Desa FPVF33PRA, VYGF33NRC installation manual Diagram, Maintenance, See Cleaning and Mainte

Page 26

Troubleshooting

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

 

ODS/pilot lights but flame

1. Control knob not fully pressed in

1.

Press in control knob fully

goes out when control knob is

2. Control knob not pressed in

2.

After ODS/pilot lights, keep con-

released

3.

long enough

3.

trol knob pressed in 30 seconds

 

Equipment shutoff valve not

Fully open equipment shutoff

 

4.

fully open

4.

valve

 

Pilot flame not touching ther-

A) Contact local natural or

 

 

mocouple, which allows ther-

 

propane/LP gas company

 

 

mocouple to cool, causing

 

B) Clean ODS/pilot (see

 

 

pilot flame to go out. This

 

 

 

problem could be caused by

 

Cleaning and Maintenance,

 

 

one or both of the following:

 

page 24) or replace ODS/pilot

 

 

A) Low gas pressure

 

assembly

 

 

B) Dirty or partially clogged

 

 

 

 

5.

ODS/pilot

5.

Hand tighten until snug, then

 

Thermocouple connection

 

6.

loose at control valve

6.

tighten 1/4 turn more

 

Thermocouple damaged

Replace pilot assembly

 

7.

Control valve damaged

7.

Replace control valve

 

 

 

 

 

Burner does not light after

1. Inlet gas pressure is too low

1.

Contact local natural or pro-

ODS/pilot is lit

2.

Burner orifice(s) clogged

2.

pane/LP gas company

 

Clean burner(s) (see Cleaning

 

 

 

 

and Maintenance, page 24) or

 

3.

Thermopile leads disconnected

3.

replace burner orifice(s)

 

Reconnect leads (see Wiring

 

4.

or improperly connected

4.

Diagram, page 29)

 

Burner will not come on in

Replace battery in transmitter

 

 

remote position

 

and receiver

 

 

 

 

 

Delayed ignition of one or both

1. Manifold pressure is too low

1.

Contact local natural or pro-

burners

2.

Burner orifice(s) clogged

2.

pane/LP gas company

 

Clean burner(s) (see Cleaning

 

 

 

 

and Maintenance, page 24) or

 

 

 

 

replace burner orifice(s)

 

 

 

 

 

Burner backfiring during com-

1. Burner orifice is clogged or

1.

Clean burner (see Cleaning

bustion

 

damaged

 

and Maintenance, page 24)

 

2.

Damaged burner

2.

or replace burner orifice(s)

 

Replace damaged burner

 

3.

Gas regulator defective

3.

Replace gas regulator

 

 

 

 

 

Slight smoke or odor during

1. Not enough air

1.

Check burner for dirt and

initial operation

 

 

 

debris. If found, clean burner

 

 

 

 

(see Cleaning and Mainte-

 

2.

Gas regulator defective

2.

nance, page 24)

 

Replace gas control

 

3.

Residues from manufacturing

3.

Problem will stop after a few

 

 

processes and logs curing

 

hours of operation

26

www.desatech.com

113109-01C

Image 26
Contents Remote-Ready Gas Fireplace Systems VYGF33PRC, VYGF33NRC, FPVF33PRA millivoltFPVF33NRA Millivolt Patent PendingTable of Contents Safety InformationSafety Information Troubleshooting, Product IdentificationUnpacking Product FeaturesLocal Codes Air For Combustion VentilationUnusually Tight Construction Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Confined and Unconfined SpaceVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Check GAS Type InstallationInstalling Hood Electrical HookupInstallation Clearances Repeat steps 1 through 6 for other sideConventional Fireplace Installation Placing Hearth Base Accessory Against WallChecking Gas Connections, Models VYGF33PRB and VYGF33NRBConnecting Duplex Outlet Models FPVF33PRA and FPVF33NRAInstallation Items Needed Installing Gas Piping to Fireplace LocationMantel Clearances for Built-In Installation Natural Gas From Gas Meter 5 W.C.** to Connecting Fireplace to GAS SupplyAccessories, Propane/LPNatural Gas Checking GAS ConnectionsChecking Gas Connections Pressure Testing Fireplace Gas Connections Test Pressures Equal To or Less Than Psig 3.5 kPaInstalling Logs Vygf Models OnlyInstalling Remote Receiver Unit Fpvf Models OnlyInstalling 9-Volt Battery in Receiver Installing 9-Volt BatteriesFor Your Safety Read Before Lighting Installing 9-Volt Battery in Hand-Held Remote Control UnitOperating Fireplace Lighting InstructionsOptional Hand-Held  MANUAL Lighting ProcedureTo Turn OFF GAS To Appliance Remote OperationThermostat Series Model HRC200 Optional Blower OperationBurner Flame Pattern Inspecting BurnerPilot Flame Pattern Burner Primary AIR HolesLogs Cleaning MaintenanceBurner Injector Holder and Pilot Air Inlet Hole Ing and Maintenance, TroubleshootingObserved Problem Possible Cause Remedy See Cleaning and Mainte Diagram,Maintenance, On windows Tilation air Stalling Logs, Gas leak. See WarningSee Checking Gas Connec Replacement Parts Wiring DiagramSpecifications Technical ServiceIllustrated Parts Breakdown Models VYGF33PRC and VYGF33NRC ShownParts List Models FPVF33PRA and FPVF33NRA KEY Description Firebox Models VYGF33PRC and VYGF33NRC Parts List Firebox Models FPVF33PRA and FPVF33NRA 101357-01 Accessories Perimeter Trim Not Shown Accessory with FireplaceWall Cabinet Mantel and Base Limited Warranty VENT-FREE GAS Fireplace Warranty InformationKeep this Warranty