Cleaning and

Maintenance

WARNING: Turn off fireplace and let cool before cleaning.

CAUTION: You must keep control areas, burner and cir- culating air passageways of fireplace clean. Inspect these areas of fireplace before each use. Have fireplace inspected yearly by a qualified service person. Fireplace may need more frequent cleaning due to excessive lint from carpeting, bedding material, pet hair, etc.

WARNING: Failure to keep the primary air opening(s) of the burner(s) clean may result in sooting and property damage.

Burner Injector Holder and Pilot Air Inlet Hole

The primary air inlet holes allow the proper amount of air to mix with the gas. This provides a clean burning flame. Keep these holes clear of dust, dirt, lint and pet hair. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We recommend that you clean the unit every three months during operation and have heater inspected yearly by a qualified service person.

We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 PSI. Your local computer store, hardware store or home center may carry compressed air in a can. You can use a vacuum cleaner in the blow position. If using com- pressed air in a can, please follow the directions on the can. If you don’t follow directions on the can, you could damage the pilot assembly.

1.Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes.

2.Inspect burner, pilot and primary air inlet holes on injector holder for dust and dirt (see Figures 48 and 49).

3.Blow air through the ports/slots and holes in the burner.

4.Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint or pet hair with a soft cloth or vacuum cleaner nozzle.

5.Blow air into the primary air holes on the injector holder.

6.In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4 above.

Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot as- sembly. There is a small pilot air inlet hole about 2" from where the pilot flame comes out of the pilot assembly (see Figure 49). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.

 

Injector Holder (May

 

Be Brass or Aluminum

Burner

Depending on Model)

Tube

 

Primary Air Inlet Holes (Shape of Holes May Vary by Model)

Figure 48 - Injector Holder On Outlet

Burner Tube

Ports/Slots

Burner

Tube

Pilot

Assembly

Pilot Air

Inlet Hole

Figure 49 - Pilot Inlet Air Hole

LOGS

If you remove logs for cleaning, refer to Install- ing Logs, page 17, to properly replace logs.

Replace log(s) if broken or chipped (dime-sized or larger).

24

www.desatech.com

113109-01C

Image 24
Contents VYGF33PRC, VYGF33NRC, FPVF33PRA millivolt FPVF33NRA MillivoltRemote-Ready Gas Fireplace Systems Patent PendingTable of Contents Safety InformationSafety Information Troubleshooting, Product IdentificationProduct Features Local CodesUnpacking Air For Combustion VentilationProviding Adequate Ventilation Determining FRESH-AIR Flow for Heater LocationUnusually Tight Construction Confined and Unconfined SpaceVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installation Installing HoodCheck GAS Type Electrical HookupInstallation Clearances Repeat steps 1 through 6 for other sideConventional Fireplace Installation Placing Hearth Base Accessory Against WallChecking Gas Connections, Models VYGF33PRB and VYGF33NRBConnecting Duplex Outlet Models FPVF33PRA and FPVF33NRAInstalling Gas Piping to Fireplace Location Mantel Clearances for Built-In InstallationInstallation Items Needed Connecting Fireplace to GAS Supply Accessories,Natural Gas From Gas Meter 5 W.C.** to Propane/LPChecking GAS Connections Checking Gas ConnectionsNatural Gas Pressure Testing Fireplace Gas Connections Test Pressures Equal To or Less Than Psig 3.5 kPaInstalling Logs Vygf Models OnlyInstalling Remote Receiver Unit Fpvf Models OnlyInstalling 9-Volt Batteries For Your Safety Read Before LightingInstalling 9-Volt Battery in Receiver Installing 9-Volt Battery in Hand-Held Remote Control UnitOperating Fireplace Lighting Instructions MANUAL Lighting Procedure To Turn OFF GAS To ApplianceOptional Hand-Held Remote OperationThermostat Series Model HRC200 Optional Blower OperationInspecting Burner Pilot Flame PatternBurner Flame Pattern Burner Primary AIR HolesCleaning Maintenance Burner Injector Holder and Pilot Air Inlet HoleLogs Troubleshooting Observed Problem Possible Cause RemedyIng and Maintenance, Diagram, Maintenance,See Cleaning and Mainte On windows Tilation air Gas leak. See Warning See Checking Gas ConnecStalling Logs, Wiring Diagram SpecificationsReplacement Parts Technical ServiceIllustrated Parts Breakdown Models VYGF33PRC and VYGF33NRC ShownParts List Models FPVF33PRA and FPVF33NRA KEY Description Firebox Models VYGF33PRC and VYGF33NRC Parts List Firebox Models FPVF33PRA and FPVF33NRA 101357-01 Accessories Accessory with Fireplace Wall Cabinet Mantel and BasePerimeter Trim Not Shown Warranty Information Keep this WarrantyLimited Warranty VENT-FREE GAS Fireplace