| OBSERVED | POSSIBLE |
|
|
|
| |
|
| PROBLEM | CAUSE | SOLUTION | ||||
|
| Burner does not light after ODS/ | 1. | Burner orifice is clogged | 1. | Clean burner (see Cleaning | ||
|
| Pilot is lit |
|
|
| and Maintenance) or replace | ||
|
|
|
|
|
| burner orifice | ||
|
|
| 2. | Inlet gas pressure is too low | 2. | Contact local propane gas | ||
|
|
|
|
|
| company | ||
|
|
|
|
|
|
|
|
|
|
| Delayed ignition of burner | 1. | Manifold pressure is too low | 1. | Contact local propane gas | ||
|
|
|
|
|
| company | ||
|
|
| 2. | Burner orifice is clogged | 2. | Clean burner (see Cleaning | ||
|
|
|
|
|
| and Maintenance) or replace | ||
|
|
|
|
|
| burner orifice | ||
|
|
|
|
|
|
|
| |
|
| Burner backfiring during | 1. | Burner orifice is clogged or | 1. | Clean burner (see Cleaning | ||
|
| combustion |
| damaged |
| and Maintenance) or replace | ||
|
|
|
|
|
| burner orifice | ||
|
|
| 2. | Burner damaged | 2. | Replace burner | ||
|
|
| 3. | Gas regulator defective | 3. | Replace gas regulator | ||
|
| Slight smoke or odor during | 1. | Residues from manufacturing | 1. | Problem will stop after a few | ||
|
| initial operation |
| process |
| hours of operation | ||
|
| Heater produces a whistling | 1. | Turning control knob to “HI” | 1. | Turn control knob to “LOW” | ||
|
| noise when burner is lit |
| position when burner is cold |
| position and allow to warm | ||
|
|
|
| (if equipped with this type of |
|
|
|
|
|
|
|
| valve) |
|
|
|
|
|
|
| 2. | Air in gas line | 2. | Operate burner until air is | ||
|
|
|
|
|
| removed from line. Call | ||
|
|
|
|
|
| local propane company to | ||
|
|
|
|
|
| check gas line. | ||
|
|
| 3. | Air passageways on heater | 3. | Observe minimum | ||
|
|
|
| blocked |
| installation clearances | ||
|
|
| 4. | Dirty or partially clogged | 4. | Clean burner or replace | ||
|
|
|
| burner orifice |
| orifice |
42