Desa VYGF33NRC, FPVF33PRA installation manual 101357-01

Page 37

PARTS LIST

Firebox Models FPVF33PRA AND FPVF33NRA

This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 29 of this manual.

KEY

 

 

NO. PART NO.

DESCRIPTION

QTY.

1

101357-01

2

**

3

**

4

**

5 098304-01

6 104239-01CK

7 101712-03

8

**

9

099230-02

10

**

11

**

12

**

13 101514-01

14 M11084-26

15 110466-01

16 101727-02

17 GA3555

18 M12461-2

19 098304-03

20 103706-01

Top Outer Casing

Outer Casing

Right Front Side

Left Front Side

Phillips Pan Head Screw, #10

Top Front Louver

Firebox Hood

Firebox Support

Shoulder Screw

Firebox Top

Outer Base

Firebox Wrapper

Cover

Hex Screw, #10

Bottom Louvered Door

Screen Assembly

Duplex Outlet Kit

Hex Screw

Screw

Duplex Receptacle Shield

1

1

1

1

9

1

1

2

4

1

1

1

1

45

1

1

1

1

2

1

PARTS AVAILABLE — NOT SHOWN

101386-02

Louvered Door Hinge

101784-01

Magnet Catch

102307-01

Strike Plate

103771-01

Strain Relief Fitting

** Not a field replaceable part.

2

2

2

1

113109-01C

www.desatech.com

37

Image 37
Contents FPVF33NRA Millivolt VYGF33PRC, VYGF33NRC, FPVF33PRA millivoltRemote-Ready Gas Fireplace Systems Patent PendingSafety Information Table of ContentsSafety Information Product Identification Troubleshooting,Local Codes Product FeaturesUnpacking Air For Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installing Hood InstallationCheck GAS Type Electrical HookupRepeat steps 1 through 6 for other side Installation ClearancesPlacing Hearth Base Accessory Against Wall Conventional Fireplace InstallationModels VYGF33PRB and VYGF33NRB Checking Gas Connections,Models FPVF33PRA and FPVF33NRA Connecting Duplex OutletMantel Clearances for Built-In Installation Installing Gas Piping to Fireplace LocationInstallation Items Needed Accessories, Connecting Fireplace to GAS SupplyNatural Gas From Gas Meter 5 W.C.** to Propane/LPChecking Gas Connections Checking GAS ConnectionsNatural Gas Test Pressures Equal To or Less Than Psig 3.5 kPa Pressure Testing Fireplace Gas ConnectionsVygf Models Only Installing LogsFpvf Models Only Installing Remote Receiver UnitFor Your Safety Read Before Lighting Installing 9-Volt BatteriesInstalling 9-Volt Battery in Receiver Installing 9-Volt Battery in Hand-Held Remote Control UnitLighting Instructions Operating FireplaceTo Turn OFF GAS To Appliance  MANUAL Lighting ProcedureOptional Hand-Held Remote OperationOptional Blower Operation Thermostat Series Model HRC200Pilot Flame Pattern Inspecting BurnerBurner Flame Pattern Burner Primary AIR HolesBurner Injector Holder and Pilot Air Inlet Hole Cleaning MaintenanceLogs Observed Problem Possible Cause Remedy TroubleshootingIng and Maintenance, Maintenance, Diagram,See Cleaning and Mainte On windows Tilation air See Checking Gas Connec Gas leak. See WarningStalling Logs, Specifications Wiring DiagramReplacement Parts Technical ServiceModels VYGF33PRC and VYGF33NRC Shown Illustrated Parts BreakdownParts List Models FPVF33PRA and FPVF33NRA KEY Description Firebox Models VYGF33PRC and VYGF33NRC Parts List Firebox Models FPVF33PRA and FPVF33NRA 101357-01 Accessories Wall Cabinet Mantel and Base Accessory with FireplacePerimeter Trim Not Shown Keep this Warranty Warranty InformationLimited Warranty VENT-FREE GAS Fireplace