Page 32

SECTION V MODEL 34 (ZC) ZERO CLEARANCE INSTALLATION

The installation must conform with local codes ,or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA54.

This appliance may be installed in an After-Market*Manufactured (Mobile) Home, where not prohibited by state or local codes.

* (After Market: Completion of sale, not for the purpose of resale from the manufacturer).

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

NOTE: See “Producing Adequate Ventilation” page 35.

CHOOSING THE LOCATION FOR YOUR FIREPLACE:

The figure below shows some of the many ways your fireplace may be installed. Consider the traffic pattern in your room and the location of doors and windows. Moving air from ceiling fans, open doors, and hot air grills may cause the flames to soot. If a disturbance is found that affects the flames, it must be eliminated by turning off the ceiling fan, closing the door, or closing or moving the hot air register. A corner location may be best where space is limited.

Your fireplace weighs no more than some of your fine furniture. If the fireplace is located near a load bearing wall, additional supports to the foundation will not be necessary. HEAVY FACINGS, SUCH AS BRICK, STONE, ETC., MAY REQUIRE ADDITIONAL FOUNDATION SUPPORT.

NOTE: If this appliance is installed directly on carpeting, tile or other combustible material, other than wood flooring, the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance.

GAS LINE

The gas supply line and electrical supply must be installed before framing in the fireplace by a licensed installer.

DRAFTS

Do not locate the fireplace in high traffic areas or areas exposed to high drafts and winds. Locate the fireplace away from furniture and draperies.

PARTIAL ROOM PROJECTION

ROOM DIVIDER

 

FULL ROOM PROJECTION

CORNER

FLUSH

30

Image 32
Contents Model Page Table of Contents Model Page Section I Safety Information Warnings Page Page Section Fireplace PreparationInstallation and Clearances GAS ConnectionPage Millivolt only GAS Pressure Check Millivolt SIT MANUAL-MODULATINGWhat to do if YOU Smell GAS Rocker Switch ITT Valve To Turn OFF GAS to Appliance Shutting OFF UnitManual Lighting Procedure Thermostat Control OperationFor Your Safety Read Before Lighting Lighting Instruction Modulating Valve SIT Manual Valve SITLighting Instruction Page Thermostat Control Operation Operating Instructions Page Page Manual Lighting Procedure When Used AS a Heating Appliance Heat Output Flame CheckCR3329 LOG SET B. LOG SETWiring Diagram Room Blower Installation and Operation Instructions Ceiling Page Page Page Section V Model 34 ZC Zero Clearance Installation Choosing the Location for Your FireplaceGAS Line DraftsGAS Line Installing the Firebox ZC Fireplace Clearances ZCFinishing Your Fireplace ZC Clearances ZCSection After Market Mobile Home Installation Determine if YOU have a Confined or Unconfined Space Producing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Determine the volume of the space length x width x height Ventilation AIR Ventilation AIR from Inside BuildingVentilation AIR from Outdoors Important Safeguards CleaningObserved Possible Problem Cause SolutionObserved Possible Problem Solution Observed Possible Problem Cause Solution Observed Possible Problem Cause Solution Repair Parts ServicingReplacement Parts OFF PE RV20LF90 PE RV20LF35PO 382BINIP PO 385BINIPTSi Replacement Parts S Pilot NAT. O.P. AssemblyMF 31621ALMTUB Orifice PO Orifice Orifice Holder PO 54ORFHLD NUT & SleeveSIT Millivolt Replacement Parts for Ember Stove Base ESB ESB Limited Warranty VENT-FREE GAS LOG Heater Warranty does not Cover