not ready to arm]

 

 

 

 

 

 

 

 

 

 

 

 

Armed [away] [stay] [instant] [check system] [exit now]

 

 

 

 

 

 

 

 

 

 

Pressing the STATUS key twice will announce the following secondary messages, depending on the system’s status at the time:

 

Fire Alarm + zone voice descriptor

 

Fault + zone voice descriptor

 

 

 

 

Zones Bypassed

 

Alarm + zone voice descriptor

 

Low Battery + zone voice descriptor

 

 

System Low Battery

 

Fire Fault + zone voice descriptor

 

Chime

 

 

 

 

 

 

 

AC Loss

 

 

NOTE:

If there are no secondary messages, the primary status messages will be announced.

 

 

 

 

 

 

 

LED Meanings

 

 

 

 

 

 

 

 

 

 

 

 

 

ARMED LED:

ON = System armed

 

 

 

 

 

READY LED: ON = System disarmed, ready to arm

 

(Red)

 

OFF = System disarmed

 

 

 

(Green)

 

Blinking = System disarmed, not ready to arm

 

 

 

Blinking = System armed, but a fault exists or

 

 

 

 

 

 

(a fault exists) or

once per second when AVM

 

 

 

once per second when AVM (VOX or Talk) or

 

 

 

 

 

 

(VOX

or Talk)

or speaker phone mode is

 

 

 

speaker phone mode is active.

 

 

 

 

 

 

active.

 

 

 

 

 

 

 

 

 

 

 

NOTE:

When the system is armed, the READY LED turns off.

 

– 40 –

Image 40
Contents 5HDG\*XDUG51 $%/2&217176 Features 66702959General Information Function section for detailed informationSecurity Codes General Operation Two-Way Voice Feature OFF or until alarm bell timeoutMemory of alarm display Announced, the siren soundsVolume Adjustment 48,&.9,2667081&7,216Security Functions Message CenterTo remotely activate X-10 devices To remotely bypass a zoneTo remotely activate forced bypass To set schedulingAbout the Master Keypad GeneralMaster Keypad Definitions Be repeated from its beginningKEY KeysKeys About the Display and Indicators Checking System Status Press the Status KeySystem Can Be Armed PressArming In Away Mode Arming in Stay ModeArming the System Arming the System With No Delay To arm with no DelayQuick Arming ArmEntry/Exit Delays Exit DelayEntry Delay Exit AlarmsMemory of Alarm To disarm the system and silence burglary alarmsDisarming the System Police from a nearby safe locationBypassing Protection Zones Bypassing Individual ZonesForced Bypass Displaying Bypassed ZonesChime Mode Panic Keys / Chime ModePanic Keys Paging Feature Automatic PagingCode Format Manual PagingDevice Descriptions To activate X-10 devicesTo deactivate X-10 devices To activate X-10 devices 7Message Recording/Playback/Volume Control Adjusting the VolumeRecording a Message Message PlaybackDefining the AUX Function Performing the AUX functionClock/Calendar AM/PMScheduling User Interface Begin Time hour Event IdentifierBegin Time am/pm Begin Time minute Begin DayEnd Time hour End Time am/pmEvent Identifier Entries Entry EventDay of Week Entries Entry DayUsing Remote Phone Control Feature Remote Phone Control FeatureEnter To remotely arm in Stay mode To remotely arm in Away or Stay mode with no delayTo remotely disarm system To remotely deactivate X-10 devicesSpeaker Phone Feature Using the Speaker Phone FeatureSystem will not enter speaker phone mode if Speaker phone will be aborted if$/$506670If Installed Silencing a Fire AlarmGeneral Information Case of Fire$/$506670 BasementDetermine two means of escape from each room. One path Emergency EvacuationEscape quickly dont panic 667081&7,216 Security CodesTo Add/Delete a User or Change a Users Code Add a user codeTesting the System to be conducted weekly Entering Test ModeExit Test Mode When testing is completed, exit the Test mode by enteringTrouble Messages Typical Trouble Condition DisplaysRoutine Care LOW BATLow Battery Conditions in Wireless Sensors Changing the ReadyGuard-REN System BatteryTo silence Low Battery Warning Tones at the Keypad Maintaining your systemZones Bypassed System Low BatteryChime Radio Frequency Emissions Event of Telephone Operational ProblemsTELEPHONE/MODEM Interface Testing General InformationFirst Alert Professionals ReadyGuard-REN Other Notifies Insert B = Burglary, F = FireOwners Insurance Premium Credit Request Furnace Room Kitchen BasementFront Door 1st Floor WindowsAway Mode 12, 38Rechargeable, Nickel-Metal Hydride Battery Master UserOr ot Are not put in properDeath EverServicing Information ONE Year Limited Warranty Your security equipment or the Seller for product repair

1, K596-1 9 specifications

The First Alert K596-1 9,1 is a state-of-the-art smoke and carbon monoxide (CO) detector designed to enhance home safety. This innovative device combines advanced features and cutting-edge technology to provide reliable protection against two of the leading causes of accidental deaths in the home.

One of the standout features of the K596-1 is its **photoelectric smoke sensing technology**. This technology is particularly effective at detecting slow-smoldering fires, which typically produce larger particles of smoke. By using a light source and a sensor, the device can identify these particles quickly, thus reducing the likelihood of false alarms that are common with traditional ionization detectors.

In addition to smoke detection, the K596-1 also features a **carbon monoxide sensor**. CO is a colorless, odorless gas that can be fatal in high concentrations. The detector continuously monitors for this dangerous gas, providing peace of mind for families. If elevated levels are detected, the alarm will sound, alerting occupants to the potential danger.

The First Alert K596-1 is designed with **user-friendly features** in mind. An easy-to-read LED display provides real-time information on battery status and system functionality. The unit also includes a voice alert feature that announces the type of danger detected, whether smoke or carbon monoxide, making it easier for occupants to respond appropriately.

Battery life is another important characteristic of the K596-1. It utilizes a long-life battery that can last for several years, reducing the frequency of battery changes and ensuring that the device remains operational without constant maintenance. The easy-access battery compartment allows for a straightforward replacement when necessary.

Installation is simple, too, making the K596-1 accessible to users of all skill levels. The device can be mounted on walls or ceilings, and its compact design ensures that it blends seamlessly into any home environment.

In summary, the First Alert K596-1 9,1 is a crucial safety device that combines advanced detection capabilities with user-friendly features. Its photoelectric sensing technology and carbon monoxide detection work in tandem to provide comprehensive coverage against fire and gas hazards. With its easy installation and reliable performance, the K596-1 is a wise investment for anyone looking to enhance their home safety.