NOTE: #PESBRO84 Blower may be used with Model FP-42-ZC.

Rating: 120 volts/60HZ/1.1 Amps.

See Figure 17, page 34 for wiring diagram.

NOTE: For convenience, allow licensed electrician to install properly grounded 3-plug receptacle near unit.

ROOM BLOWER INSTALLATION AND OPERATION INSTRUCTIONS

The room air blower is located at the rear of the unit in the bottom chamber. To remove or replace the blower, open lower louvered access door. The motor is located right center in rear. Remove the two (2) hex head screws holding the motor and motor bracket to the outer bottom of the unit. Unhook the two motor wires and remove the motor from the unit. Next remove the two (2) screws that fasten the motor bracket to the motor. Locate the motor bracket on the new motor in the same position as with the old. Using the two (2) hex head screws fasten the bracket to the new motor. Place new motor into the lower compartment. NOTE: Make sure the motor opening 1" x 5" is behind the inner wall of the stove and not touching any metal. Fasten the new motor and bracket to the motor support on the bottom of the unit. Hook the motor wires as shown in the diagram on page 24.

Installation and repairs should be performed by a qualified service person. The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that control compartments, burners and circulating air passageways of the appliance be kept clean.

25

Image 27
Contents Model Page Table of Contents Model Page Section I Safety Information Warnings Page Page Fireplace Preparation SectionGAS Connection Installation and ClearancesPage Millivolt only Millivolt SIT MANUAL-MODULATING GAS Pressure CheckWhat to do if YOU Smell GAS Rocker Switch ITT Valve Shutting OFF Unit To Turn OFF GAS to ApplianceThermostat Control Operation Manual Lighting ProcedureLighting Instruction Modulating Valve SIT Manual Valve SIT For Your Safety Read Before LightingLighting Instruction Page Thermostat Control Operation Operating Instructions Page Page Manual Lighting Procedure B. LOG SET When Used AS a Heating Appliance Heat OutputFlame Check CR3329 LOG SETWiring Diagram Room Blower Installation and Operation Instructions Ceiling Page Page Page Drafts Section V Model 34 ZC Zero Clearance InstallationChoosing the Location for Your Fireplace GAS LineGAS Line Fireplace Clearances ZC Installing the Firebox ZCClearances ZC Finishing Your Fireplace ZCSection After Market Mobile Home Installation Producing Adequate Ventilation Determining FRESH-AIR Flow for Heater LocationDetermine if YOU have a Confined or Unconfined Space Determine the volume of the space length x width x height Ventilation AIR from Inside Building Ventilation AIRVentilation AIR from Outdoors Cleaning Important SafeguardsSolution Observed Possible Problem CauseObserved Possible Problem Solution Observed Possible Problem Cause Solution Observed Possible Problem Cause Solution Servicing Repair PartsReplacement Parts OFF PO 385BINIP PE RV20LF90PE RV20LF35 PO 382BINIPTSi Orifice PO Orifice Orifice Holder PO 54ORFHLD NUT & Sleeve Replacement PartsS Pilot NAT. O.P. Assembly MF 31621ALMTUBSIT Millivolt Replacement Parts for Ember Stove Base ESB ESB Warranty does not Cover Limited Warranty VENT-FREE GAS LOG Heater