OBSERVED

 

 

 

 

POSSIBLE

PROBLEM

CAUSE

 

 

 

 

 

 

Igniter button is pressed

1.

Igniter electrode positioned

No spark at ODS/Pilot

 

incorrectly

 

 

2.

Igniter electrode broken

 

 

3.

Igniter electrode not

 

 

 

connected to igniter cable

 

 

4.

Igniter cable pinched or wet

 

 

5.

Piezo igniter nut is loose

 

 

6.

Broken igniter cable

 

 

7.

Bad piezo igniter

OBSERVED

POSSIBLE

PROBLEM

CAUSE

 

 

 

 

Igniter button is pressed

1.

Gas supply turned off or

Spark at ODS/Pilot

 

manual shutoff valve is

No Ignition

 

closed

 

 

2.

Control knob not in “PILOT”

 

 

 

position

 

 

3.

Control knob not pressed in

 

 

 

while in “PILOT” position

 

 

 

 

 

 

 

 

 

 

 

 

SOLUTION

1.Replace igniter

2.Replace igniter

3.Reconnect igniter cable

4.Free igniter cable if pinched by any metal or tubing. Keep igniter cable dry.

5.Tighten nut holding piezo igniter to heater cabinet. Nut is located inside heater cabinet at top.

6.Replace igniter cable

7.Replace piezo igniter

SOLUTION

1.Turn on gas supply or open manual shutoff valve

2.Turn control knob to “PILOT” position

3.Press in control knob while in “PILOT” position

40

Image 42
Contents Model Page Table of Contents Model Page Section I Safety Information Warnings Page Page Section Fireplace PreparationInstallation and Clearances GAS ConnectionPage Millivolt only GAS Pressure Check Millivolt SIT MANUAL-MODULATINGWhat to do if YOU Smell GAS Rocker Switch ITT Valve To Turn OFF GAS to Appliance Shutting OFF UnitManual Lighting Procedure Thermostat Control OperationFor Your Safety Read Before Lighting Lighting Instruction Modulating Valve SIT Manual Valve SITLighting Instruction Page Thermostat Control Operation Operating Instructions Page Page Manual Lighting Procedure CR3329 LOG SET When Used AS a Heating Appliance Heat OutputFlame Check B. LOG SETWiring Diagram Room Blower Installation and Operation Instructions Ceiling Page Page Page GAS Line Section V Model 34 ZC Zero Clearance InstallationChoosing the Location for Your Fireplace DraftsGAS Line Installing the Firebox ZC Fireplace Clearances ZCFinishing Your Fireplace ZC Clearances ZCSection After Market Mobile Home Installation Producing Adequate Ventilation Determining FRESH-AIR Flow for Heater LocationDetermine if YOU have a Confined or Unconfined Space Determine the volume of the space length x width x height Ventilation AIR Ventilation AIR from Inside BuildingVentilation AIR from Outdoors Important Safeguards CleaningObserved Possible Problem Cause SolutionObserved Possible Problem Solution Observed Possible Problem Cause Solution Observed Possible Problem Cause Solution Repair Parts ServicingReplacement Parts OFF PO 382BINIP PE RV20LF90PE RV20LF35 PO 385BINIPTSi MF 31621ALMTUB Replacement PartsS Pilot NAT. O.P. Assembly Orifice PO Orifice Orifice Holder PO 54ORFHLD NUT & SleeveSIT Millivolt Replacement Parts for Ember Stove Base ESB ESB Limited Warranty VENT-FREE GAS LOG Heater Warranty does not Cover