Desa (V)CB36N(E), (V)CB36P(E) Installing Optional Controls, High Altitude Installation

Page 11

Venting Installation

Continued

9.Strip back outer Romex to about 4" and con- nect black, white and green wires accordingly using 3 wire nut connectors.

10.Tuck tailing wires into junction box and replace junction box cover using 2 remaining screws.

11.Tighten adjustment on universal strain bush- ing to secure Romex sheathing and complete supply connection.

WARNING: This appliance, when installed must be electri- cally grounded in accordance with local code or in the ab- sence of local code, with the current National Electric Code, ANSI/NFPA 70, or the Canadian Electric Code, CSA C22.1.

HIGH ALTITUDE INSTALLATION

Your DESA direct-vent fireplace has been tested and approved in the USA for elevations from 0-2,000 feet (610 m) and in Canada at elevations from 0-4,500 feet (1,372 m).

When installing a non-high altitude fireplace at an elevation above 2,000 feet (610 m) (in the USA), you may need to decrease the input rating by changing the existing burner orifice to a smaller size. Reduce input 4% for each 1,000 feet (305 m) above sea level. Check with your local gas com- pany for proper orifice size identification.

When installing this fireplace in Canada at an elevation above 4,500 feet (1,372 m), Check with local or provincial code authorities.

Consult your local gas company to help determine the proper orifice for your location.

For assistance with any high altitude installation contact DESA’s Customer Service Department at 1-866-672-6040.

Installing Optional

Controls

INSTALLING OPTIONAL WALL MOUNT SWITCH - GWMS2

1.Connect one terminal of 15 foot wire from wall switch to male connector on high limit harness. Connect remaining wire terminal to TH terminal on valve. Make sure that wire terminals are in positions on unit as pictured in Figure 14. If wires are not connected as shown switch will not work.

2.Route 15 foot wire through hole openings with bushings provided on either side of fireplace cabinet.

3.Connect one bare wire end to each of terminals of GWMS2 wall switch.

4.Install wall switch and cover in wall. IMPORTANT: Do not use any other wire than that provided with GWMS2 wall switch kit. Do not exceed 15 feet of distance from valve connection.

Using wire of higher gauge or turns or exceeding minimum distance will increase resistance at control valve causing unreliable performance of fireplace controls.

Remote Receiver

Wire Harness From

or Wall Switch to

High Limit Switch

Terminal Marked “TH”

 

Male Connector to Remote Receiver or Wall Switch

Figure 14 - Connecting Remote Receiver or Wall Switch to the Gas Control Valve

INSTALLING OPTIONAL WIRELESS HAND-HELD REMOTE CONTROL MODEL HRC100

Installing Remote Receiver

1. Open bottom louver and locate switch bracket on right side.

2. Locate battery clip mounted on back of receiver. Slide a 9-volt alkaline battery (not included) through clip.

3. Attach terminal wires to battery (see Fig- ure 15).

4. Connect one wire from receiver to male con- nector on high limit harness and one to “TH” on control valve (see Figure 14).

5. Locate two plastic mounting clips provided with kit.

Receiver

9-Volt Alkaline Battery

Terminal

Wires

Battery Clip

Figure 15 - Attaching Alkaline Battery to

Receiver

117437-01B

www.desatech.com

11

Image 11
Contents VCB36NE and VCB36PE ModelsTable of Contents Safety information Local Codes Product IdentificationLocation and space requirements Product FeaturesPre-Installation Preparation Framing and Finishing Packaging and RemovalClearances However, 0 clearance is also Mantel ClearancesVenting Installation Installation PrecautionsVenting Installation Electrical Supply Connection Checking for Proper VentingInstalling Remote Receiver Installing Optional ControlsHigh Altitude Installation Installing Optional Wall Mount Switch GWMS2Installing and Activating the Remote Receiver Installing Optional ControlsWiring Diagrams Millivolt Wiring DiagramCheck GAS Type Fireplace InstallationInstalling Gas Piping to Fireplace Location Installation Items NeededNatural From Connecting Fireplace to GAS SupplyChecking GAS Connections Test Pressures Equal To or Less Than Psig 3.5 kPa Pressure Testing Fireplace Gas ConnectionsLouver Panels and Glass Door Glass Panel Frame Rail Removing Louver PanelsRemoving/Replacing Glass Door Spring Clips Applying Ember Material Installing Logs and Glowing EmbersTo Turn OFF GAS To Appliance Manual Ignition System For your safety Read before lightingOperating Fireplace Lighting InstructionsElectronic Ignition System Lighting Instructions Manual Lighting ProcedureOptional Wireless Remote Operation On/Off Series Model HRC100 Optional GWMS2 ON/OFF Wall Mounted SwitchOptional Hand-Held Burner Flame Patterns Pilot AssemblyAir Adjustment Setting Inspecting BurnersPilot and Burners Cleaning MaintenanceGlass Door VCB36NE SpecificationsLogs Venting SystemObserved Problem Possible Cause Remedy TroubleshootingLong enough See Lighting Instructions Observed Problem Possible Cause RemedyNo gas supply, or shutoff Statement above TroubleshootingIllustrated Parts Breakdown Parts List Illustrated Parts Breakdown Instructions Accessories Replacement PartsService Hints Technical ServicesGWMS2 Not Shown Remote Control KIT WRC SeriesWall Mounted ON/OFF Switch Limited Warranty Vent Fireplace Warranty InformationKeep this Warranty

(V)CB36P(E), (V)CB36N(E) specifications

The Desa (V)CB36N(E) and (V)CB36P(E) represent a significant advancement in heating technology, offering efficient and reliable heating solutions for diverse residential needs. Both models showcase an amalgamation of modern design, energy efficiency, and user-friendly features, making them ideal for contemporary living spaces.

One of the standout features of the Desa (V)CB36N(E) and (V)CB36P(E) is their exceptional heating capacity. Designed to deliver a consistent and comfortable temperature, these units can effectively heat areas of various sizes, ensuring that even larger living rooms or open spaces maintain a cozy ambiance. The (V)CB36N(E) is particularly noted for its natural gas compatibility, while the (V)CB36P(E) offers flexibility with propane options, catering to varying user preferences and available fuel sources.

Both models are equipped with advanced technologies that enhance their performance and efficiency. The use of high-efficiency burners significantly boosts their output while minimizing fuel consumption. This strategic design not only prolongs the lifespan of the units but also contributes to reduced greenhouse gas emissions, aligning with the growing demand for environmentally friendly heating solutions.

In terms of safety, Desa places a strong emphasis on user protection. Each unit is equipped with a robust safety shut-off system that activates when certain operational parameters are not met, ensuring peace of mind for users. Additionally, the inclusion of a protective mesh screen on both models helps prevent accidental burns, particularly important in households with children or pets.

Aesthetically, the Desa (V)CB36N(E) and (V)CB36P(E) blend seamlessly into any interior décor. With customizable design options and finishes, users can select models that best fit their home’s theme, whether it be contemporary, rustic, or traditional. This flexibility helps homeowners enhance their living spaces while also reaping the functional benefits of these heating units.

Furthermore, the intuitive controls allow for effortless operation, making temperature adjustments quick and convenient. With remote control capabilities available in some models, users can manage their heating systems from the comfort of their seating areas.

In conclusion, the Desa (V)CB36N(E) and (V)CB36P(E) offer a perfect combination of performance, safety, and style. With their innovative technologies and user-friendly features, these heating solutions stand out in the market as reliable choices for those seeking efficient home heating options.