Heat & Glo LifeStyle SLR32 D. Disassemble Vent Sections, E. Install Decorative Ceiling Components

Page 41
D. Disassemble Vent Sections

D. Disassemble Vent Sections

Rotate either section (see Figure 10.7) so the seams on both pipe sections are aligned as shown in Figure 10.8.

Pull carefully to separate the pieces of pipe.

Figure 10.7 Rotate Seams for Disassembly

Figure 10.8 Align and Disassemble Vent Sections

E. Install Decorative Ceiling Components

A decorative ceiling thimble can be installed on a flat ceil- ing through which the vent passes. The decorative ceiling thimble is used to cover the firestop.

Seal the gap between the vent pipe and firestop using silicone with a minimum of 300ºF continuous exposure rating to prevent cold air infiltration.

Install the decorative ceiling thimble by sliding it up to the ceiling and attaching it using the provided screws.

A decorative cathedral ceiling support box can be installed on a cathedral ceiling through which the vent passes.

Use a plumb-bob to mark the center line of the venting system on the ceiling and drill a small hole through the ceiling and roof at this point. Locate the hole and mark the outline of the cathedral ceiling support box on the outside roof.

Remove shingles or other roof covering as necessary to cut the rectangular hole for the support box. Cut the hole 1/8 in. (3 mm) larger than the support box outline.

Lower the support box through the hole in the roof until its bottom is at least 2 in. (51 mm) below the ceiling (Figure

10.9).

Level the support box both vertically and horizontally and temporarily tack it in place through the inside walls into the roof sheathing.

Use tin snips to cut the support box from the top corners down to the roof line and fold the resulting flaps to the roof. See Figure 10.10.

Nail the flaps to the roof AFTER running a bead of non hardening sealant between the flaps and the roof.

WARNING! Risk of Fire! Clean out ALL materials from inside the support box and complete the vertical vent run and termination.

LEVEL

CATHEDRAL CEILING

SUPPORT BOX

2 in. (51 mm) MIN. BELOW FINISHED CEILING

CUT HOLE 1/8 in. (3 mm)

GREATER IN SIZE THAN

PATTERN OF SUPPORT

BOX AS IT IS PROJECTED

ONTO ROOF LINE

Figure 10.9

Figure 10.10

Heat & Glo • SLR32 • 2269-900 Rev. E • 4/12

41

Image 41
Contents Model SLR32 NOTICE•What to do if you smell gas Owner’s ManualHomeowner Reference Information A. CongratulationsSafety Alert Key Table of ContentsInstaller Guide 3 Maintenance and Service15 Troubleshooting 14 Appliance Setup = Contains updated information 13 FinishingLIMITED LIFETIME WARRANTY B. Limited Lifetime WarrantyWARRANTY COVERAGE WARRANTY PERIODWARRANTY CONDITIONS B. Limited Lifetime Warranty continuedWARRANTY EXCLUSIONS This warranty is void if1 Listing and Code Approvals D. High Altitude InstallationsA. Appliance Certification B. Tempered Glass SpecificationsInstallation of Carbon Monoxide Detectors 2 Operating Instructions User Guide A. Gas Fireplace SafetyB. Your Fireplace WARNING! Choking Hazard! Keep glass rock mediaC. Clear Space E. Fixed Glass AssemblyD. Decorative Doors and Fronts G. Before Lighting FireplaceFinal inspection by H. Lighting Instructions IPIFOR YOUR SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONS IPII. After Fireplace is Lit J. Frequently Asked QuestionsInitial Break-inProcedure •Some people may be sensitive to smoke and odorsA. Maintenance Tasks-Homeowner 3 Maintenance and ServiceGlass Cleaning Remote ControlGasket Seal and Glass Assembly Inspection B.Maintenance Tasks-QualifiedService TechnicianVenting FireboxA. Typical Appliance System Getting StartedInstaller Guide WALL SWITCHD. Inspect Appliance and Components B. Design and Installation ConsiderationsC. Tools and Supplies Needed A. Selecting Appliance Location 5 Framing and ClearancesHeat & Glo • SLR32 • 2269-900Rev. E • 4/12 B. Constructing the Appliance ChaseMINIMUM FRAMING DIMENSIONS C. ClearancesCombustible Mantels D. Mantel and Wall ProjectionsNon-combustibleMantels Front Side Finishing Detail5 IN Figure 5.8 Non-CombustibleZoneWALL SHEATHINGA. Vent Termination Minimum Clearances 6 Termination LocationsV= VENT TERMINAL X = AIR SUPPLY INLET = AREA WHERE TERMINAL IS NOT PERMITTEDCovered Alcove Applications E. Vent Diagrams 7 Vent Information and DiagramsA. Approved Pipe B. Vent Table KeyVenting with 1 elbow Top Vent - Horizontal TerminationVenting with 2 elbows 1. Top Vent - Horizontal Termination - continuedINSTALLED HORIZONTALLY Top Vent - Horizontal TerminationTop Vent - Horizontal Termination 1. Top Vent - Horizontal Termination - continuedVenting with 3 elbows H2 V2 H1V1 = 44 ft. Max. 13.4 m Top Vent - Vertical Termination No ElbowsExhaust restrictor Instructions PILOT HOLESVenting with 2 elbows Top Vent - Vertical TerminationSLR32 V1 MinimumTop Vent - Vertical Termination Venting with 3 elbowsSLR32 V1 MinimumTop Vent - Vertical Termination Venting with 4 elbowsV3 H2 H1 V1 V1 MINPrior to installing the gas appliance Coaxial to Colinear VentingTable Clearances to Combustibles•Use separate vent system for this appliance TOP VENT•Vent this appliance directly outside A. Pipe Clearances to Combustibles 8 Vent Clearances and FramingB. Wall Penetration Framing Between ceiling firestopsC. Install the Ceiling Firestop Vaulted Ceiling Installation D. Install Attic Insulation ShieldFlat Ceiling Installation A. Preparing Elbow Heat Shield 9 Appliance PreparationWARNING! Risk of Fire! Prevent contact with B. Securing and Leveling the Appliance•Sagging or loose insulation •Insulation backing or plasticA. Assemble Vent Sections 10 Installing Vent Pipe SLP PipePilot hole B. Assemble Slip SectionsC. Secure The Vent Sections D. Disassemble Vent Sections E. Install Decorative Ceiling ComponentsCAULK F. Install Metal Roof FlashingG. Assemble and Install Storm Collar I. Install Decorative Wall Components H. Install Vertical Termination CapFigure Figure 10.16 Wall ThimbleFigure 10.17 Venting through the wall K. Install Horizontal Termination CapA. Fuel Conversion 11 Gas InformationB. Gas Pressure Access Through the Valve AssemblyD. High Altitude Installations C. Gas ConnectionValve Pressure Taps •Ensure adequate ventilationB. IntelliFire Ignition System Wiring A. Wiring RequirementsC. Optional Accessories Requirements 12 Electrical InformationE. Junction Box Installation D. Electrical Service and RepairA. Framing and Finishing Instructions 13 FinishingSetting the Fireplace into the Framing Finishing InstructionsHeat & Glo • SLR32 • 2269-900Rev. E • 4/12 Figure 13.3 Finishing DetailsWallboard Joint-CrackPrevention and Repair PaintingFinish and Sealing Joints Finishing Around Opening with Gypsum WallboardCombustible Mantel Legs Or Wall Projections B. Mantel and Wall ProjectionsExtending Past The Face Of The Fireplace Failure to comply could cause fire0 - 1 inch thickness-OverlapFit Method C. Facing MaterialNon-CombustibleFinish Materials 0 Inches to 4 Inches Thick-InsideFit Method Non-CombustibleFinish MaterialsNon-CombustibleFinish Material 0-4Inches Thick 3/4 INTable 1. Dimensions of Tonic Decorative Front D. Decorative FrontsTable 1. Dimensions of Martini Decorative Front Figure 13.14 Dimensions of Tonic Decorative FrontA. Remove Fixed Glass Assembly 14 Appliance SetupC. Clean the Appliance D. Accessories• MEDIA-COBALT • MEDIA-BK2-GEMS • MEDIA-WH2-GEMS • MEDIA-AMBER • MEDIA-BLACK • MEDIA-CLEAR• MEDIA-STONES-2 • SLR32-LOGS • MEDIA-CL2-GEMS • GLASS32-LINERG. Install the Mesh F. Fixed Glass AssemblyH. Air Shutter Setting Removing Fixed Glass AssemblyA. IntelliFire Ignition System 15 TroubleshootingSymptom Possible CauseSymptom IntelliFire Ignition System - continuedPossible Cause Corrective Action16 Reference Materials A. Appliance Dimension DiagramN R Q S P M K L J I Ø A B E F C D9 in B. Vent Components Diagrams12-1/2in 2-3/4inEffective Height Length B. Vent Components Diagrams continuedSLP-45- 45 Elbow SLP90- 90 ElbowSLK-SNKD B. Vent Components Diagrams continuedSLP-CCS-BK SLP-TVHWHORIZONTAL TERMINATION CAP SLP-HRC-SS SLP-HRC-ZC-SSB. Vent Components Diagrams continued COAXIAL to COLINEAR VENTINGOptional Wire Harness DESCRIPTIONat depot C. Service PartsSLR32 Stockedat Depot SLR32C. Service Parts #11 Valve AssemblyStocked SLR32C. Service Parts at DepotNOTICE D. Contact Information