ADT Security Services 200 Plus manual Entering Your Personal ID Number

Page 14

Quick Start (cont’d)

To view current alarms, perform the following steps:

1Using the operating panel’s numeric keypad, enter a valid ID code to display the Action Menu 1 (see page 19) if no burglary groups are on; or press the “Turn off” selector button (if burglary groups are on) to deactivate all annunciating devices.

2If any burglary groups are on, complete the steps under “Turning Off Burglary Protection” in the SYSTEM OPERATION section. When all burglary groups are off, press Continue to display Action Menu 1.

3Press See alarms to display the alarm type, point number, and description.

4Press Prev or Next to display additional alarms.

5Press Quit to display Action Menu 1.

Entering Your Personal ID Number

The first step in performing any function within the FOCUS 200 PLUS system is to enter your personal six-digit ID number.

To enter a valid ID code, perform the following steps:

1Enter your six-digit personal ID number. You should hear a short beep after each digit is entered. After your number has been accepted, you will hear a longer beep.

2Now wait about 15 seconds and try to enter another, random six-digit number. What happens now?

The number is recognized as an invalid ID code and the operating panel will display “Code Incorrect, Try Again.”

3If you make a mistake, press “Clear” to re-enter the number.

The operating panel is active for 10 seconds after a valid code is entered. You must enter a menu selection within that time or the operating panel will deactivate, requiring the input of a valid ID code again. Once you have selected a menu item, however, the panel remains active for a full minute before becoming inactive. This timeout feature automatically secures your FOCUS 200 PLUS security system in the event of a distraction or emergency that causes you to step away from the operating panel.

14 –

Image 14
Contents Security System Table of Contents Introduction FOCUS 200 Plus FeaturesSystem Overview Operating Panel System Overview cont’dControl Unit User Access and Security Protection Points and GroupsAutomated Event Recording and Printing SummaryFalse Alarm Prevention False Alarm Prevention cont’d You must help eliminate false alarmsPreventing causes of false alarms False Alarm Prevention cont’d Quick Start Operating Panel FunctionsFront Office Quick Start cont’dNormal Inactive Screen OffMore Enter IDResponding to Alarms Viewing Current AlarmsEntering Your Personal ID Number More/First Selection Navigational Menu SelectionsHostage Quit/Previous Selection Other Navigational SelectionsSome BA Groups Turning BA Groups OffSummary Navigational Selections Are on Code Accepted Continue Turn OffAction Menu Action Menus 1-4 Main FeaturesSee alarms Reset Quit More Assistance The ? Selection Enter choiceExercise the ? Selection See points Test Change close time Previous More Exercise Turn on Burglary ProtectionBypass History Status Time Previous More Exercise TestBypass points See limits Quit Exercise BYPASS/UNBYPASS Protection PointsSysInfo ID codes Name pnt/gps Load Previous First Exercise Name PNT/GPS? First BA Group Back CHR Forward Left POS Right QuitSummary System Operation Overview Operating PanelSystem Operation Overview cont’d See alarms Reset Quit More Action MenusSee points Test Change close time Previous More Bypass History StatusTime Previous More SysInfo ID codes Name pnt/gps Load Previous First System Programming User DataSystem Programming cont’d Entering or Changing a User NameUser Delete PrevChange Quit Next User Selection MenuUser Name Deleting a User ID Code Assigning or Changing User Access Assigning Burglary Group Access Assigning Privilege LevelsSystem Programming cont’d Access Capability Assigning a User a Card/Key Code Assigning a Code and Card Cancel DateAssigning a User ID Code Changing the Current Time Changing the Time and DateTime Selection Menu ? TimeSetting Dates for Daylight Saving Time Changing the Current DateDaily Operating Schedules Changing Daily Operating Schedules Guidelines for Changing Daily Operating Schedules Hint The system will start display with today Mon-SunChanging Auto On/Off Schedule GuidelinesSystem Programming cont’d Changing Open/Close Schedule Limits ? Time Holiday Daylight Open/close Hstg Quit CurrentHoliday Description and Dates Adding or Changing Holiday DescriptionsSystem Programming cont’d Group/Point Descriptions Changing Holiday DatesSystem Programming cont’d Turning On ALL Burglary Groups System OperationTurning On Burglary Protection Turning On One or More Burglary Groups Lesson Turn on See alarms Reset Quit MoreSystem Operation cont’d Turning Off Burglary Protection Are on Turn Off MenuTurning Off ALL Burglary Groups Continue Turn OffResetting Current Alarms Viewing the History Log System History LogTriggering a Panic Printing the History Log History Selection MenuOn this screen On printer Quit History Log Alpha and Event Codes Description Alpha System EventDescription Alpha Expansion Module Description Alpha Description Alpha Panic Description Alpha Other Access Bypassing/Unbypassing Burglary Protection Bypassing Protection Points Bypass Selection MenuGroup Selection Menu Group Description PreviousNext QuitBypassing/Unbypassing Vault Vibration Sensors VVS Quit Bypass VVSUnbypassing Protection Points Extending Close Time Sending Messages to a Pager System Test Burglary Protection Points AudibleSystem Test cont’d Protection Points VisualTesting Holdup, Fire, and Supervisory Devices Protection GroupsBell and Operating Panel Display Troubleshooting Guide Trouble or Error Display Description ActionTroubleshooting Guide cont’d Time to turn on ‘Group Description’ or extend closing timeFire, SPV or Holdup points bypassed ADT’s Focus 200 Plus Fire Alarm System Capabilities Fire Alarm Application NoteAbout Fire Alarm Codes Code EnforcementEmergency Evacuation Federal Communications Commission FCC Part 15 Statement Notification Federal Communications Commission FCC Part 68 Notice Canadian Department of Communications DOC Statement Limitations of this Alarm System Limitations of this Alarm System ADT Service personnel working on system76 IndexLimitations of this Alarm System ÊK3693-1SIA†Š