New Buck Corporation 34 manual Replacement Parts, S Pilot NAT. O.P. Assembly, MF 31621ALMTUB

Page 51

REPLACEMENT PARTS

 

SIT MILLIVOLT VALVE

 

 

Picture on Page 50

 

KEY#

PART DESCRIPTION

PART NUMBER

1.

820 MV. S.I.T. VALVE

LP-PE 820636

 

 

NAT– PE 820637

2.

GENERATOR

(PILOT ASSEMBLY)

3.

BURNER TUBE

PO DTBURN

4.

O.D.S PILOT (L.P.) O.P. ASSEMBLY

PE 8404C

 

O.D.S PILOT (NAT.) O.P. ASSEMBLY

PE 8204C

5.

THERMO-COUPLE

(PILOT ASSEMBLY)

6.

2"-3/8" BLACKIRON NIPPLE

PO 382BINIP

7.

BURNER SUPPLY LINE ELBOW

PH4966

8.

21" PILOT TUBE 3/16"

MF 31621ALMTUB

9.

ORIFICE

PO ORIFICE

10.

ORIFICE HOLDER

PO 54ORFHLD

11.

3/8" NUT & SLEEVE

PH 616 & PH 606

12.

PIEZO STRIKER

PE 124461

13.CARLING SWITCH

 

(AUTO/OFF/MANUAL)

PE RC211RB

14.

12" SWITCH WIRES

PE 12 JUMPER

15.

12" GENERATOR WIRE

(PILOT ASSEMBLY)

16.

14 3/4" x 3/8" BURNER SUPPLY TUBE

PO 381434ALMTUB

17.

3/8" FIP TO 1/2" MPT PIPE BUSHING

PH 11086

18.

1/2" BALL VALVE WITH PRESSURE TAP

PO 110-553

19.

1/2" FLARE TO 1/2" STRAIGHT

(FLEX LINE ASSEMBLY)

20.

1/2" FLEX LINE

PO 20-213-12

21.

1/2" FLARE TO 3/8" FLARE

PH 4286

 

OTHER PARTS (NOT SHOWN)

22.

Blower Motor

PE SBR084

23.

Power Cord

PE 400240

24.

Strain Release

PE 400320

25.

Thermostat

PE 400130

26.

Male Terminals

PE 5X428

27.

Jumper Wire 12"

PE 12JUMPER

28.

Gas Log Set

PO CR34LOG

29.

Fan Speed Control Label

PE KB9724

30.

Rheostat

PE BC204

31.

Rheostat Knob

PE BC204A

32.

Heyco 1-1/4" Grommet

PO HEYCO 2883

49

Image 51
Contents Model Page Table of Contents Model Page Section I Safety Information Warnings Page Page Fireplace Preparation SectionGAS Connection Installation and ClearancesPage Millivolt only Millivolt SIT MANUAL-MODULATING GAS Pressure CheckWhat to do if YOU Smell GAS Rocker Switch ITT Valve Shutting OFF Unit To Turn OFF GAS to ApplianceThermostat Control Operation Manual Lighting ProcedureLighting Instruction Modulating Valve SIT Manual Valve SIT For Your Safety Read Before LightingLighting Instruction Page Thermostat Control Operation Operating Instructions Page Page Manual Lighting Procedure B. LOG SET When Used AS a Heating Appliance Heat OutputFlame Check CR3329 LOG SETWiring Diagram Room Blower Installation and Operation Instructions Ceiling Page Page Page Drafts Section V Model 34 ZC Zero Clearance InstallationChoosing the Location for Your Fireplace GAS LineGAS Line Fireplace Clearances ZC Installing the Firebox ZCClearances ZC Finishing Your Fireplace ZCSection After Market Mobile Home Installation Producing Adequate Ventilation Determining FRESH-AIR Flow for Heater LocationDetermine if YOU have a Confined or Unconfined Space Determine the volume of the space length x width x height Ventilation AIR from Inside Building Ventilation AIRVentilation AIR from Outdoors Cleaning Important SafeguardsSolution Observed Possible Problem CauseObserved Possible Problem Solution Observed Possible Problem Cause Solution Observed Possible Problem Cause Solution Servicing Repair PartsReplacement Parts OFF PO 385BINIP PE RV20LF90PE RV20LF35 PO 382BINIPTSi Orifice PO Orifice Orifice Holder PO 54ORFHLD NUT & Sleeve Replacement PartsS Pilot NAT. O.P. Assembly MF 31621ALMTUBSIT Millivolt Replacement Parts for Ember Stove Base ESB ESB Warranty does not Cover Limited Warranty VENT-FREE GAS LOG Heater