Bryant 580F 802 370 912 489, 624, 773, 935, 840 432 947 557, 696, 848, 878 502 982 632, 776, 864

Page 29

Table 18 — Fan Performance 580F060 — Three-Phase, Vertical Discharge Units,

Alternate Motor (Belt Drive)*

AIRFLOW

 

 

 

 

 

EXTERNAL STATIC PRESSURE (in. wg)

 

 

 

 

 

 

0.2

 

 

0.4

 

 

0.6

 

 

0.8

 

 

1.0

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

1500

802

0.42

370

912

0.55

489

1006

0.70

624

1088

0.87

773

1163

1.05

935

1600

840

0.49

432

947

0.63

557

1038

0.78

696

1119

0.95

848

1193

1.14

1013

1700

878

0.57

502

982

0.71

632

1071

0.87

776

1151

1.05

932

1224

1.24

1100

1800

917

0.65

581

1017

0.81

716

1105

0.97

864

1183

1.15

1024

1255

1.35

1197

1900

956

0.75

668

1053

0.91

808

1139

1.08

961

1216

1.27

1126

1287

1.47

1302

2000

995

0.86

764

1090

1.02

910

1173

1.20

1067

1249

1.39

1236

1319

1.59

1416

2100

1035

0.98

869

1127

1.15

1021

1209

1.33

1183

1283

1.53

1357

1351

1.74

1541

2200

1075

1.11

984

1164

1.29

1141

1244

1.47

1309

1317

1.68

1488

1385

1.89

1676

2300

1115

1.25

1110

1202

1.43

1273

1280

1.63

1446

1352

1.83

1629

1418

2.05

1822

2400

1155

1.40

1246

1240

1.59

1415

1316

1.79

1594

1387

2.01

1782

1452

2.23

1980

2500

1196

1.57

1394

1278

1.77

1569

1353

1.97

1753

1422

2.19

1946

 

 

 

 

 

 

 

 

 

 

 

 

AIRFLOW

 

 

 

 

 

EXTERNAL STATIC PRESSURE (in. wg)

 

 

 

 

 

 

1.2

 

 

1.4

 

 

1.6

 

 

1.8

 

 

2.0

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

1500

1232

1.25

1109

1297

1.46

1295

1357

1.68

1492

1415

1.91

1700

1469

2.16

1917

1600

1262

1.34

1190

1325

1.55

1379

1385

1.78

1579

1442

2.01

1788

1496

2.26

2009

1700

1291

1.44

1281

1354

1.66

1472

1414

1.89

1674

1470

2.12

1887

1524

2.37

2109

1800

1322

1.55

1380

1384

1.77

1575

1443

2.00

1779

1499

2.25

1994

1900

1352

1.68

1489

1414

1.90

1687

1472

2.13

1894

1528

2.38

2112

2000

1384

1.81

1607

1445

2.04

1808

1502

2.27

2019

2100

1415

1.95

1736

1476

2.18

1940

2200

1448

2.11

1875

1507

2.35

2083

2300

1480

2.28

2025

2400

2500

LEGEND

Bhp — Brake Horsepower Input to Fan

Watts — Input Watts to Motor

*Motor drive range: 878 to 1192 rpm. All other rpms require a field- supplied drive.

NOTES:

1.Boldface indicates field-supplied drive is required.

2.Maximum continuous bhp is 2.40.

3.See page 36 for general fan performance notes.

Table 19 — Fan Performance 580F060 — Vertical Discharge Units, High-Static Motor (Belt Drive)*

AIRFLOW

 

 

 

 

 

EXTERNAL STATIC PRESSURE (in. wg)

 

 

 

 

 

 

0.2

 

 

0.4

 

 

0.6

 

 

0.8

 

 

1.0

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

1500

802

0.42

370

912

0.55

489

1006

0.70

624

1088

0.87

773

1163

1.05

935

1600

840

0.49

432

947

0.63

557

1038

0.78

696

1119

0.95

848

1193

1.14

1013

1700

878

0.57

502

982

0.71

632

1071

0.87

776

1151

1.05

932

1224

1.24

1100

1800

917

0.65

581

1017

0.81

716

1105

0.97

864

1183

1.15

1024

1255

1.35

1197

1900

956

0.75

668

1053

0.91

808

1139

1.08

961

1216

1.27

1126

1287

1.47

1302

2000

995

0.86

764

1090

1.02

910

1173

1.20

1067

1249

1.39

1236

1319

1.59

1416

2100

1035

0.98

869

1127

1.15

1021

1209

1.33

1183

1283

1.53

1357

1351

1.74

1541

2200

1075

1.11

984

1164

1.29

1141

1244

1.47

1309

1317

1.68

1488

1385

1.89

1676

2300

1115

1.25

1110

1202

1.43

1273

1280

1.63

1446

1352

1.83

1629

1418

2.05

1822

2400

1155

1.40

1246

1240

1.59

1415

1316

1.79

1594

1387

2.01

1782

1452

2.23

1980

2500

1196

1.57

1394

1278

1.77

1569

1353

1.97

1753

1422

2.19

1946

1486

2.42

2149

 

 

 

 

 

 

 

 

 

 

 

 

AIRFLOW

 

 

 

 

 

EXTERNAL STATIC PRESSURE (in. wg)

 

 

 

 

 

 

1.2

 

 

1.4

 

 

1.6

 

 

1.8

 

 

2.0

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

1500

1232

1.25

1109

1297

1.46

1295

1357

1.68

1492

1415

1.91

1700

1469

2.16

1917

1600

1262

1.34

1190

1325

1.55

1379

1385

1.78

1579

1442

2.01

1788

1496

2.26

2009

1700

1291

1.44

1281

1354

1.66

1472

1414

1.89

1674

1470

2.12

1887

1524

2.37

2109

1800

1322

1.55

1380

1384

1.77

1575

1443

2.00

1779

1499

2.25

1994

1552

2.50

2219

1900

1352

1.68

1489

1414

1.90

1687

1472

2.13

1894

1528

2.38

2112

1580

2.63

2339

2000

1384

1.81

1607

1445

2.04

1808

1502

2.27

2019

1557

2.52

2240

1609

2.78

2470

2100

1415

1.95

1736

1476

2.18

1940

1533

2.43

2155

1587

2.68

2378

2200

1448

2.11

1875

1507

2.35

2083

1563

2.59

2301

1617

2.85

2528

2300

1480

2.28

2025

1539

2.52

2237

1595

2.77

2459

2400

1513

2.46

2187

1571

2.71

2403

2500

1547

2.66

2360

LEGEND

Bhp — Brake Horsepower Input to Fan

Watts — Input Watts to Motor

*Motor drive range: 1300 to 1685 rpm. All other rpms require a field-supplied drive.

NOTES:

1.Boldface indicates field-supplied drive is required.

2.Maximum continuous bhp is 2.90.

3.See page 36 for general fan performance notes.

29

Image 29
Contents Contents Important Read Before InstallingSafety Considerations InstallationBase Unit Dimensions 580F036-072 Base Unit Dimensions 580F073 Alternate Unit Support III. Install External Trap for CONDEN- Sate DrainII. Field Fabricate Ductwork IV. RIG and Place UnitConnector ALT Accessory Drain GAS Unit Size Accessory CRRFCURB001A01PKG. Accy Hole Power CRRFCURB002A01VI. Install GAS Piping Install Flue HoodRigging Details Unit 580F MAX WeightPhysical Data Freeze Protection Thermostat F Furnace SectionOUTDOOR-AIR Inlet Screens RETURN-AIR FiltersField Control Wiring Field Power SupplyHeat Anticipator Settings VII. Make Electrical ConnectionsPower Wiring Connections RLA LRA FLA MCA MOCP† Electrical Data Without Convenience OutletElectrical Data With Convenience Outlet Manual Outdoor-Air Damper VIII. Adjust FACTORY-INSTALLED OptionsBracket Optional EconoMi$er+Hood BOX IAQ OarhOAT IarhThermostats EconoMi$er+ Controller WiringDamper Movement Outdoor Air Temperature OAT Sensor Provided EconoMi$er+ Field-Installed AccessoriesSupply Air Temperature SAT Sensor Provided Return Air Temperature RAT SensorOutdoor Air Humidity Sensor Indoor Air Quality Voltage SettingRange Resolution Temperature ResistanceEnthalpy Changeover Settings Power Exhaust Occupied/Unoccupied SwitchRemote EconoMi$er+ Enable Control Indoor Air Humidity SensorFull Occupancy CO2 Sensor ConfigurationVentilation Rate Ventilation for PeopleBelt-Drive Motors IX. Adjust EVAPORATOR-FAN SpeedDirect-Drive Motors Motor Data Fan Rpm at Motor Pulley Settings768 External Static Pressure in. wg Cfm Rpm Bhp Watts 900870 958955 External Static Pressure in. wg Cfm Rpm Bhp Watts1181 970 1073840 432 Low Speed802 370 624 802 370 912 489773 935663 967 579757 856Bhp Watts 900 Airflow Low Speed High Speed884 941762 705 859 458 944 579886 517 969 644 777828 413 790 353866 479 790 353 896 470 990 599866 479 964 607 1053 746 828 413 930 535 1021 669905 553 1000 687 1085 831 944 635 1036 775 1119 924867 771986 966VI. Refrigerant Service Ports IV Internal WiringPRE-START-UP START-UP Unit PreparationXI. Heating IX. CoolingMain Burners XIV. ECONOMI$ER+ Controller XII. Safety ReliefXIII. Ventilation Continuous FAN Input Name Type USE INPUT/OUTPUT Conversion Connection PIN DS1 DS2 DS3 DS4Thermostat Inputs Economizer MotorInput/Output Channels Start-Up Mode SequenceConfiguration Variables Read and Setup Modes Setup Mode XV. ECONOMI$ER+ Configuration Manual ModeError Mode Ventilation Air and Free Cooling Compressor Configuration and ControlPower Exhaust Configuration Demand Ventilation ConfigurationXVI. Operating Sequence Cooling, Units without EconoMi$er+Cooling, Units with EconoMi$er+ Heating, Units without EconoMi$er+Service Cleaning ECONOMI$ER+ Adjustment III. Blower Belt AdjustmentII. Lubrication IV. Manual OUTDOOR-AIR DamperXIII. HIGH-PRESSURE Switch Limit SwitchXIV. Loss of Charge Switch XVI. Replacement PartsSuction Line Temperature DEG. F Suction Line Temperature DEG. CSuction Line Pressure Kilopascals Suction Line Pressure PsigTON Unit 60 Hz Charging Chart Burner Section Details Troubleshooting ECONOMI$ER+ Troubleshooting Unit Always in Unoccupied Mode Error Code 8 E2 Test FailureII. Unit Troubleshooting RAM Test FailureHeating Service Analysis LED Error Code Service AnalysisCooling Service Analysis GND FPTGVR HPSAppendix a ECONOMI$ER+ Label Startup ModeAppendix a ECONOMI$ER+ Label Appendix B JOB Specific ECONOMI$ER+ Configuration Settings Index Call for Free Catalog Service TrainingPage Temperatures START-UP ChecklistPreliminary Information III. START-UP Electrical
Related manuals
Manual 80 pages 29.14 Kb Manual 52 pages 44.41 Kb

580F specifications

The Bryant 580F is a highly regarded gas furnace known for its exceptional heating performance and advanced technology. Designed for residential use, this model stands out for its reliability, efficiency, and user-friendly features that cater to modern heating demands.

One of the most notable features of the Bryant 580F is its efficiency rating. With an AFUE (Annual Fuel Utilization Efficiency) rating of up to 95%, this furnace maximizes heat output while minimizing energy consumption. This high level of efficiency not only results in lower utility bills but also reduces the environmental impact—a critical consideration for today’s eco-conscious homeowners.

The Bryant 580F is equipped with a multi-speed blower that ensures consistent airflow and enhances comfort by maintaining even temperatures throughout the home. This technology allows the furnace to adjust its operation based on the heating needs, leading to quieter operation and increased comfort levels.

In terms of construction, the Bryant 580F is built with durable materials that promise longevity and resilience against wear and tear. Its compact design makes installation easier, allowing it to fit into tight spaces without compromising its performance.

One of the standout technologies integrated into the Bryant 580F is its enhanced control system. The furnace works seamlessly with smart thermostats, allowing homeowners to monitor and adjust heating settings from their mobile devices. This feature not only provides convenience but also allows for energy-saving optimizations based on personal schedules and preferences.

Safety is also a primary concern with the Bryant 580F. It includes robust safety features such as a hot surface ignition system that eliminates the need for a standing pilot light, reducing the risk of gas leaks. Additionally, advanced diagnostics help in troubleshooting and maintenance, ensuring that potential issues can be identified and resolved quickly.

In conclusion, the Bryant 580F gas furnace is a remarkable choice for those seeking a blend of efficiency, comfort, and advanced technology. Its high AFUE rating, multi-speed blower, smart control compatibility, and safety features make it a reliable option for homeowners looking to invest in a dependable heating solution. As the demand for energy-efficient heating continues to grow, the Bryant 580F stands out as a model that meets and exceeds expectations in the modern heating landscape.