Desa FPVF33PRA Conventional Fireplace Installation, Placing Hearth Base Accessory Against Wall

Page 10

Installation

Continued

Conventional Fireplace Installation

Conventional installation of this fireplace involves installing fireplace along with the corner, face or cabinet mantel with hearth base accessories against a wall in your home. Follow the instructions below to install the fireplace in this manner.

Note: The instructions in this section show instal- lation using the cabinet mantel and hearth base accessories. The hearth base accessory shown is optional for this installation. You can install fireplace and cabinet mantel directly on the floor. The corner mantel accessory (VYGF models only) can only be paired with the corner hearth base. If mounting fireplace and cabinet or corner mantel to the floor, an optional G3005 Series Slim Base kit may be installed.

1.Assemble cabinet mantel, hearth base and trim accessories. Assembly instructions are included with each accessory.

2.When installing blower, install a properly grounded, 120 volt three-prong electrical out- let at fireplace location if an outlet is not there. If possible, locate outlet so cabinet mantel will cover it when installed (see Figure 9).

3.Install gas piping to fireplace location. This in- stallation includes an approved flexible gas line (if allowed by local codes) after the equipment shutoff valve. The flexible gas line must be the last item installed on the gas piping. See Install- ing Gas Piping to Fireplace Location, page 13.

4.Place hearth base accessory against wall at installation location. Cut an access hole in hearth top to run flexible gas line to fireplace (see Figure 9). Make sure to locate access hole so cabinet mantel will cover it when installed. Note: You can secure base to floor using wood screws. Countersink screw heads and putty over.

5.Route flexible gas line through access hole in hearth base.

6.Center cabinet mantel on hearth base (see Figure 10). Make sure mantel is flush against wall.

7.Break off nailing flanges (see Figure 11) with hammer or pliers.

8.Place cardboard or other protective material on top of hearth base. Carefully set fireplace on protective material, with back of fireplace inside mantel opening.

9.Attach flexible gas line from fireplace gas regulator to gas supply. See Connecting Fireplace to Gas Supply, page 14.

 

Rigid

Electrical

Gas

Hearth

Outlet

Line

Gas

Base

 

Access

Line

 

 

 

Hole

 

 

 

Figure 9 - Placing Hearth Base

Accessory Against Wall

Cabinet

Mantel

Figure 10 - Installing Cabinet Mantel

Nailing

Flanges

Figure 11 - Location of Nailing Flanges

Figure 12 - Inserting Fireplace Into

Cabinet Mantel

10

www.desatech.com

113109-01C

Image 10
Contents Remote-Ready Gas Fireplace Systems VYGF33PRC, VYGF33NRC, FPVF33PRA millivoltFPVF33NRA Millivolt Patent PendingTable of Contents Safety InformationSafety Information Troubleshooting, Product IdentificationUnpacking Product FeaturesLocal Codes Air For Combustion VentilationUnusually Tight Construction Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Confined and Unconfined SpaceVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Check GAS Type InstallationInstalling Hood Electrical HookupInstallation Clearances Repeat steps 1 through 6 for other sideConventional Fireplace Installation Placing Hearth Base Accessory Against WallChecking Gas Connections, Models VYGF33PRB and VYGF33NRBConnecting Duplex Outlet Models FPVF33PRA and FPVF33NRAMantel Clearances for Built-In Installation Installing Gas Piping to Fireplace LocationInstallation Items Needed Natural Gas From Gas Meter 5 W.C.** to Connecting Fireplace to GAS SupplyAccessories, Propane/LPChecking Gas Connections Checking GAS ConnectionsNatural Gas Pressure Testing Fireplace Gas Connections Test Pressures Equal To or Less Than Psig 3.5 kPaInstalling Logs Vygf Models OnlyInstalling Remote Receiver Unit Fpvf Models OnlyInstalling 9-Volt Battery in Receiver Installing 9-Volt BatteriesFor Your Safety Read Before Lighting Installing 9-Volt Battery in Hand-Held Remote Control UnitOperating Fireplace Lighting InstructionsOptional Hand-Held  MANUAL Lighting ProcedureTo Turn OFF GAS To Appliance Remote OperationThermostat Series Model HRC200 Optional Blower OperationBurner Flame Pattern Inspecting BurnerPilot Flame Pattern Burner Primary AIR HolesBurner Injector Holder and Pilot Air Inlet Hole Cleaning MaintenanceLogs Observed Problem Possible Cause Remedy TroubleshootingIng and Maintenance, Maintenance, Diagram,See Cleaning and Mainte On windows Tilation air See Checking Gas Connec Gas leak. See WarningStalling Logs, Replacement Parts Wiring DiagramSpecifications Technical ServiceIllustrated Parts Breakdown Models VYGF33PRC and VYGF33NRC ShownParts List Models FPVF33PRA and FPVF33NRA KEY Description Firebox Models VYGF33PRC and VYGF33NRC Parts List Firebox Models FPVF33PRA and FPVF33NRA 101357-01 Accessories Wall Cabinet Mantel and Base Accessory with FireplacePerimeter Trim Not Shown Keep this Warranty Warranty InformationLimited Warranty VENT-FREE GAS Fireplace