Quick Start (cont’d)

Action Menu 4

?

Enter choice:

SysInfo

ID codes

 

 

 

 

Name pnt/gps

Load

 

 

 

 

 

 

 

 

Previous

First

Action Menu 4 contains four feature selections:

SysInfo – Displays model number, revision, and date of your FOCUS 200 PLUS system.

Name pnt/gps – Displays or changes the name, number, and type of each protection point or group.

ID codes – Changes user names, group access, privileges, card/key number, cancel dates, and/or adds/changes the ID code of the first 255 users.

Load – Downloads changes into the system from a remote ADT Service Terminal.

EXERCISE: NAME PNT/GPS

This exercise uses both the menu screens and the numeric keypad. Enter your ID code and scroll to Action Menu 4 using the More key. Choose Name pnt/gps to display the first BA group description. The FOCUS 200 PLUS lists groups first, then card/key readers, then points. If you are familiar with your protection point ID numbers, you may go directly to a point by entering its corresponding three-digit number on the keypad.

Pressing Change now displays the selector keys for entering a new description for a point or group from the Character Entry Screen.

23

Image 23
Contents Security System Table of Contents Introduction FOCUS 200 Plus FeaturesSystem Overview Operating Panel System Overview cont’dControl Unit Protection Points and Groups User Access and SecuritySummary Automated Event Recording and PrintingFalse Alarm Prevention You must help eliminate false alarms False Alarm Prevention cont’dPreventing causes of false alarms False Alarm Prevention cont’d Operating Panel Functions Quick StartOffMore Enter ID Quick Start cont’dNormal Inactive Screen Front OfficeViewing Current Alarms Responding to AlarmsEntering Your Personal ID Number More/First Selection Navigational Menu SelectionsHostage Other Navigational Selections Quit/Previous SelectionAre on Code Accepted Continue Turn Off Turning BA Groups OffSummary Navigational Selections Some BA GroupsEnter choice Action Menus 1-4 Main FeaturesSee alarms Reset Quit More Assistance The ? Selection Action MenuExercise the ? Selection Exercise Turn on Burglary Protection See points Test Change close time Previous MoreExercise Test Bypass History Status Time Previous MoreExercise BYPASS/UNBYPASS Protection Points Bypass points See limits QuitExercise Name PNT/GPS SysInfo ID codes Name pnt/gps Load Previous FirstBack CHR Forward Left POS Right Quit ? First BA GroupSummary Operating Panel System Operation OverviewSystem Operation Overview cont’d Action Menus See alarms Reset Quit MoreSee points Test Change close time Previous More Bypass History StatusTime Previous More SysInfo ID codes Name pnt/gps Load Previous First User Data System ProgrammingEntering or Changing a User Name System Programming cont’dUser Delete PrevChange Quit Next User Selection MenuUser Name Deleting a User ID Code Assigning or Changing User Access Assigning Privilege Levels Assigning Burglary Group AccessSystem Programming cont’d Access Capability Assigning a User a Card/Key Code Assigning a Code and Card Cancel DateAssigning a User ID Code ? Time Changing the Time and DateTime Selection Menu Changing the Current TimeChanging the Current Date Setting Dates for Daylight Saving TimeDaily Operating Schedules Changing Daily Operating Schedules Hint The system will start display with today Mon-Sun Guidelines for Changing Daily Operating SchedulesGuidelines Changing Auto On/Off ScheduleSystem Programming cont’d ? Time Holiday Daylight Open/close Hstg Quit Current Changing Open/Close Schedule LimitsAdding or Changing Holiday Descriptions Holiday Description and DatesSystem Programming cont’d Changing Holiday Dates Group/Point DescriptionsSystem Programming cont’d Turning On ALL Burglary Groups System OperationTurning On Burglary Protection Turning On One or More Burglary Groups Lesson Turn on See alarms Reset Quit MoreSystem Operation cont’d Turning Off Burglary Protection Continue Turn Off Turn Off MenuTurning Off ALL Burglary Groups Are onResetting Current Alarms Viewing the History Log System History LogTriggering a Panic Printing the History Log History Selection MenuOn this screen On printer Quit Description Alpha System Event History Log Alpha and Event CodesDescription Alpha Expansion Module Description Alpha Description Alpha Panic Description Alpha Other Access Bypassing/Unbypassing Burglary Protection Group Description PreviousNext Quit Bypass Selection MenuGroup Selection Menu Bypassing Protection PointsBypassing/Unbypassing Vault Vibration Sensors VVS Quit Bypass VVSUnbypassing Protection Points Extending Close Time Sending Messages to a Pager Burglary Protection Points Audible System TestProtection Points Visual System Test cont’dProtection Groups Testing Holdup, Fire, and Supervisory DevicesBell and Operating Panel Display Trouble or Error Display Description Action Troubleshooting GuideTime to turn on ‘Group Description’ or extend closing time Troubleshooting Guide cont’dFire, SPV or Holdup points bypassed Code Enforcement Fire Alarm Application NoteAbout Fire Alarm Codes ADT’s Focus 200 Plus Fire Alarm System CapabilitiesEmergency Evacuation Federal Communications Commission FCC Part 15 Statement Notification Federal Communications Commission FCC Part 68 Notice Canadian Department of Communications DOC Statement Limitations of this Alarm System Limitations of this Alarm System Index ADT Service personnel working on system76Limitations of this Alarm System ÊK3693-1SIA†Š