Operating Fireplace

Continued

optional Hand-Held

REMOTE OPERATION

Note: All remote control accessories must be purchased separately (see Accessories, page 34). Follow instructions included with the remote control.

NOTICE: You must light the pilot before using the hand-held re- mote control unit. See Lighting Instructions, page 20.

After lighting, let pilot flame burn for about one minute. Turn control knob to ON position. Adjust flame adjustment knob anywhere be- tween HI and LO. Slide the selector switch to the REMOTE position (see Figure 36). Note: The burner may light if hand-held remote was on when selector switch was last turned off. You can now turn the burner on and off with the hand-held remote control unit.

IMPORTANT: Do not leave the selector switch in the REMOTE or ON position when the pilot is not lit. This will drain the battery.

To Unlock press both buttons together on hand-held remote control until the light stops flashing. The hand-held remote is now unlocked.

Indicator

LightControl

Button

Figure 37 - On/Off Hand-Held Remote

Control Unit HRC100

OPTIONAL GWMS2

ON/OFF WALL

MOUNTED SWITCH

WARNING: Do not connect the appliance gas controls to a 120 VAC power source. Damage

Blower Control Knob (Optional Accessory)

OFF ON

REMOTE

OFF

ON

Variable Control Knob

N

 

 

O

 

L

 

 

 

 

T

 

O

I

O

 

O

H

L

 

 

I

F

 

 

P F

 

or injury may occur.

Light the fireplace as instructed in Lighting Instructions on page 20 . If using an HRC re- mote with a wall switch, set the remote selector switch to the ON position (see Figure 36). The wall switch may now be used to turn the burner flame ON and OFF.

Gas Control Knob

Selector Switch in in ON Position

Remote Position

Figure 36 - Setting the Selector Switch,

Gas Control Knob and Variable Control

Knob for Remote Operation

On/Off Series Model HRC100

Hold the control button on the hand-held remote until burner turns on. Hold the con- trol button again until burner turns off (see Figure 37).

To Lock press both buttons on hand-held remote control until light stops flashing. Hand- held remote control is now locked. If the fire is on it will be turned off automatically. In the locked state, the light will not light up when any button is pressed.

To turn the fireplace off, turn the wall switch and/or remote selector switch to the OFF posi- tion and turn the gas control knob back to PILOT. The pilot will remain lit.

IMPORTANT: To turn the pilot off, turn the gas control knob on the heater to the OFF position.

117437-01B

www.desatech.com

21

Image 21
Contents VCB36NE and VCB36PE ModelsTable of Contents Safety information Local Codes Product IdentificationProduct Features Pre-Installation PreparationLocation and space requirements Packaging and Removal ClearancesFraming and Finishing However, 0 clearance is also Mantel ClearancesVenting Installation Installation PrecautionsVenting Installation Electrical Supply Connection Checking for Proper VentingHigh Altitude Installation Installing Optional ControlsInstalling Optional Wall Mount Switch GWMS2 Installing Remote ReceiverInstalling and Activating the Remote Receiver Installing Optional ControlsWiring Diagrams Millivolt Wiring DiagramInstalling Gas Piping to Fireplace Location Fireplace InstallationInstallation Items Needed Check GAS TypeConnecting Fireplace to GAS Supply Checking GAS ConnectionsNatural From Pressure Testing Fireplace Gas Connections Louver Panels and Glass DoorTest Pressures Equal To or Less Than Psig 3.5 kPa Removing Louver Panels Removing/Replacing Glass Door Spring ClipsGlass Panel Frame Rail Applying Ember Material Installing Logs and Glowing EmbersOperating Fireplace Manual Ignition System For your safety Read before lightingLighting Instructions To Turn OFF GAS To ApplianceManual Lighting Procedure Optional Wireless Remote OperationElectronic Ignition System Lighting Instructions Optional GWMS2 ON/OFF Wall Mounted Switch Optional Hand-HeldOn/Off Series Model HRC100 Air Adjustment Setting Pilot AssemblyInspecting Burners Burner Flame PatternsCleaning Maintenance Glass DoorPilot and Burners Logs SpecificationsVenting System VCB36NEObserved Problem Possible Cause Remedy TroubleshootingLong enough See Lighting Instructions Observed Problem Possible Cause RemedyNo gas supply, or shutoff Statement above TroubleshootingIllustrated Parts Breakdown Parts List Illustrated Parts Breakdown Instructions Service Hints Replacement PartsTechnical Services AccessoriesRemote Control KIT WRC Series Wall Mounted ON/OFF SwitchGWMS2 Not Shown Warranty Information Keep this WarrantyLimited Warranty Vent Fireplace

(V)CB36P(E), (V)CB36N(E) specifications

The Desa (V)CB36N(E) and (V)CB36P(E) represent a significant advancement in heating technology, offering efficient and reliable heating solutions for diverse residential needs. Both models showcase an amalgamation of modern design, energy efficiency, and user-friendly features, making them ideal for contemporary living spaces.

One of the standout features of the Desa (V)CB36N(E) and (V)CB36P(E) is their exceptional heating capacity. Designed to deliver a consistent and comfortable temperature, these units can effectively heat areas of various sizes, ensuring that even larger living rooms or open spaces maintain a cozy ambiance. The (V)CB36N(E) is particularly noted for its natural gas compatibility, while the (V)CB36P(E) offers flexibility with propane options, catering to varying user preferences and available fuel sources.

Both models are equipped with advanced technologies that enhance their performance and efficiency. The use of high-efficiency burners significantly boosts their output while minimizing fuel consumption. This strategic design not only prolongs the lifespan of the units but also contributes to reduced greenhouse gas emissions, aligning with the growing demand for environmentally friendly heating solutions.

In terms of safety, Desa places a strong emphasis on user protection. Each unit is equipped with a robust safety shut-off system that activates when certain operational parameters are not met, ensuring peace of mind for users. Additionally, the inclusion of a protective mesh screen on both models helps prevent accidental burns, particularly important in households with children or pets.

Aesthetically, the Desa (V)CB36N(E) and (V)CB36P(E) blend seamlessly into any interior décor. With customizable design options and finishes, users can select models that best fit their home’s theme, whether it be contemporary, rustic, or traditional. This flexibility helps homeowners enhance their living spaces while also reaping the functional benefits of these heating units.

Furthermore, the intuitive controls allow for effortless operation, making temperature adjustments quick and convenient. With remote control capabilities available in some models, users can manage their heating systems from the comfort of their seating areas.

In conclusion, the Desa (V)CB36N(E) and (V)CB36P(E) offer a perfect combination of performance, safety, and style. With their innovative technologies and user-friendly features, these heating solutions stand out in the market as reliable choices for those seeking efficient home heating options.