Desa (V)CB36N(E), (V)CB36P(E) operation manual Models, VCB36NE and VCB36PE

Page 1

VENTED GAS FIREPLACE

INSTALLATION AND OWNER’S OPERATION MANUAL

4" B-VENT DECORATIVE GAS FIREPLACES

MODELS

(V)CB36N(E) and (V)CB36P(E)

WARNING: If the information in this manual is not fol- lowed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediatelycallyourgassupplierfromaneighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a quali- fied installer, service agency or the gas supplier.

INSTALLER: Leave this manual with the appliance

CONSUMER: Retain this manual for future reference.

For more information, visit www.desatech.com

Image 1
Contents VCB36NE and VCB36PE ModelsTable of Contents Safety information Local Codes Product IdentificationPre-Installation Preparation Product FeaturesLocation and space requirements Clearances Packaging and RemovalFraming and Finishing However, 0 clearance is also Mantel ClearancesVenting Installation Installation PrecautionsVenting Installation Electrical Supply Connection Checking for Proper VentingHigh Altitude Installation Installing Optional ControlsInstalling Optional Wall Mount Switch GWMS2 Installing Remote ReceiverInstalling and Activating the Remote Receiver Installing Optional ControlsWiring Diagrams Millivolt Wiring DiagramInstalling Gas Piping to Fireplace Location Fireplace InstallationInstallation Items Needed Check GAS TypeChecking GAS Connections Connecting Fireplace to GAS SupplyNatural From Louver Panels and Glass Door Pressure Testing Fireplace Gas ConnectionsTest Pressures Equal To or Less Than Psig 3.5 kPa Removing/Replacing Glass Door Spring Clips Removing Louver PanelsGlass Panel Frame Rail Applying Ember Material Installing Logs and Glowing EmbersOperating Fireplace Manual Ignition System For your safety Read before lightingLighting Instructions To Turn OFF GAS To ApplianceOptional Wireless Remote Operation Manual Lighting ProcedureElectronic Ignition System Lighting Instructions Optional Hand-Held Optional GWMS2 ON/OFF Wall Mounted SwitchOn/Off Series Model HRC100 Air Adjustment Setting Pilot AssemblyInspecting Burners Burner Flame PatternsGlass Door Cleaning MaintenancePilot and Burners Logs SpecificationsVenting System VCB36NEObserved Problem Possible Cause Remedy TroubleshootingLong enough See Lighting Instructions Observed Problem Possible Cause RemedyNo gas supply, or shutoff Statement above TroubleshootingIllustrated Parts Breakdown Parts List Illustrated Parts Breakdown Instructions Service Hints Replacement PartsTechnical Services AccessoriesWall Mounted ON/OFF Switch Remote Control KIT WRC SeriesGWMS2 Not Shown Keep this Warranty Warranty InformationLimited Warranty Vent Fireplace

(V)CB36P(E), (V)CB36N(E) specifications

The Desa (V)CB36N(E) and (V)CB36P(E) represent a significant advancement in heating technology, offering efficient and reliable heating solutions for diverse residential needs. Both models showcase an amalgamation of modern design, energy efficiency, and user-friendly features, making them ideal for contemporary living spaces.

One of the standout features of the Desa (V)CB36N(E) and (V)CB36P(E) is their exceptional heating capacity. Designed to deliver a consistent and comfortable temperature, these units can effectively heat areas of various sizes, ensuring that even larger living rooms or open spaces maintain a cozy ambiance. The (V)CB36N(E) is particularly noted for its natural gas compatibility, while the (V)CB36P(E) offers flexibility with propane options, catering to varying user preferences and available fuel sources.

Both models are equipped with advanced technologies that enhance their performance and efficiency. The use of high-efficiency burners significantly boosts their output while minimizing fuel consumption. This strategic design not only prolongs the lifespan of the units but also contributes to reduced greenhouse gas emissions, aligning with the growing demand for environmentally friendly heating solutions.

In terms of safety, Desa places a strong emphasis on user protection. Each unit is equipped with a robust safety shut-off system that activates when certain operational parameters are not met, ensuring peace of mind for users. Additionally, the inclusion of a protective mesh screen on both models helps prevent accidental burns, particularly important in households with children or pets.

Aesthetically, the Desa (V)CB36N(E) and (V)CB36P(E) blend seamlessly into any interior décor. With customizable design options and finishes, users can select models that best fit their home’s theme, whether it be contemporary, rustic, or traditional. This flexibility helps homeowners enhance their living spaces while also reaping the functional benefits of these heating units.

Furthermore, the intuitive controls allow for effortless operation, making temperature adjustments quick and convenient. With remote control capabilities available in some models, users can manage their heating systems from the comfort of their seating areas.

In conclusion, the Desa (V)CB36N(E) and (V)CB36P(E) offer a perfect combination of performance, safety, and style. With their innovative technologies and user-friendly features, these heating solutions stand out in the market as reliable choices for those seeking efficient home heating options.