IGNITION MODULE 3 VAC | INTERMITTENT PILOT IGNITOR |
HOT
BATTERY PACK
NEUTRAL
TRANSFORMER
3 VAC
PLUG IN | BLACK |
| |
| RED |
THERMOSTAT
WIRE ASSEMBLY
I
S
WHITE
ORANGE
GROUND TO
FIREPLACE
CHASSIS
WIRES
(TO BROWN)
ORANGE
VALVE
GREEN
NOTE: 1. Ignition module, valve, pilot, and wall switch operate on 3 volts. 120 VAC is required at junction box unless equipped with battery
Figure 12.2 IntelliFire Pilot Ignition (IPI) Wiring Diagram with Wall Switch or Thermostat
D. Electrical Service and Repair
WARNING! Risk of Shock! Label all wires prior to dis- connection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
WARNING! Risk of Shock! Replace damaged wire with type 105° C rated wire. Wire must have high temperature insulation.
E. Junction Box Installation
1.Bend junction box heat shield to the right along the perforated hand bends.
2.Remove the one screw located in front of the junction box.
3.Remove the plastic electrical knockout slug in the top of the junction box.
4.Install wire strain (not included) and route wire through wire strain fitting.
5.Make the connections inside the junction box to the 120V wire. Connect the green wire to the ground nut, the black wire to the black wire and the white wire to the white wire.
6.Reinstall the junction box.
7.Reposition the junction box heat shield such that it is positioned over the junction box.
Note: There is an alternative access to the junction box. This can be accessed by removing the valve assembly. See Section 11.
48 | Heat & Glo • SLR32 • |