Desa FPVF33PRA, VYGF33NRC installation manual Product Identification, Troubleshooting

Page 4

SAFETY INFORMATION

Continued

1.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

2.Do not place propane/LP supply tank(s) in- side any structure. Locate propane/LP supply tank(s) outdoors (propane/LP units only).

3.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

if you cannot reach your gas supplier, call the fire department

4.This fireplace shall not be installed in a bed- room or bathroom.

5.Do not use this fireplace as a wood-burning fireplace. Use only the logs provided with the fireplace.

6.Do not add extra logs or ornaments such as pine cones, vermiculite or rock wool. Using these added items can cause sooting. Do not add lava rock around base. Rock and debris could fall into the control area of fireplace.

7.To prevent the creation of soot, follow the instructions in Cleaning and Maintenance, page 24.

8.Before using furniture polish, wax, carpet cleaner or similar products, turn heater off. If heated, the vapors from these products may create a white powder residue within burner box or on adjacent walls or furniture.

9.This fireplace needs fresh air ventilation to run properly. This fireplace has an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the fireplace if enough fresh air is not available. See Air for Combustion and Ventila- tion, page 5. If fireplace keeps shutting off, see

Troubleshooting, page 25.

10.Do not run fireplace

where flammable liquids or vapors are used or stored

under dusty conditions

11.Do not use this fireplace to cook food or burn paper or other objects.

12.Do not use fireplace if any part has been exposed to or under water. Immediately call a qualified service technician to inspect the fireplace and to replace any part of the control

system and any gas control which has been under water.

13.Do not operate fireplace if any log is broken. Do not operate fireplace if a log is chipped (dime-sized or larger).

14.Turn fireplace off and let cool before servicing. Only a qualified service person should service and repair fireplace.

15.Operating fireplace above elevations of 4,500 feet could cause pilot outage.

16.To prevent performance problems in propane/LP units, do not use propane/LP fuel tanks of less than 100 lbs. capacity (propane/LP units only).

17.Provide adequate clearances around air openings.

Product

Identification

Log Set (VYGF shown)

Optional

Remote

Control

Control

 

 

Knobs

Piezo

 

 

Remote Selector

 

Ignitor

 

Switch (Optional)

 

 

Figure 1 - Log Base Assembly

Top Outer

Firebox

Casing

Support

Firebox

 

Hood

 

Screen

Assembly

Louver

Blower Assembly

 

(Optional)

Figure 2 - Fireplace

www.desatech.com113109-01C

Image 4
Contents VYGF33PRC, VYGF33NRC, FPVF33PRA millivolt FPVF33NRA MillivoltRemote-Ready Gas Fireplace Systems Patent PendingTable of Contents Safety InformationSafety Information Troubleshooting, Product IdentificationProduct Features Local CodesUnpacking Air For Combustion VentilationProviding Adequate Ventilation Determining FRESH-AIR Flow for Heater LocationUnusually Tight Construction Confined and Unconfined SpaceVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installation Installing HoodCheck GAS Type Electrical HookupInstallation Clearances Repeat steps 1 through 6 for other sideConventional Fireplace Installation Placing Hearth Base Accessory Against WallChecking Gas Connections, Models VYGF33PRB and VYGF33NRBConnecting Duplex Outlet Models FPVF33PRA and FPVF33NRAMantel Clearances for Built-In Installation Installing Gas Piping to Fireplace LocationInstallation Items Needed Connecting Fireplace to GAS Supply Accessories,Natural Gas From Gas Meter 5 W.C.** to Propane/LPChecking Gas Connections Checking GAS ConnectionsNatural Gas Pressure Testing Fireplace Gas Connections Test Pressures Equal To or Less Than Psig 3.5 kPaInstalling Logs Vygf Models OnlyInstalling Remote Receiver Unit Fpvf Models OnlyInstalling 9-Volt Batteries For Your Safety Read Before LightingInstalling 9-Volt Battery in Receiver Installing 9-Volt Battery in Hand-Held Remote Control UnitOperating Fireplace Lighting Instructions MANUAL Lighting Procedure To Turn OFF GAS To ApplianceOptional Hand-Held Remote OperationThermostat Series Model HRC200 Optional Blower OperationInspecting Burner Pilot Flame PatternBurner Flame Pattern Burner Primary AIR HolesBurner Injector Holder and Pilot Air Inlet Hole Cleaning MaintenanceLogs Observed Problem Possible Cause Remedy TroubleshootingIng and Maintenance, Maintenance, Diagram,See Cleaning and Mainte On windows Tilation air See Checking Gas Connec Gas leak. See WarningStalling Logs, Wiring Diagram SpecificationsReplacement Parts Technical ServiceIllustrated Parts Breakdown Models VYGF33PRC and VYGF33NRC ShownParts List Models FPVF33PRA and FPVF33NRA KEY Description Firebox Models VYGF33PRC and VYGF33NRC Parts List Firebox Models FPVF33PRA and FPVF33NRA 101357-01 Accessories Wall Cabinet Mantel and Base Accessory with FireplacePerimeter Trim Not Shown Keep this Warranty Warranty InformationLimited Warranty VENT-FREE GAS Fireplace