Desa VYGF33NRC, FPVF33PRA Installation Clearances, Repeat steps 1 through 6 for other side

Page 9

Installation

Continued

Assembling and attaching OPTIONAL perimeter trim (Included with Mantel Accessory)

IMPORTANT: If you are recessing the firebox in a wall, do not attach perimeter trim at this time. See Built-In Fireplace Installation, page 11.

Note: The instructions below show assembling and attaching perimeter trim to fireplace.

1.Remove packaging from three pieces of pe- rimeter trim.

2.Locate four perimeter screws, two adjusting plates with set screws and two shims in the hardware packet.

3.Align shim under adjusting plate as shown in

Figure 6.

4.Slide one end of adjusting plate/shim in slot on mitered edge of top perimeter trim (see Figure 6).

5.Slide other end of adjusting plate/shim in slot on mitered edge of side perimeter trim (see Figure 6).

6.While firmly holding edges of perimeter trim together, tighten both set screws on the adjust- ing plate with slotted screwdriver.

7.Repeat steps 1 through 6 for other side.

8.Tighten trim hanging screws (#10 x 6.25 shoulder) into holes in cabinets. Place the assembled trim onto fireplace cabinet. Align hanging notches on trim with hanging screws on side of fireplace (see Figure 7). Push trim firmly into place, sliding hanging notches over hanging screws.

Set Screws

 

Adjusting

Top

Side Trim

Plate

Trim

 

Shim

 

 

Mitered

Slot

Slot

Edge

 

 

Figure 6 - Assembling Perimeter Trim

Trim

Hanging

Screws

Hanging

Notches

on Trim

Assembled

Trim

Figure 7 - Attaching Perimeter Trim to

Fireplace

INSTALLATION CLEARANCES

WARNING: Maintain the minimum clearances. If you can, provide greater clearances from floor, ceiling and adjoining wall.

Carefully follow the instructions below. This will ensure safe installation.

Minimum Clearances For Side Combustible

Material, Side Wall and Ceiling

A. Clearances from the side of the fireplace cabinet to any combustible material and wall should follow diagram in Figure 8.

Example: The face of a mantel, bookshelf, etc. is made of combustible material and protrudes 3 1/2" from the wall. This combus- tible material must be 4" from the side of the fireplace opening (see Figure 8).

B. Clearances from the top of the fireplace opening to the ceiling should not be less than 42".

Minimum Clearance to Combustible Materials

Top: 42", Left and Right Sides: 16"

Bottom and Rear: 0"

Example

*

*Minimum 16" from Side Wall

Figure 8 - Minimum Clearance for

Combustible to Wall

113109-01Cwww.desatech.com

Image 9
Contents FPVF33NRA Millivolt VYGF33PRC, VYGF33NRC, FPVF33PRA millivoltRemote-Ready Gas Fireplace Systems Patent PendingSafety Information Table of ContentsSafety Information Product Identification Troubleshooting,Local Codes Product FeaturesUnpacking Air For Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installing Hood InstallationCheck GAS Type Electrical HookupRepeat steps 1 through 6 for other side Installation ClearancesPlacing Hearth Base Accessory Against Wall Conventional Fireplace InstallationModels VYGF33PRB and VYGF33NRB Checking Gas Connections,Models FPVF33PRA and FPVF33NRA Connecting Duplex OutletInstalling Gas Piping to Fireplace Location Mantel Clearances for Built-In InstallationInstallation Items Needed Accessories, Connecting Fireplace to GAS SupplyNatural Gas From Gas Meter 5 W.C.** to Propane/LPChecking GAS Connections Checking Gas ConnectionsNatural Gas Test Pressures Equal To or Less Than Psig 3.5 kPa Pressure Testing Fireplace Gas ConnectionsVygf Models Only Installing LogsFpvf Models Only Installing Remote Receiver UnitFor Your Safety Read Before Lighting Installing 9-Volt BatteriesInstalling 9-Volt Battery in Receiver Installing 9-Volt Battery in Hand-Held Remote Control UnitLighting Instructions Operating FireplaceTo Turn OFF GAS To Appliance  MANUAL Lighting ProcedureOptional Hand-Held Remote OperationOptional Blower Operation Thermostat Series Model HRC200Pilot Flame Pattern Inspecting BurnerBurner Flame Pattern Burner Primary AIR HolesCleaning Maintenance Burner Injector Holder and Pilot Air Inlet HoleLogs Troubleshooting Observed Problem Possible Cause RemedyIng and Maintenance, Diagram, Maintenance,See Cleaning and Mainte On windows Tilation air Gas leak. See Warning See Checking Gas ConnecStalling Logs, Specifications Wiring DiagramReplacement Parts Technical ServiceModels VYGF33PRC and VYGF33NRC Shown Illustrated Parts BreakdownParts List Models FPVF33PRA and FPVF33NRA KEY Description Firebox Models VYGF33PRC and VYGF33NRC Parts List Firebox Models FPVF33PRA and FPVF33NRA 101357-01 Accessories Accessory with Fireplace Wall Cabinet Mantel and BasePerimeter Trim Not Shown Warranty Information Keep this WarrantyLimited Warranty VENT-FREE GAS Fireplace