Harman Stove Company XL owner manual Introduction

Page 4

4

Introduction

The installation of the ShadowLight XL Fireplace Insert must conform with local codes, or in the absence of local codes, with National Fuel Gas Code, ANSI Z233.1 (NFPA 54). Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les Codes d'installation CAN/CGA-B149.

The ShadowLight XL Fireplace Insert may be installed in mobile homes.

CAUTION: This appliance must be vented to the outside.

Installation and repair of the ShadowLight XL Fireplace Insert should be done by a qualified service person. The appliance should be inspected before use and at least annually by a qualified service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that control compartments, burners, and circulating air passageways of the appliance be kept clean. Any safety screen or guard removed for servicing an appliance must be replaced prior to operating the appliance.

S'ASSURERQUELEBRÛLEURETLECOMPARTIMENT DES COMMANDES SONT PROPRES. VOIR LES INSTRUCTIONS D'INSTALLATION ET D'UTILISATION QUI ACCOMPAGNENT L'APPAREIL.

When operating your Harman ShadowLight XL Fireplace Insert, respect basic safety standards.

Read these instructions carefully before you attempt to operate the heater. Failure to do so may result in damage to property or personal injury and may void the product warranty.

Consult with your local building code agency and insurance representative before you begin your installation to ensure compliance with local codes, including the need for permits and follow-up inspections.

Observing required clearances to combustible materials, proper connection to an approved venting system, and the accessibility of the gas and electrical supply must all be considered when planning the installation of a ShadowLight XL Fireplace Insert.

Install the ShadowLight XL Fireplace Insert only in a listed solid-fuel burning factory-built fireplace or a masonry solid-fuel burning fireplace. The Fireplace Insert and vent should be enclosed when installed in, or when passing through, a living area where children may come in contact with it.Z21.88-2002-CSA 2.33- 2002,CAN/CGA2.17.

Listed Direct Vent Gas Fireplace Heater

Radiateur Ventile

Model: ShadowLight XL Gas Fireplace Insert

WHI #

• Homologue Pour Le Canada

• Do not remove this label.

Not for use with solid fuel. Not for use with air filters. Ne doit pas etre utilise avec un combustible solide.

Also for use in mobile (manufactured) homes after home is sited.

Tested to ANSI Z21.88-2002 / CSA2.33-2002 / CAN-CGA-2.17-M91

For use with natural gas or propane. A conversion kit, as supplied by the manufacturer, shall be used to convert this room heater to the alternate fuel. Pour utilisation, avec le gaz naturel et le propane. Une trousse de conversion fournie par le fabricant doit etre utilisee pour passer d’un combustible a l’autre.

Keep burner and control compartment clean. See installation and operating instructions accompanying appliance. S’assurer que le bruleur et le compartiment des commandes sont propres. Voir les instructions d’installation et d’utilisation qui accompagnent l’appareil.

During repairs or maintenance of this unit, all sealing gaskets or high temperature silicone seals on the heat exchanger module must be in- spected for damage and replaced, if necessary, to prevent any leakage of exhaust into the living areas.

Electrical Rating: 115 VAC, 60 Hz, < 1.15 AMP

RATINGS

NATURAL

PROPANE

Input Rating(Btu/hr)(0-2000 ft)(0-610m)

35,000

35,000

Input Rating(Btu/hr)(2000-4500ft)(610-1375m)

34,000

34,500

Min. Input Rating(Btu/hr)

21,600

20,900

Orifices (DMS)(0-2000 ft)(0-610m)

31

50

Orifices (DMS)(2000-4500ft)(610-1375m)

33

51

Manifold Pressure (in w.c./kPa)

3.5/.87

2.5

Min. Manifold Pressure (in w.c./kPa)

1.3/.32

3.6/.9

Min. Inlet Pressure (in w.c./kPa)

5.0/1.24

11.0/2.75

MANTEL CLEARANCE: Combustible mantle up to 8” in depth must be at least 43” above unit base.

CAUTION: Do not operate the appliance with glass removed, cracked or broken. Replacement of panel(s) should be done by a licensed or qualified service person.

CAUTIONNER: N’orére l’appareil avec le verre enlevé, craque ou casse. Le remplacement du panneau(s) devrait être fait par une personne de

service qualifie ou autorise.

CAUTION: Hot while in operation. Do not touch. Severe burns may result. Keep children, clothing, furniture, gasoline and other liquids having flammable vapors away.

ATTENTION: Les surfaces sont chaudes en service. Ne touchez pas. Risque de brulure grave. Tenez les enfants, les vatements, le mobilier, l’essence et autres liquides produisant des vapeurs inflammables B distance.

This appliance is only for use with the type of gas indicated on the rat- ing plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited by local codes. See owner’s manual for details. This appliance is not convertible for use with other gases, unless a certified kit is used.

A LABEL (LOCATED NEAR THE BURNER SYSTEM MOD- ULE) STATES THE FUEL FOR WHICH THE HEATER IS EQUIPPED.

Manufactured by Harman Stove Company 352 Mountain House Road, Halifax, PA 17032 20 Airport Road, West Lebanon, NH 03784

SAFETY LABEL

Image 4
Contents ShadowLight XL Direct Vent Gas Fireplace InsertAdvetissement Quinconque ne respect pas Table of Contents Introduction Specifications Specifications Ratings Natural Propane Operation Door HandlesOperation HOW to Turn OFF the Fire Packing List Inside the Insert Box Inside Face BoxInstallation Making The Connection Gas Pressure RequirementsNatural Gas LP GasConverting to Natural Gas These kits are only for use ShadowLight XL InsertBurner Pilot Installation Converting to High Altitude Venting Use Only Approved VentingChimney Cap Components FlashingVenting and Installation Flue Installation Installation Check List Connecting Optional Thermostat Remote ControlCleaning the Glass Cleaning the Log Set and FireboxReplacing the Glass and Gasket Removing the Glass DoorCleaning the Burners Replacing The BlowerWiring Diagrams Shadowlight XL Parts Burner Module Parts Manifold Pressure Natural Gas Inches Inlet Pressure To 7 inchesPropane Manifold Pressure Inches Inlet Pressure To 13 inchesYes Bad BadYes Good Pilot does not stay lit BadMain Burner will not light with valve in on position Light pilotHarman Gold Warranty