16 Installation | Only For Qualified Installers | |
|
|
|
5
Remove three screws to change knob assembly. Install NG knob assembly in place of the LP assembly. Be sure screws are tight.
6
Place conversion sticker (provided in Kit) on the valve. This is to permanently mark the valve that it has been converted to Natural Gas. This label is important in the event that the valve is ever removed and mixed in with other valves. Reassemble all components removed during the conversion process.
7
Mark the proper box on the fuel label with a permanent marker. Note: If no conversion is made, the box for propane must still be marked.
Safety Label
8
When installation has been completed, verify the gas inlet and manifold pressures are within specifications. The safety label, located inside the bottom of the unit, will have the information needed to verify correct operation. To read the safety label, pull the label out away from the unit. Be sure to use the information for the type of gas that it will be using.
You must check the unit for any gas leaks using soapy water or an electronic style leak detector.
Use soap and water and/or a gas detector to check for leaks before lighting the pilot.