Heat & Glo LifeStyle 6000TRI-SP Venting with Three 3 90 Elbows, Venting with three 90 elbows

Page 19

VENTING WITH THREE (3) 90° ELBOWS

 

V

 

H

H + H1

1´MIN. (305mm)

2´MAX. (610mm)

5´MAX. (1.52m)

2´MIN. (610mm)

4´MAX. (1.22m)

10´MAX. (3.1m)

3´MIN. (914mm)

6´MAX. (1.86m)

15´MAX. (4.65m)

4´MIN. (1.22m)

8´MAX. (2.48m)

20´MAX. (6.2m)

V1+V+H+H1

= 40´ MAX.(12.4 m) H = 8´MAX.(2.48 m) H+H1 = 20´MAX.(6.2 m)

V1

 

 

 

V

 

 

 

H1

 

 

 

H

 

 

 

V

H

 

H + H1 + H2

1´MIN. (305mm)

2´MAX. (610mm)

5´MAX. (1.52m)

2´MIN. (610mm)

4´MAX. (1.22m)

10´MAX. (3.1m)

3´MIN. (914mm)

6´MAX. (1.86m)

15´MAX. (4.65m)

4´MIN. (1.22m)

8´MAX. (2.48m)

20´MAX. (6.2m)

V+H+H1+H2 = 40´ MAX. (12.4 m)

H = 8´ MAX. (2.48 m)

H+H1+H2 = 20´ MAX. (6.2 m)

 

 

V

 

H2

 

 

 

H1

 

 

 

 

 

H

 

Figure 16. Venting with three 90° elbows

 

 

 

Heat & Glo • 6000TRI-IPI, 6000TRI-SP385-901 Rev. F • 5/05

19

Image 19
Contents What to do if you smell gas Installers GuideSafety and Warning Information Table of Contents 6000TRI-IPI, 6000TRI-SP Log set assembly6000TRI-SP, 6000TRI-IPI Service Parts List / Liste des pièces de rechange6000TRI-IPI Intermittent Pilot Ignition Valve Assembly6000TRI-SP Standing Pilot Ignition Valve AssemblyCertification Installation CodesHigh Altitude Installations Appliance CertificationIntroducing the Heat & Glo Gas Fireplaces Pre-install PreparationANY Such Action MAY Possibly Cause a Fire Hazard Diagram of the 6000TRI-IPI, 6000TRI-SP Locating the Fireplace Constructing the Fireplace ChaseClearance Requirements Framing the Fireplace Framing DimensionsDVP90ST Identifying Vent Components Installing the Vent SystemVent System Approvals Tems or Components MAY be UsedVertical Venting Flue Restrictor InstructionsMAX .4 M Straight Up Vertical Venting Chart Venting with One 90 Elbow Venting with ONE 1 90 ElbowVenting with Two 90 Elbows Venting with TWO 2 90 o ElbowsVenting with three 90 elbows Venting with Three 3 90 Elbows+ V 1 FT + H 1 FT Installing Vent Components Install Support Brackets To Install the Heat ShieldContinue Adding Vent Components 12 Hole and Vent Pipe Attic Firestop Vent TerminationVent Termination Minimum Clearances Proper Positioning Positioning, Leveling, Securing the FireplaceLeveling and Securing of a Fireplace Intermittent Pilot Ignition IPI System Installing the Optional Heat-Zone KitVice Must be Wired Directly to the FIRE- Place Junction BOX Gas Control SystemsGas Pressure Requirements Gas Supply LinePressure Natural Gas Propane Intermittent Pilot Ignition IPI Wiring Diagram Wiring the Fireplace Sealant Material Hearth Extensions FinishingInstalling Trim, Logs, and Ember Material Air Shutter Setting Double-check for faulty componentsBefore Lighting the Fireplace Important Turn OFF the GAS Before Servicing Your Fireplace After the InstallationFireplace Maintenance Lighting the Fireplace