Only For Qualified Installers | Installation |
|
|
Converting to Natural Gas |
|
1 | Door Hooks | 3 |
|
|
15
Door Latches
Remove door by pulling latches out as shown and pulling the bottom of the door out from the unit about 3”. Then lift the door slightly up and off the hooks.
2
Remove log. Next, remove screw, washer and spacer from the center of the rear brick panel. Using one hand, gently push the side brick/relief door open slightly and using the other pull the top of the rear brick panel forward and remove it.
Remove air plate by lifting it up about 3 inches and then out of firebox. Be careful not to damage side brick panels
4
Remove the screws mounting the intake air deflector and lift it from the firebox. Next locate the screw holding the burner tube to the firebox floor and remove it. Now the #50 LPG burner orifice can be removed using a 1/2” deep well socket and replaced with a # 31 natural gas orifice.
Remove screw holding pilot air deflectors, and the deflectors, to allow access to the pilot tower. using a 7/16” wrench, take out the LP orifice and replace it with the natural gas orifice. Reassemble components adjusting pilot air deflectors allowing burner tube to slide over them and into place. Pilot orfices are marked NG and LP appropriately.
Burner
Pilot
The pilot must be placed in accordance with the above sketch for proper burner ignition.