Desa (V)CB36P(E) Louver Panels and Glass Door, Test Pressures Equal To or Less Than Psig 3.5 kPa

Page 16

Fireplace Installation

Continued

Test Pressures Equal To or Less Than

1/2 PSIG (3.5 kPa)

1. Close equipment shutoff valve (see Figure 25).

2. Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas fireplace or opening main gas valve located on or near gas meter for natural gas fireplace or using compressed air.

3. Check all joints from propane/LP supply tank or gas meter to equipment shutoff valve (see Figure 26, for propane/LP or Figure 27, for natural gas). Apply noncorrosive leak detec- tion fluid to all joints. Bubbles forming show a leak. Correct all leaks at once.

Equipment

Open

Shutoff Valve

Pressure Testing Fireplace Gas

Connections

1. Open equipment shutoff valve (see Figure 25).

2. Open propane/LP supply tank valve for pro- pane/LP fireplace or main gas valve located on or near gas meter for natural gas fireplace.

3. Make sure control knob of fireplace is in the OFF position.

4. Check all joints from equipment shutoff valve to gas valve (see Figure 26, for propane/LP or Figure 27, for natural gas). Apply non- corrosive leak detection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once.

5. Light fireplace (see Operating Fireplace, page

19). Check all other internal joints for leaks.

6. Turn off fireplace (see To Turn Off Gas to Appliance, page 19 or 20 depending on your model).

Closed

Figure 25 - Equipment Shutoff Valve

Louver Panels and Glass Door

CAUTION: Do not operate this fireplace with a broken glass

Propane/LP Supply Tank

Equipment Shutoff Valve

Gas Valve

door panel or without the glass door panel securely in place. For replacement part informa- tion see Replacement Parts, page 34.

CAUTION: Wear gloves and safety glasses while handling or removing broken glass. Do not remove if glass is hot. Keep

Figure 26 - Checking Gas Joints for

Propane/LP Gas Fireplace

Equipment

Shutoff

Valve

Gas

Meter

Gas Valve

Figure 27 - Checking Gas Joints for

Natural Gas Fireplace

children and pets away from glass.

WARNING: If fireplace has been running, turn off and un- plug fireplace. Let cool before re- moving glass door or louvers.

16

www.desatech.com

117437-01B

Image 16
Contents Models VCB36NE and VCB36PETable of Contents Safety information Product Identification Local CodesPre-Installation Preparation Product FeaturesLocation and space requirements Clearances Packaging and RemovalFraming and Finishing Mantel Clearances However, 0 clearance is alsoInstallation Precautions Venting InstallationVenting Installation Checking for Proper Venting Electrical Supply ConnectionInstalling Optional Controls High Altitude InstallationInstalling Optional Wall Mount Switch GWMS2 Installing Remote ReceiverInstalling Optional Controls Installing and Activating the Remote ReceiverMillivolt Wiring Diagram Wiring DiagramsFireplace Installation Installing Gas Piping to Fireplace LocationInstallation Items Needed Check GAS TypeChecking GAS Connections Connecting Fireplace to GAS SupplyNatural From Louver Panels and Glass Door Pressure Testing Fireplace Gas ConnectionsTest Pressures Equal To or Less Than Psig 3.5 kPa Removing/Replacing Glass Door Spring Clips Removing Louver PanelsGlass Panel Frame Rail Installing Logs and Glowing Embers Applying Ember MaterialManual Ignition System For your safety Read before lighting Operating FireplaceLighting Instructions To Turn OFF GAS To ApplianceOptional Wireless Remote Operation Manual Lighting ProcedureElectronic Ignition System Lighting Instructions Optional Hand-Held Optional GWMS2 ON/OFF Wall Mounted SwitchOn/Off Series Model HRC100 Pilot Assembly Air Adjustment SettingInspecting Burners Burner Flame PatternsGlass Door Cleaning MaintenancePilot and Burners Specifications LogsVenting System VCB36NETroubleshooting Observed Problem Possible Cause RemedyLong enough Observed Problem Possible Cause Remedy See Lighting InstructionsNo gas supply, or shutoff Troubleshooting Statement aboveIllustrated Parts Breakdown Parts List Illustrated Parts Breakdown Instructions Replacement Parts Service HintsTechnical Services AccessoriesWall Mounted ON/OFF Switch Remote Control KIT WRC SeriesGWMS2 Not Shown Keep this Warranty Warranty InformationLimited Warranty Vent Fireplace

(V)CB36P(E), (V)CB36N(E) specifications

The Desa (V)CB36N(E) and (V)CB36P(E) represent a significant advancement in heating technology, offering efficient and reliable heating solutions for diverse residential needs. Both models showcase an amalgamation of modern design, energy efficiency, and user-friendly features, making them ideal for contemporary living spaces.

One of the standout features of the Desa (V)CB36N(E) and (V)CB36P(E) is their exceptional heating capacity. Designed to deliver a consistent and comfortable temperature, these units can effectively heat areas of various sizes, ensuring that even larger living rooms or open spaces maintain a cozy ambiance. The (V)CB36N(E) is particularly noted for its natural gas compatibility, while the (V)CB36P(E) offers flexibility with propane options, catering to varying user preferences and available fuel sources.

Both models are equipped with advanced technologies that enhance their performance and efficiency. The use of high-efficiency burners significantly boosts their output while minimizing fuel consumption. This strategic design not only prolongs the lifespan of the units but also contributes to reduced greenhouse gas emissions, aligning with the growing demand for environmentally friendly heating solutions.

In terms of safety, Desa places a strong emphasis on user protection. Each unit is equipped with a robust safety shut-off system that activates when certain operational parameters are not met, ensuring peace of mind for users. Additionally, the inclusion of a protective mesh screen on both models helps prevent accidental burns, particularly important in households with children or pets.

Aesthetically, the Desa (V)CB36N(E) and (V)CB36P(E) blend seamlessly into any interior décor. With customizable design options and finishes, users can select models that best fit their home’s theme, whether it be contemporary, rustic, or traditional. This flexibility helps homeowners enhance their living spaces while also reaping the functional benefits of these heating units.

Furthermore, the intuitive controls allow for effortless operation, making temperature adjustments quick and convenient. With remote control capabilities available in some models, users can manage their heating systems from the comfort of their seating areas.

In conclusion, the Desa (V)CB36N(E) and (V)CB36P(E) offer a perfect combination of performance, safety, and style. With their innovative technologies and user-friendly features, these heating solutions stand out in the market as reliable choices for those seeking efficient home heating options.