New Buck Corporation 34 manual Replacement Parts for Ember Stove Base ESB

Page 53

REPLACEMENT PARTS FOR

EMBER STOVE BASE (ESB)

(PICTURE ON PAGE 47)

A parts list with exploded view follows. Always include correct name, part number, and model number of the heater when ordering service parts.

KEY#

PART DESCRIPTION

 

SIT - MILLIVOLT

1.O.D.S. PILOT (L.P.) O.P. ASSEMBLY

1.O.D.S. PILOT (NAT) O.P. ASSEMBLY

2.GENERATOR ASSEMBLY

3.PILOT TUBE 3/16"

4.GENERATOR WIRE

5.REAR BURNER FRONT BURNER

6.INLET ELBOW

7.3/8" COMP. NUT & SLEEVE

8.3/8" BURNER SUPPLY TUBE (FLEX)

-3 pieces 12"

9.24" SWITCH WIRES

10.CARLING SWITCH (AUTO/OFF/MANUAL)

11.PIEZO STRIKER

12.PIEZO 18" IGNITOR WIRE

13.MALE RUN TEE FITTING

14.THERMO-COUPLE

15.MANIFOLD OUTLET CONNECTOR

16.ORIFICES L.P.

FRONT #1.25mm

REAR #.046”

NATURAL

FRONT #2.05mm

REAR #48

17.820 mv. S.I.T. VALVE

18.8”L 3/8”BURNER SUPPLY LINE

(3/4”-3/8” FLARE/3/8” COMP. N&S FITTINGS)

PART NUMBER

PE 8404C

PE 8204C

(Part of Pilot Assembly) MF 31612 ALMTUB (Part of Pilot Assembly) PO VE1002

PO 383436

PH 4966

PH 616 & PH 606

PO T6-12

PE 30JUMPER

PE RC211RB

PE 124461

PE 8400-014

PH 64A-66

PH 68A-6C

PO 125 MVORF

PO 046 MVORF

PO 205 MVORF

PO 48 MVORF

LP - PE 820-636

NAT - PE 820-637

MF382ALMTUB

*

LOG SET

EMBER STOVE BASE (CERAMIC)

51

Image 53
Contents Model Page Table of Contents Model Page Section I Safety Information Warnings Page Page Fireplace Preparation SectionGAS Connection Installation and ClearancesPage Millivolt only Millivolt SIT MANUAL-MODULATING GAS Pressure CheckWhat to do if YOU Smell GAS Rocker Switch ITT Valve Shutting OFF Unit To Turn OFF GAS to ApplianceThermostat Control Operation Manual Lighting ProcedureLighting Instruction Modulating Valve SIT Manual Valve SIT For Your Safety Read Before LightingLighting Instruction Page Thermostat Control Operation Operating Instructions Page Page Manual Lighting Procedure Flame Check When Used AS a Heating Appliance Heat OutputCR3329 LOG SET B. LOG SETWiring Diagram Room Blower Installation and Operation Instructions Ceiling Page Page Page Choosing the Location for Your Fireplace Section V Model 34 ZC Zero Clearance InstallationGAS Line DraftsGAS Line Fireplace Clearances ZC Installing the Firebox ZCClearances ZC Finishing Your Fireplace ZCSection After Market Mobile Home Installation Determine if YOU have a Confined or Unconfined Space Producing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Determine the volume of the space length x width x height Ventilation AIR from Inside Building Ventilation AIRVentilation AIR from Outdoors Cleaning Important SafeguardsSolution Observed Possible Problem CauseObserved Possible Problem Solution Observed Possible Problem Cause Solution Observed Possible Problem Cause Solution Servicing Repair PartsReplacement Parts OFF PE RV20LF35 PE RV20LF90PO 382BINIP PO 385BINIPTSi S Pilot NAT. O.P. Assembly Replacement PartsMF 31621ALMTUB Orifice PO Orifice Orifice Holder PO 54ORFHLD NUT & SleeveSIT Millivolt Replacement Parts for Ember Stove Base ESB ESB Warranty does not Cover Limited Warranty VENT-FREE GAS LOG Heater