Harman Stove Company XL owner manual Burner Pilot

Page 15

Only For Qualified Installers

Installation

 

 

Converting to Natural Gas

 

1

Door Hooks

3

 

 

15

Door Latches

Remove door by pulling latches out as shown and pulling the bottom of the door out from the unit about 3”. Then lift the door slightly up and off the hooks.

2

Remove log. Next, remove screw, washer and spacer from the center of the rear brick panel. Using one hand, gently push the side brick/relief door open slightly and using the other pull the top of the rear brick panel forward and remove it.

Remove air plate by lifting it up about 3 inches and then out of firebox. Be careful not to damage side brick panels

4

Remove the screws mounting the intake air deflector and lift it from the firebox. Next locate the screw holding the burner tube to the firebox floor and remove it. Now the #50 LPG burner orifice can be removed using a 1/2” deep well socket and replaced with a # 31 natural gas orifice.

Remove screw holding pilot air deflectors, and the deflectors, to allow access to the pilot tower. using a 7/16” wrench, take out the LP orifice and replace it with the natural gas orifice. Reassemble components adjusting pilot air deflectors allowing burner tube to slide over them and into place. Pilot orfices are marked NG and LP appropriately.

Burner

Pilot

The pilot must be placed in accordance with the above sketch for proper burner ignition.

Image 15
Contents Direct Vent Gas Fireplace Insert ShadowLight XLAdvetissement Quinconque ne respect pas Table of Contents Introduction Specifications Specifications Ratings Natural Propane Door Handles OperationOperation HOW to Turn OFF the Fire Inside the Insert Box Inside Face Box Packing ListInstallation LP Gas Making The ConnectionGas Pressure Requirements Natural GasThese kits are only for use ShadowLight XL Insert Converting to Natural GasBurner Pilot Installation Converting to High Altitude Use Only Approved Venting VentingFlashing Chimney Cap ComponentsVenting and Installation Flue Installation Installation Check List Remote Control Connecting Optional ThermostatRemoving the Glass Door Cleaning the GlassCleaning the Log Set and Firebox Replacing the Glass and GasketReplacing The Blower Cleaning the BurnersWiring Diagrams Shadowlight XL Parts Burner Module Parts Inlet Pressure To 13 inches Manifold Pressure Natural Gas InchesInlet Pressure To 7 inches Propane Manifold Pressure InchesBad Yes BadYes Pilot does not stay lit Bad GoodLight pilot Main Burner will not light with valve in on positionHarman Gold Warranty