Desa (V)CB36P(E), (V)CB36N(E) Replacement Parts, Service Hints, Technical Services, Accessories

Page 34

Replacement Parts

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

Parts Under Warranty

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA’s Technical Service Department at 1-866-672-6040. When calling DESA have ready

your name and address

model and serial numbers of your heater

how heater was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the part to the factory.

Parts Not Under Warranty

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA at 1-866-672-6040 for referral information. When calling DESA, have ready

model number of your heater

the replacement part number

Service Hints

When Gas Pressure Is Too Low

• pilot will not stay lit

• burners will have delayed ignition

• heater will not produce specified heat

• for propane/LP units, propane/LP gas supply may be low

You may feel your gas pressure is too low. If so, contact your local natural or propane/LP gas supplier.

Technical Services

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA’s Technical Service Department at 1-866-672-6040. When calling please have your model and serial numbers of your heater ready.

You can also visit DESA’s technical services web site at www.desatech.com.

Accessories

NOTE: All accessories may not be available for all fireplace models.

Purchase these fireplace accessories from your local retailer. If they can not supply these acces- sories, call DESA’s Sales Department at 1-866- 672-6040, for information. You can also write to the address listed on the back of this manual

FLEXIBLE GAS LINE CONNECTOR

GA5081 (Not Shown)

For all models.

PROPANE/NATURAL GAS

CONVERSION KIT (Not Shown)

PCBM-36C- Propane/LP Gas Millivolt Models

NCBM-36C- Natural Gas Millivolt Models

PCBE-36C- Propane/LP Gas Electronic Models

NCBE-36C- Natural Gas Electronic Models

Rolled LOUVER TRIM KITS

LTC36B - Brushed Brass

LTC36P - Platinum

Face mantels

FM36AP - 36" primed, Traditional FM36AU - 36" unfinished, Traditional FM36AO - 36" oak stained, Traditional FM36BP - 36" primed, Federal FM36BU - 36" unfinished, Federal FM36BO - 36" oak stained, Federal FM36CP - 36" primed, Classic FM36CU - 36" unfinished, Classic FM36CO - 36" oak stained, Classic FM42BP - 42" primed, Federal FM42BU - 42" unfinished, Federal FM42BO - 42" oak stained, Federal

Face mantels frame your fireplace and can be in- stalled around wood, gas or electric fireplaces.

34

www.desatech.com

117437-01B

Image 34
Contents Models VCB36NE and VCB36PETable of Contents Safety information Product Identification Local CodesPre-Installation Preparation Product FeaturesLocation and space requirements Clearances Packaging and RemovalFraming and Finishing Mantel Clearances However, 0 clearance is alsoInstallation Precautions Venting InstallationVenting Installation Checking for Proper Venting Electrical Supply ConnectionInstalling Optional Wall Mount Switch GWMS2 Installing Optional ControlsHigh Altitude Installation Installing Remote ReceiverInstalling Optional Controls Installing and Activating the Remote ReceiverMillivolt Wiring Diagram Wiring DiagramsInstallation Items Needed Fireplace InstallationInstalling Gas Piping to Fireplace Location Check GAS TypeChecking GAS Connections Connecting Fireplace to GAS SupplyNatural From Louver Panels and Glass Door Pressure Testing Fireplace Gas ConnectionsTest Pressures Equal To or Less Than Psig 3.5 kPa Removing/Replacing Glass Door Spring Clips Removing Louver PanelsGlass Panel Frame Rail Installing Logs and Glowing Embers Applying Ember MaterialLighting Instructions Manual Ignition System For your safety Read before lightingOperating Fireplace To Turn OFF GAS To ApplianceOptional Wireless Remote Operation Manual Lighting ProcedureElectronic Ignition System Lighting Instructions Optional Hand-Held Optional GWMS2 ON/OFF Wall Mounted SwitchOn/Off Series Model HRC100 Inspecting Burners Pilot AssemblyAir Adjustment Setting Burner Flame PatternsGlass Door Cleaning MaintenancePilot and Burners Venting System SpecificationsLogs VCB36NETroubleshooting Observed Problem Possible Cause RemedyLong enough Observed Problem Possible Cause Remedy See Lighting InstructionsNo gas supply, or shutoff Troubleshooting Statement aboveIllustrated Parts Breakdown Parts List Illustrated Parts Breakdown Instructions Technical Services Replacement PartsService Hints AccessoriesWall Mounted ON/OFF Switch Remote Control KIT WRC SeriesGWMS2 Not Shown Keep this Warranty Warranty InformationLimited Warranty Vent Fireplace

(V)CB36P(E), (V)CB36N(E) specifications

The Desa (V)CB36N(E) and (V)CB36P(E) represent a significant advancement in heating technology, offering efficient and reliable heating solutions for diverse residential needs. Both models showcase an amalgamation of modern design, energy efficiency, and user-friendly features, making them ideal for contemporary living spaces.

One of the standout features of the Desa (V)CB36N(E) and (V)CB36P(E) is their exceptional heating capacity. Designed to deliver a consistent and comfortable temperature, these units can effectively heat areas of various sizes, ensuring that even larger living rooms or open spaces maintain a cozy ambiance. The (V)CB36N(E) is particularly noted for its natural gas compatibility, while the (V)CB36P(E) offers flexibility with propane options, catering to varying user preferences and available fuel sources.

Both models are equipped with advanced technologies that enhance their performance and efficiency. The use of high-efficiency burners significantly boosts their output while minimizing fuel consumption. This strategic design not only prolongs the lifespan of the units but also contributes to reduced greenhouse gas emissions, aligning with the growing demand for environmentally friendly heating solutions.

In terms of safety, Desa places a strong emphasis on user protection. Each unit is equipped with a robust safety shut-off system that activates when certain operational parameters are not met, ensuring peace of mind for users. Additionally, the inclusion of a protective mesh screen on both models helps prevent accidental burns, particularly important in households with children or pets.

Aesthetically, the Desa (V)CB36N(E) and (V)CB36P(E) blend seamlessly into any interior décor. With customizable design options and finishes, users can select models that best fit their home’s theme, whether it be contemporary, rustic, or traditional. This flexibility helps homeowners enhance their living spaces while also reaping the functional benefits of these heating units.

Furthermore, the intuitive controls allow for effortless operation, making temperature adjustments quick and convenient. With remote control capabilities available in some models, users can manage their heating systems from the comfort of their seating areas.

In conclusion, the Desa (V)CB36N(E) and (V)CB36P(E) offer a perfect combination of performance, safety, and style. With their innovative technologies and user-friendly features, these heating solutions stand out in the market as reliable choices for those seeking efficient home heating options.