Bryant 580F installation instructions Fpt, Gnd, Gvr, Hps, Idm, Ifc, Ifm, Igc, Lps, Mgv, Tran

Page 57

NOTES:

1. If any of the original wire furnished must be replaced, it must be replaced with type 90 C wire or its equivalent.

2. Three phase motors are protected under primary single phasing conditions.

4. Use copper conductors only.

6. TRAN is wired for 230 v unit. If unit is to be run with 208 v power supply, disconnect BLK wire from 230 v tap (ORN) and connect to 208 v tap (RED). Insulate end of 230 v tap.

LEGEND

CContactor, Compressor CAP — Capacitor

COMP — Compressor Motor EQUIP — Equipment

FPT

Freeze Up Protection Thermostat

FU

Fuse

GND

Ground

GVR

Gas Valve Relay

HPS

High-Pressure Switch

HS

Hall-Effect Sensor

IIgnitor

IDM

Induced-Draft Motor

IFC

Indoor Fan Contactor

IFM

Indoor (Evaporator) Fan Motor

IGC

Integrated Gas Unit Controller

LPS

Low-Pressure Switch

LS

Limit Switch

MGV

Main Gas Valve

OFM — Outdoor (Condenser) Fan Motor OLR — Overload Relay

PPlug

PL

Plug Assembly

QT

Quadruple Terminal

RS

Rollout Switch

SAT

Supply Air Temperature Sensor

TRAN

Transformer

 

Field Splice

 

Marked Wire

 

Terminal (Marked)

 

Terminal (Unmarked)

 

Terminal Block

Fig. 48 — Typical Unit Wiring Diagram

57

Splice

Splice (Marked)

Factory Wiring

Field Control Wiring

Field Power Wiring

Accessory or Optional Wiring

To indicate common potential only; not to represent wiring.

Image 57
Contents Contents Important Read Before InstallingSafety Considerations InstallationBase Unit Dimensions 580F036-072 Base Unit Dimensions 580F073 Alternate Unit Support III. Install External Trap for CONDEN- Sate DrainII. Field Fabricate Ductwork IV. RIG and Place UnitConnector ALT Accessory Drain GAS Unit Size Accessory CRRFCURB001A01PKG. Accy Hole Power CRRFCURB002A01VI. Install GAS Piping Install Flue HoodRigging Details Unit 580F MAX WeightPhysical Data Freeze Protection Thermostat F Furnace SectionOUTDOOR-AIR Inlet Screens RETURN-AIR FiltersField Control Wiring Field Power SupplyHeat Anticipator Settings VII. Make Electrical ConnectionsPower Wiring Connections RLA LRA FLA MCA MOCP† Electrical Data Without Convenience OutletElectrical Data With Convenience Outlet Manual Outdoor-Air Damper VIII. Adjust FACTORY-INSTALLED OptionsOptional EconoMi$er+ Hood BOXBracket IAQ OarhOAT IarhEconoMi$er+ Controller Wiring Damper MovementThermostats Outdoor Air Temperature OAT Sensor Provided EconoMi$er+ Field-Installed AccessoriesSupply Air Temperature SAT Sensor Provided Return Air Temperature RAT SensorOutdoor Air Humidity Sensor Indoor Air Quality Voltage SettingRange Resolution Temperature ResistanceEnthalpy Changeover Settings Power Exhaust Occupied/Unoccupied SwitchRemote EconoMi$er+ Enable Control Indoor Air Humidity SensorFull Occupancy CO2 Sensor ConfigurationVentilation Rate Ventilation for PeopleIX. Adjust EVAPORATOR-FAN Speed Direct-Drive MotorsBelt-Drive Motors Motor Data Fan Rpm at Motor Pulley Settings768 External Static Pressure in. wg Cfm Rpm Bhp Watts 900870 958955 External Static Pressure in. wg Cfm Rpm Bhp Watts1181 970 1073Low Speed 802 370840 432 624 802 370 912 489773 935663 967 579757 856Bhp Watts 900 Airflow Low Speed High Speed884 941762 705 859 458 944 579886 517 969 644 777828 413 790 353866 479 790 353 896 470 990 599866 479 964 607 1053 746 828 413 930 535 1021 669905 553 1000 687 1085 831 944 635 1036 775 1119 924867 771986 966VI. Refrigerant Service Ports IV Internal WiringPRE-START-UP START-UP Unit PreparationIX. Cooling Main BurnersXI. Heating XII. Safety Relief XIII. Ventilation Continuous FANXIV. ECONOMI$ER+ Controller Input Name Type USE INPUT/OUTPUT Conversion Connection PIN DS1 DS2 DS3 DS4Thermostat Inputs Economizer MotorStart-Up Mode Sequence Configuration Variables Read and Setup ModesInput/Output Channels Setup Mode Manual Mode Error ModeXV. ECONOMI$ER+ Configuration Ventilation Air and Free Cooling Compressor Configuration and ControlPower Exhaust Configuration Demand Ventilation ConfigurationXVI. Operating Sequence Cooling, Units without EconoMi$er+Cooling, Units with EconoMi$er+ Heating, Units without EconoMi$er+Service Cleaning ECONOMI$ER+ Adjustment III. Blower Belt AdjustmentII. Lubrication IV. Manual OUTDOOR-AIR DamperXIII. HIGH-PRESSURE Switch Limit SwitchXIV. Loss of Charge Switch XVI. Replacement PartsSuction Line Temperature DEG. F Suction Line Temperature DEG. CSuction Line Pressure Kilopascals Suction Line Pressure PsigTON Unit 60 Hz Charging Chart Burner Section Details Troubleshooting ECONOMI$ER+ Troubleshooting Unit Always in Unoccupied Mode Error Code 8 E2 Test FailureII. Unit Troubleshooting RAM Test FailureHeating Service Analysis LED Error Code Service AnalysisCooling Service Analysis GND FPTGVR HPSAppendix a ECONOMI$ER+ Label Startup ModeAppendix a ECONOMI$ER+ Label Appendix B JOB Specific ECONOMI$ER+ Configuration Settings Index Call for Free Catalog Service TrainingPage Temperatures START-UP ChecklistPreliminary Information III. START-UP Electrical
Related manuals
Manual 80 pages 29.14 Kb Manual 52 pages 44.41 Kb

580F specifications

The Bryant 580F is a highly regarded gas furnace known for its exceptional heating performance and advanced technology. Designed for residential use, this model stands out for its reliability, efficiency, and user-friendly features that cater to modern heating demands.

One of the most notable features of the Bryant 580F is its efficiency rating. With an AFUE (Annual Fuel Utilization Efficiency) rating of up to 95%, this furnace maximizes heat output while minimizing energy consumption. This high level of efficiency not only results in lower utility bills but also reduces the environmental impact—a critical consideration for today’s eco-conscious homeowners.

The Bryant 580F is equipped with a multi-speed blower that ensures consistent airflow and enhances comfort by maintaining even temperatures throughout the home. This technology allows the furnace to adjust its operation based on the heating needs, leading to quieter operation and increased comfort levels.

In terms of construction, the Bryant 580F is built with durable materials that promise longevity and resilience against wear and tear. Its compact design makes installation easier, allowing it to fit into tight spaces without compromising its performance.

One of the standout technologies integrated into the Bryant 580F is its enhanced control system. The furnace works seamlessly with smart thermostats, allowing homeowners to monitor and adjust heating settings from their mobile devices. This feature not only provides convenience but also allows for energy-saving optimizations based on personal schedules and preferences.

Safety is also a primary concern with the Bryant 580F. It includes robust safety features such as a hot surface ignition system that eliminates the need for a standing pilot light, reducing the risk of gas leaks. Additionally, advanced diagnostics help in troubleshooting and maintenance, ensuring that potential issues can be identified and resolved quickly.

In conclusion, the Bryant 580F gas furnace is a remarkable choice for those seeking a blend of efficiency, comfort, and advanced technology. Its high AFUE rating, multi-speed blower, smart control compatibility, and safety features make it a reliable option for homeowners looking to invest in a dependable heating solution. As the demand for energy-efficient heating continues to grow, the Bryant 580F stands out as a model that meets and exceeds expectations in the modern heating landscape.