OWNER’S MANUAL
FIREPLACE INSTALLATION
Continued
CONNECTING FIREPLACE TO GAS SUPPLY
Installation Items Needed
•5/16" hex socket wrench or
•sealant (resistant to propane/LP gas, not provided)
1.Open lower louver door panel by gen- tly pulling forward.
2.Route flexible gas line (provided by installer) from equipment shutoff valve to fireplace. Route flexible gas supply line through one of the access holes on side of fireplace.
CHECKING GAS
CONNECTIONS
WARNING: Test all gas pip- ing and connections for leaks after installing or servicing. Cor- rect all leaks at once.
WARNING: Never use an open flame to check for a leak. Apply commercial leak test solution to all gas joints. Bubbles forming show a leak. Correct all leaks at once.
Pressure Testing Gas Supply Piping System
Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)
3.Pressurize supply piping system by ei- ther opening propane/LP supply tank valve for propane/LP gas fireplace or opening main gas valve located on or near gas meter for natural gas fireplace, or using compressed air.
4.Check all joints of gas supply piping system. Apply commercial leak test solution to all gas joints. Bubbles form- ing show a leak. Correct all leaks at once.
5.Reconnect fireplace and equipment shutoff valve to gas supply. Check re- connected fittings for leaks.
3.Attach flexible gas line from gas sup- ply to control valve (see Figure 35).
4.Check all gas connections for leaks. See Checking Gas Connections, pages 19 and 20.
1.Disconnect fireplace and its individual equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig (3.5 kPa) will damage fireplace gas regulator.
2.Cap off open end of gas pipe where equipment shutoff valve was connected.
To Gas Supply | Equipment Shutoff Valve |
| |
(Natural) |
|
To External Regulator (Propane/LP)
Control Valve
Flexible Gas Line from
Equipment Shutoff Valve
Provided by Installer
Figure 35 - Attaching Flexible Gas Line to Control Valve
Continued
106394 | 19 |