Desa FPVF33PRA Connecting Fireplace to GAS Supply, Natural Gas From Gas Meter 5 W.C.** to

Page 14
Propane/LP
Supply Tank

Installation

Continued

For propane/LP units, the installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11" and 14" of water. If you do not reduce incoming gas pres- sure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 21. Pointing the vent down protects it from freezing rain or sleet.

CAUTION: Use only new, black iron or steel pipe. Inter- nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas volume to fireplace. If pipe is too small, undue loss of volume will occur.

Installation must include an equipment shutoff valve, union and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from fireplace (see Figure 22).

IMPORTANT: Install equipment shutoff valve in an accessible location. The equipment shutoff valve is for turning on or shutting off the gas to the appliance.

Check your building codes for any special re- quirements for locating equipment shutoff valve to fireplaces.

Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged fireplace valves. Never use sealant on flare threads.

External

Regulator

Vent

Pointing

Down

Figure 21 - External Regulator on Propane/LP Supply Tank with Vent Pointing Down

WARNING: Use pipe joint sealant that is resistant to liquid petroleum (LP) gas.

We recommend that you install a sediment trap in supply line as shown in Figure 22. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and fireplace. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into fireplace gas controls. If sediment trap is not installed or is installed wrong, fireplace may not run properly.

CSA Design-Certified Equipment Shutoff Valve

With 1/8" NPT Tap*

Natural Gas From Gas Meter (5" W.C.** to

10.5" W.C. Pressure)

Propane/LP

From External

Regulator

3" Minimum

(11" W.C.** to

14" W.C.

 

 

Pressure)

Cap Pipe

Tee

Nipple

Joint

Sediment Trap

Figure 22 - Gas Connection

*Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See

Accessories, page 38.

** Minimum inlet pressure for purpose of input adjustment.

CONNECTING FIREPLACE TO GAS SUPPLY

Installation Items Needed

• 5/16" hex socket wrench or nut-driver

• Phillips screwdriver

• sealant (resistant to propane/LP gas, not pro- vided)

1.Remove fireplace screen. Remove two screws that hold fireplace screen in place for shipping. These screws are located near top of screen. Discard screws. Lift fireplace screen up and pull out to remove.

14

www.desatech.com

113109-01C

Image 14
Contents Remote-Ready Gas Fireplace Systems VYGF33PRC, VYGF33NRC, FPVF33PRA millivoltFPVF33NRA Millivolt Patent PendingTable of Contents Safety InformationSafety Information Troubleshooting, Product IdentificationUnpacking Product FeaturesLocal Codes Air For Combustion VentilationUnusually Tight Construction Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Confined and Unconfined SpaceVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Check GAS Type InstallationInstalling Hood Electrical HookupInstallation Clearances Repeat steps 1 through 6 for other sideConventional Fireplace Installation Placing Hearth Base Accessory Against WallChecking Gas Connections, Models VYGF33PRB and VYGF33NRBConnecting Duplex Outlet Models FPVF33PRA and FPVF33NRAInstallation Items Needed Installing Gas Piping to Fireplace LocationMantel Clearances for Built-In Installation Natural Gas From Gas Meter 5 W.C.** to Connecting Fireplace to GAS SupplyAccessories, Propane/LPNatural Gas Checking GAS ConnectionsChecking Gas Connections Pressure Testing Fireplace Gas Connections Test Pressures Equal To or Less Than Psig 3.5 kPaInstalling Logs Vygf Models OnlyInstalling Remote Receiver Unit Fpvf Models OnlyInstalling 9-Volt Battery in Receiver Installing 9-Volt BatteriesFor Your Safety Read Before Lighting Installing 9-Volt Battery in Hand-Held Remote Control UnitOperating Fireplace Lighting InstructionsOptional Hand-Held  MANUAL Lighting ProcedureTo Turn OFF GAS To Appliance Remote OperationThermostat Series Model HRC200 Optional Blower OperationBurner Flame Pattern Inspecting BurnerPilot Flame Pattern Burner Primary AIR HolesLogs Cleaning MaintenanceBurner Injector Holder and Pilot Air Inlet Hole Ing and Maintenance, TroubleshootingObserved Problem Possible Cause Remedy See Cleaning and Mainte Diagram,Maintenance, On windows Tilation air Stalling Logs, Gas leak. See WarningSee Checking Gas Connec Replacement Parts Wiring DiagramSpecifications Technical ServiceIllustrated Parts Breakdown Models VYGF33PRC and VYGF33NRC ShownParts List Models FPVF33PRA and FPVF33NRA KEY Description Firebox Models VYGF33PRC and VYGF33NRC Parts List Firebox Models FPVF33PRA and FPVF33NRA 101357-01 Accessories Perimeter Trim Not Shown Accessory with FireplaceWall Cabinet Mantel and Base Limited Warranty VENT-FREE GAS Fireplace Warranty InformationKeep this Warranty