Desa installation manual Parts List, DIRECT-VENT Fireplace DVFH34 DVFH34P

Page 35

OWNER’S MANUAL

PARTS LIST

This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 32 of this manual.

DIRECT-VENT FIREPLACE

DVFH34

DVFH34P

KEY

 

 

 

NO.

PART NUMBER

DESCRIPTION

QTY.

 

 

 

 

1

104445-01

Top Outer Casing

1

2

105278-01

Outer Casing

1

3

105297-01

Bottom Outer Casing

1

4

104479-10BR

Firebox Assembly

1

5

M11084-26

Screw, Hex

50

6

M11084-46

Screw, Hex

8

7

105394-01

Louver, Extruded

2

8

104443-01

Firebox Support, Right

1

9

104486-01

Firebox Support, Left

1

10

104482-01

Switch Bracket

1

11

104483-01

Floor Mounting Bracket

2

12

104491-01

Relief Cover

1

13

104518-01

Relief Cover Gasket

1

14

104527-01

Relief Spring

2

15

104528-01

Relief Washer

2

16

104537-01

Valve Bracket

1

17

104496-01

SIT Valve, Natural

1

 

104496-02

SIT Valve, Propane/LP

1

18

104497-01

SIT Pilot, Natural

1

 

104497-02

SIT Pilot, Propane/LP

1

19

104498-01

Thermocouple

1

20

104499-01

Thermopile

1

21

104500-01

Ignitor

1

22

104501-01

Ignitor Bracket

1

23

104502-01

Ignitor Screw

1

24

104503-01

Ignitor Wire

1

25

104504-01

Burner, Natural

1

 

104504-02

Burner, Propane/LP

1

26

104506-01

Orifice, Natural

1

 

104506-02

Orifice, Propane/LP

1

 

 

 

 

KEY

 

 

 

 

 

 

 

 

NO.

PART NUMBER

DESCRIPTION

QTY.

 

 

 

 

 

27

104507-01

Brass Elbow

1

 

28

104508-01

Brass Fitting

2

 

29

104509-01

Aluminum Tubing Assy

1

 

30

104510-01

Pilot Tubing Assy

1

 

31

104954-01

Screw

3

 

32

104963-01

Washer

3

 

33

104955-01

Nut

3

 

34

107166-01

Log Set

 

 

34-1

107453-01

Rear Log

1

 

34-2

105772-02

Front Log

1

 

34-3

105772-03

Left Log

1

 

34-4

105772-04

Right Log

1

 

35

M10908-2

Screw

6

 

36

M12461-65

Screw

3

 

37

H5C4-20B

Bolt

2

 

38

NTC-4C

Locknut

2

 

39

M12461-26

Screw

4

 

40

104555-02CJ

Grate Assembly

1

 

41

105775-16

Glass Door Assy

1

 

42

104490-02CJ

Baffle

1

 

43

105450-01CK

Front Assembly

1

 

44

104615-02

Insulation

1

 

45

104313-01

Hinge, Pin - Left

1

 

46

104313-02

Hinge, Pin - Right

1

 

47

105325-01

Burner Baffle

1

 

48

105575-01

Wire Harness

1

 

 

 

 

 

 

PARTS AVAILABLE - NOT SHOWN

 

GA6060

Lava Rock

1

 

104529-01

Ember Material

1

 

 

 

 

106394

35

Image 35
Contents Natural GAS Model DVFH34 PROPANE/LP GAS Model DVFH34P For Your SafetyFor Your Safety What to do if YOU Smell GAS DVFH34, DVFH34P DIRECT-VENT Fireplace NATURAL/PROPANE/LP Safety InformationGlossary Terms Product FeaturesProduct Identification Local CodesFraming and Finishing PRE-INSTALLATION PreparationLocation and Space Requirements ClearancesLocation of Vent Termination General VentingGeneral Venting Installing Vent System in a Chase Venting InstallationInstallation Precautions Installation PlanningTerminal into a wall or siding Installation for Horizontal TerminationRigid Vent Pipe Connections Horizontal Venting Horizontal Termination ConfigurationsVenting with Two 90 Elbows Cathedral Ceiling Installation Installation for Vertical TerminationFlat Ceiling Installation Venting with One 90 Elbow Vertical Termination ConfigurationsVenting with Two 90 Elbow s Vertical Venting Vertical Rigid Venting Configuration With No Horizontal RunNumber Description High Altitude InstallationParts Lists for Venting Kits and Components FMI Rigid VentingCheck GAS Type Fireplace InstallationInstalling Optional Blower Accessory Installing GA3700/DA3610TA BlowersIf your fireplace system is installed Installation Items Needed Installing GAS Piping to Fireplace LocationChecking GAS Connections Connecting Fireplace to GAS SupplyInstallation Items Needed Pressure Testing Gas Supply Piping SystemClose equipment shutoff valve see Fig- ure Pressure Testing Fireplace Gas ConnectionsInstalling Remote Receiver Installing Optional Wall Mounted Thermostat GWMT1REMOVING/REPLACING Glass Door Installing Optional Wall Mount Switch GWMS2Installing Rear Brick Panel and Retainer Brackets Installing Optional Brick Liner D8037AInstalling Log No Installing LOGS, Lava Rock and Glowing EmbersLighting Instructions For Your Safety Read Before LightingManual Lighting Procedure Operating FireplaceGhrc Series Operation Operating Optional GWMS2 Wall Mounted SwitchOptional Remote Operation Thermostat Control OperationOperating Optional GWMT1 Wall Mounted Thermostat Operating Optional Blower AccessoryPilot Assembly Inspecting BurnersLogs Cleaning and MaintenanceGlass Door Pilot and BurnersObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Above Gas leak. See Warning statementTechnical Service Replacement PartsWiring Diagram Service HintsDVFH34 DVFH34P SpecificationsDVFH34 DVFH34P36 Illustrated Parts BreakdownDIRECT-VENT Fireplace DVFH34 DVFH34P Parts ListAccessories Receiver and HAND-HELD Remote Control KIT Ghrc Series DVFH34, DVFH34P DIRECT-VENT Fireplace NATURAL/PROPANE/LP 106394 Warranty Information