Desa DVFH34P installation manual Vertical Termination Configurations, Venting with Two 90 Elbow s

Page 13

OWNER’S MANUAL

VENTING INSTALLATION

Continued

3.Lower the support box through the hole in the roof until the bottom of the box extends at least 2" below the ceiling (see Figure 22). Align the support box vertically and horizontally using a level. Temporarily tack the support box in place through the inside walls and into the roof sheathing.

4.Using tin snips, cut the support box from the top corners down to the roofline and fold the resulting flaps over the roof sheathing (see Figure 23). Apply a bead of non-hardening mastic around the top edges of the support box to make a seal between the box and the roof. Nail in place with roofing nails. Remove any combustible material that might be in- side of the support box.

5.Complete the cathedral ceiling instal- lation by following the same proce- dures outlined in steps 2 through 7 for Flat Ceiling Installation, page 12.

Level

Cathedral ceiling support box

2" minimum below finished ceiling

Vertical Termination Configurations

Figures 24 through 27 show four different configurations for vertical termination. All connections must be sealed with high temperature silicone sealant as specified in the second warning statement on page 7.

 

Venting with Two 90° Elbows

 

Vertical (V)

Horizontal (H1) +

 

 

Horizontal (H2)

 

5' min.

2' max.

 

6' min.

4' max.

 

7' min.

6' max.

FD60

8' min.

8' max.

60˚ Starter/

20' max.

8' max.

Adapter Required

Note: Install restrictor into 4" collar of stove as shown.

Figure 24 - Vertical Rigid Venting Configuration Using Two 90° Elbows with Two

Horizontal Runs

Cut hole 1/8" larger than support box when projected onto roofline

Figure 22 - Cathedral Ceiling Support Box Installation

Note: Install restrictor into 4" collar of stove as shown.

Venting with One 90° Elbow

FD60

Vertical (V)

Horizontal (H)

60˚ Starter/

5' min.

2' max.

Adapter

Required

6' min.

4' max.

 

7' min.

6' max.

 

8' min.

8' max.

 

20' max.

8' max.

Non-hardening Mastic under all edges of support box before nailing

Figure 23 - Installed Cathedral Ceiling

Figure 25 - Vertical Rigid Venting Configuration Using One 90° Elbow

 

Support Box

Continued

106394

13

Image 13
Contents For Your Safety What to do if YOU Smell GAS For Your SafetyNatural GAS Model DVFH34 PROPANE/LP GAS Model DVFH34P DVFH34, DVFH34P DIRECT-VENT Fireplace NATURAL/PROPANE/LP Safety InformationProduct Identification Product FeaturesLocal Codes Glossary TermsLocation and Space Requirements PRE-INSTALLATION PreparationClearances Framing and FinishingLocation of Vent Termination General VentingGeneral Venting Installation Precautions Venting InstallationInstallation Planning Installing Vent System in a ChaseTerminal into a wall or siding Installation for Horizontal TerminationRigid Vent Pipe Connections Horizontal Venting Horizontal Termination ConfigurationsVenting with Two 90 Elbows Flat Ceiling Installation Installation for Vertical TerminationCathedral Ceiling Installation Venting with Two 90 Elbow s Vertical Termination ConfigurationsVenting with One 90 Elbow Vertical Venting Vertical Rigid Venting Configuration With No Horizontal RunParts Lists for Venting Kits and Components High Altitude InstallationFMI Rigid Venting Number DescriptionInstalling Optional Blower Accessory Fireplace InstallationInstalling GA3700/DA3610TA Blowers Check GAS TypeIf your fireplace system is installed Installation Items Needed Installing GAS Piping to Fireplace LocationInstallation Items Needed Connecting Fireplace to GAS SupplyPressure Testing Gas Supply Piping System Checking GAS ConnectionsClose equipment shutoff valve see Fig- ure Pressure Testing Fireplace Gas ConnectionsInstalling Remote Receiver Installing Optional Wall Mounted Thermostat GWMT1REMOVING/REPLACING Glass Door Installing Optional Wall Mount Switch GWMS2Installing Rear Brick Panel and Retainer Brackets Installing Optional Brick Liner D8037AInstalling Log No Installing LOGS, Lava Rock and Glowing EmbersManual Lighting Procedure For Your Safety Read Before LightingOperating Fireplace Lighting InstructionsOptional Remote Operation Operating Optional GWMS2 Wall Mounted SwitchThermostat Control Operation Ghrc Series OperationPilot Assembly Operating Optional Blower AccessoryInspecting Burners Operating Optional GWMT1 Wall Mounted ThermostatGlass Door Cleaning and MaintenancePilot and Burners LogsObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Above Gas leak. See Warning statementWiring Diagram Replacement PartsService Hints Technical ServiceDVFH34 DVFH34P SpecificationsDVFH34 DVFH34P36 Illustrated Parts BreakdownDIRECT-VENT Fireplace DVFH34 DVFH34P Parts ListAccessories Receiver and HAND-HELD Remote Control KIT Ghrc Series DVFH34, DVFH34P DIRECT-VENT Fireplace NATURAL/PROPANE/LP 106394 Warranty Information