Desa VYGF33NRC, FPVF33PRA installation manual Operating Fireplace, Installing 9-Volt Batteries

Page 19

Installation

Continued

Installing 9-Volt Batteries

Two 9-volt batteries (not included) are required to operate this heater with the wireless hand held remote control set. Install one battery in the receiver and one in the hand-held remote control unit. Note: Only use alkaline batteries.

Installing 9-Volt Battery in Receiver

1. Locate back of receiver under front burner of heater.

2. Locate the battery clip mounted on the back of the receiver.

3. Slide a 9-volt battery through the clip.

4. Attach the terminal wires to the battery.

Remote

Terminal Wires

Receiver

 

Battery Clip

9-Volt Battery

Figure 36 - Installing Battery in Remote

Receiver

Installing 9-Volt Battery in Hand-Held

Remote Control Unit

1. Remove battery cover on back of remote control unit.

2. Attach terminal wires to the battery. Place battery into the battery housing.

3. Replace battery cover onto remote control unit.

Battery

Cover

Operating Fireplace

FOR YOUR SAFETY

READ BEFORE LIGHTING

WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result causing property damage, per- sonal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service tech- nician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

 

 

Remote

 

 

Control

Terminal

Battery

Unit

 

Wires

Housing

 

9-Volt Battery

Figure 37 - Installing Battery in Hand-

Held Remote Control Unit

113109-01C

www.desatech.com

19

Image 19
Contents Patent Pending VYGF33PRC, VYGF33NRC, FPVF33PRA millivoltFPVF33NRA Millivolt Remote-Ready Gas Fireplace SystemsSafety Information Table of ContentsSafety Information Product Identification Troubleshooting,Air For Combustion Ventilation Product FeaturesLocal Codes UnpackingConfined and Unconfined Space Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Unusually Tight ConstructionVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Electrical Hookup InstallationInstalling Hood Check GAS TypeRepeat steps 1 through 6 for other side Installation ClearancesPlacing Hearth Base Accessory Against Wall Conventional Fireplace InstallationModels VYGF33PRB and VYGF33NRB Checking Gas Connections,Models FPVF33PRA and FPVF33NRA Connecting Duplex OutletMantel Clearances for Built-In Installation Installing Gas Piping to Fireplace LocationInstallation Items Needed Propane/LP Connecting Fireplace to GAS SupplyAccessories, Natural Gas From Gas Meter 5 W.C.** toChecking Gas Connections Checking GAS ConnectionsNatural Gas Test Pressures Equal To or Less Than Psig 3.5 kPa Pressure Testing Fireplace Gas ConnectionsVygf Models Only Installing LogsFpvf Models Only Installing Remote Receiver UnitInstalling 9-Volt Battery in Hand-Held Remote Control Unit Installing 9-Volt BatteriesFor Your Safety Read Before Lighting Installing 9-Volt Battery in ReceiverLighting Instructions Operating FireplaceRemote Operation  MANUAL Lighting ProcedureTo Turn OFF GAS To Appliance Optional Hand-HeldOptional Blower Operation Thermostat Series Model HRC200Burner Primary AIR Holes Inspecting BurnerPilot Flame Pattern Burner Flame PatternBurner Injector Holder and Pilot Air Inlet Hole Cleaning MaintenanceLogs Observed Problem Possible Cause Remedy TroubleshootingIng and Maintenance, Maintenance, Diagram,See Cleaning and Mainte On windows Tilation air See Checking Gas Connec Gas leak. See WarningStalling Logs, Technical Service Wiring DiagramSpecifications Replacement PartsModels VYGF33PRC and VYGF33NRC Shown Illustrated Parts BreakdownParts List Models FPVF33PRA and FPVF33NRA KEY Description Firebox Models VYGF33PRC and VYGF33NRC Parts List Firebox Models FPVF33PRA and FPVF33NRA 101357-01 Accessories Wall Cabinet Mantel and Base Accessory with FireplacePerimeter Trim Not Shown Keep this Warranty Warranty InformationLimited Warranty VENT-FREE GAS Fireplace