ADT Security Services 200 Plus manual Protection Points and Groups, User Access and Security

Page 5

System Overview (cont’d)

Protection Points and Groups

The FOCUS 200 PLUS monitors up to 255 protection points in up to eight independent fire and burglary groups. The system lets you designate group names in ways that make sense for your specific needs. For example, “Office” and “Warehouse” could cover two sets of entry doors that activate/deactivate independently.

Turning groups on and off allows different tasks to be carried out at different times of day, all while maintaining the optimal level of safety and security.

By scrolling through the FOCUS 200 PLUS menu options, you may turn groups on/off in the AWAY or STAY mode, or bypass points at any time for maintenance or servicing. The system also allows you to check points or groups to review their status, and alerts you to the precise location of an activated alarm. Although some features may be manually activated or deactivated at any time, FOCUS 200 PLUS also features powerful scheduling capabilities for automated, worry-free operation.

The combination of point/group control and scheduling features allows operators of the system to construct versatile scenarios quickly and with no previous programming knowledge.

NOTE: Keypads assigned to group 1 will duplicate all entry, exit, and alarm sounds generated by the keypads assigned to other groups.

User Access and Security

Each FOCUS 200 PLUS card/key reader acts as a security gateway to your workplace, or to a specific area where certain employees have access and others do not. This feature, which operates on manual-input codes, Wiegand, proximity, magnetic cards, or Marlok keys, allows tracking of all security- related activities, either through a continuous printout or by accessing the 1000-event history log. The FOCUS 200 PLUS supports up to 999 different users (maximum 255 user codes, the rest are access cards only) and various levels of security with all the flexibility you will need to assure that every employee has the proper level of access to the workplace areas.

– 5 –

Image 5
Contents Security System Table of Contents Introduction FOCUS 200 Plus FeaturesSystem Overview Operating Panel System Overview cont’dControl Unit Protection Points and Groups User Access and SecuritySummary Automated Event Recording and PrintingFalse Alarm Prevention You must help eliminate false alarms False Alarm Prevention cont’dPreventing causes of false alarms False Alarm Prevention cont’d Operating Panel Functions Quick StartNormal Inactive Screen Quick Start cont’dFront Office OffMore Enter IDViewing Current Alarms Responding to AlarmsEntering Your Personal ID Number More/First Selection Navigational Menu SelectionsHostage Other Navigational Selections Quit/Previous SelectionSummary Navigational Selections Turning BA Groups OffSome BA Groups Are on Code Accepted Continue Turn OffSee alarms Reset Quit More Assistance The ? Selection Action Menus 1-4 Main FeaturesAction Menu Enter choiceExercise the ? Selection Exercise Turn on Burglary Protection See points Test Change close time Previous MoreExercise Test Bypass History Status Time Previous MoreExercise BYPASS/UNBYPASS Protection Points Bypass points See limits QuitExercise Name PNT/GPS SysInfo ID codes Name pnt/gps Load Previous FirstBack CHR Forward Left POS Right Quit ? First BA GroupSummary Operating Panel System Operation OverviewSystem Operation Overview cont’d Action Menus See alarms Reset Quit MoreSee points Test Change close time Previous More Bypass History StatusTime Previous More SysInfo ID codes Name pnt/gps Load Previous First User Data System ProgrammingEntering or Changing a User Name System Programming cont’dUser Delete PrevChange Quit Next User Selection MenuUser Name Deleting a User ID Code Assigning or Changing User Access Assigning Privilege Levels Assigning Burglary Group AccessSystem Programming cont’d Access Capability Assigning a User a Card/Key Code Assigning a Code and Card Cancel DateAssigning a User ID Code Time Selection Menu Changing the Time and DateChanging the Current Time ? TimeChanging the Current Date Setting Dates for Daylight Saving TimeDaily Operating Schedules Changing Daily Operating Schedules Hint The system will start display with today Mon-Sun Guidelines for Changing Daily Operating SchedulesGuidelines Changing Auto On/Off ScheduleSystem Programming cont’d ? Time Holiday Daylight Open/close Hstg Quit Current Changing Open/Close Schedule LimitsAdding or Changing Holiday Descriptions Holiday Description and DatesSystem Programming cont’d Changing Holiday Dates Group/Point DescriptionsSystem Programming cont’d Turning On ALL Burglary Groups System OperationTurning On Burglary Protection Turning On One or More Burglary Groups Lesson Turn on See alarms Reset Quit MoreSystem Operation cont’d Turning Off Burglary Protection Turning Off ALL Burglary Groups Turn Off MenuAre on Continue Turn OffResetting Current Alarms Viewing the History Log System History LogTriggering a Panic Printing the History Log History Selection MenuOn this screen On printer Quit Description Alpha System Event History Log Alpha and Event CodesDescription Alpha Expansion Module Description Alpha Description Alpha Panic Description Alpha Other Access Bypassing/Unbypassing Burglary Protection Group Selection Menu Bypass Selection MenuBypassing Protection Points Group Description PreviousNext QuitBypassing/Unbypassing Vault Vibration Sensors VVS Quit Bypass VVSUnbypassing Protection Points Extending Close Time Sending Messages to a Pager Burglary Protection Points Audible System TestProtection Points Visual System Test cont’dProtection Groups Testing Holdup, Fire, and Supervisory DevicesBell and Operating Panel Display Trouble or Error Display Description Action Troubleshooting GuideTime to turn on ‘Group Description’ or extend closing time Troubleshooting Guide cont’dFire, SPV or Holdup points bypassed About Fire Alarm Codes Fire Alarm Application NoteADT’s Focus 200 Plus Fire Alarm System Capabilities Code EnforcementEmergency Evacuation Federal Communications Commission FCC Part 15 Statement Notification Federal Communications Commission FCC Part 68 Notice Canadian Department of Communications DOC Statement Limitations of this Alarm System Limitations of this Alarm System Index ADT Service personnel working on system76Limitations of this Alarm System ÊK3693-1SIA†Š