WIRING DIAGRAM

MOTOR

JUMPERTHERMOSTAT

JUMPER

GREEN

JUMPER

WHITE

BLACK

RHEOSTAT

POWER CORD

BLACK

Figure 5

NOTE: “If any of the original wire as supplied with the gas appliance must be replaced, it must be replaced with a wire of at least a 105o C. temperature rating.”

NOTE: Installation and repair should be done by a qualified service person. This heater should be inspected before use and at least annually by a qualified service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that control compartments and circulating air passageways of the heater be kept clean.

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.

Verify proper operation after servicing.

24

Image 26
Contents Model Page Table of Contents Model Page Section I Safety Information Warnings Page Page Section Fireplace PreparationInstallation and Clearances GAS ConnectionPage Millivolt only GAS Pressure Check Millivolt SIT MANUAL-MODULATINGWhat to do if YOU Smell GAS Rocker Switch ITT Valve To Turn OFF GAS to Appliance Shutting OFF UnitManual Lighting Procedure Thermostat Control OperationFor Your Safety Read Before Lighting Lighting Instruction Modulating Valve SIT Manual Valve SITLighting Instruction Page Thermostat Control Operation Operating Instructions Page Page Manual Lighting Procedure CR3329 LOG SET When Used AS a Heating Appliance Heat OutputFlame Check B. LOG SETWiring Diagram Room Blower Installation and Operation Instructions Ceiling Page Page Page GAS Line Section V Model 34 ZC Zero Clearance InstallationChoosing the Location for Your Fireplace DraftsGAS Line Installing the Firebox ZC Fireplace Clearances ZCFinishing Your Fireplace ZC Clearances ZCSection After Market Mobile Home Installation Determine if YOU have a Confined or Unconfined Space Producing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Determine the volume of the space length x width x height Ventilation AIR Ventilation AIR from Inside BuildingVentilation AIR from Outdoors Important Safeguards CleaningObserved Possible Problem Cause SolutionObserved Possible Problem Solution Observed Possible Problem Cause Solution Observed Possible Problem Cause Solution Repair Parts ServicingReplacement Parts OFF PO 382BINIP PE RV20LF90PE RV20LF35 PO 385BINIPTSi MF 31621ALMTUB Replacement PartsS Pilot NAT. O.P. Assembly Orifice PO Orifice Orifice Holder PO 54ORFHLD NUT & SleeveSIT Millivolt Replacement Parts for Ember Stove Base ESB ESB Limited Warranty VENT-FREE GAS LOG Heater Warranty does not Cover