Desa VYGF33NRC Wall Cabinet Mantel and Base, Accessory with Fireplace, Perimeter Trim Not Shown

Page 39

Accessories

Continued

Corner CABINET Mantel with Base and perimeter trim (Not Shown)

C32AU - 32" Unfinished, Traditional Design

C32AOS - Light Oak Finish, Traditional

Design

C32HS - 32" Dark Oak Finish, Classic

Design

Ideal for space saving installations.

Wall CABINET MANTEL AND BASE

ACCESSORY WITH FIREPLACE

PERIMETER TRIM (Not Shown)

W32AU - 32" Unfinished, Traditional Design W32AOS - 32" Light Oak Finish, Traditional Design

CMA311W - 32" Painted White, Traditional Design with Dentil Molding CMA306FA - 32" Light Oak Finish, Traditional Design with Dentil Molding CMA312FB - 32" Dark Oak Finish, Classic Design

W32KCSA - 32" Cherry Finish, Neo- Classical Design

W32KPA - 32" Painted White, Neo- Classical Design

CMA305UA - 32" Unfinished, Georgian Design with Columns

GMC90FA - 32" Light Oak Finish, Georgian Design with Columns

W32DS - 32" Dark Oak Finish, Keystone Design

W32GOSA - 32" Dark Oak Finish, Mission Design

113109-01C

www.desatech.com

39

Image 39
Contents Patent Pending VYGF33PRC, VYGF33NRC, FPVF33PRA millivoltFPVF33NRA Millivolt Remote-Ready Gas Fireplace SystemsSafety Information Table of ContentsSafety Information Product Identification Troubleshooting,Air For Combustion Ventilation Product FeaturesLocal Codes UnpackingConfined and Unconfined Space Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Unusually Tight ConstructionVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Electrical Hookup InstallationInstalling Hood Check GAS TypeRepeat steps 1 through 6 for other side Installation ClearancesPlacing Hearth Base Accessory Against Wall Conventional Fireplace InstallationModels VYGF33PRB and VYGF33NRB Checking Gas Connections,Models FPVF33PRA and FPVF33NRA Connecting Duplex OutletInstalling Gas Piping to Fireplace Location Mantel Clearances for Built-In InstallationInstallation Items Needed Propane/LP Connecting Fireplace to GAS SupplyAccessories, Natural Gas From Gas Meter 5 W.C.** toChecking GAS Connections Checking Gas ConnectionsNatural Gas Test Pressures Equal To or Less Than Psig 3.5 kPa Pressure Testing Fireplace Gas ConnectionsVygf Models Only Installing LogsFpvf Models Only Installing Remote Receiver UnitInstalling 9-Volt Battery in Hand-Held Remote Control Unit Installing 9-Volt BatteriesFor Your Safety Read Before Lighting Installing 9-Volt Battery in ReceiverLighting Instructions Operating FireplaceRemote Operation  MANUAL Lighting ProcedureTo Turn OFF GAS To Appliance Optional Hand-HeldOptional Blower Operation Thermostat Series Model HRC200Burner Primary AIR Holes Inspecting BurnerPilot Flame Pattern Burner Flame PatternCleaning Maintenance Burner Injector Holder and Pilot Air Inlet HoleLogs Troubleshooting Observed Problem Possible Cause RemedyIng and Maintenance, Diagram, Maintenance,See Cleaning and Mainte On windows Tilation air Gas leak. See Warning See Checking Gas ConnecStalling Logs, Technical Service Wiring DiagramSpecifications Replacement PartsModels VYGF33PRC and VYGF33NRC Shown Illustrated Parts BreakdownParts List Models FPVF33PRA and FPVF33NRA KEY Description Firebox Models VYGF33PRC and VYGF33NRC Parts List Firebox Models FPVF33PRA and FPVF33NRA 101357-01 Accessories Accessory with Fireplace Wall Cabinet Mantel and BasePerimeter Trim Not Shown Warranty Information Keep this WarrantyLimited Warranty VENT-FREE GAS Fireplace